PDF44G0800D3DJ
PDF44G0800D3DJ
Eaton - Molded Case
PDF44G0800D3DJ, Cutler Hammer, Eaton, Power Defense, type , 3PH, 4P, 600V, 800A, 35kA@480V, Feed-Thru, line & load side lug terminals, complete with PXR20D trip with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, relays, modbus and CAM, Solid State electronic, molded case circuit breakers; globally rated, 100% UL rated
From Get Price
Limited Stock
SHB2G496K
SHB2G496K
General Electric - Insulated Case
SHB2G496K, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 1600A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, full metering, modbus communication, relays & ZSI features and 600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0322NMNCNYNAMAX
MDN4083LEA0322NMNCNYNAMAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNCNYNAMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SSD2G4E4P
SSD2G4E4P
General Electric - Insulated Case
SSD2G4E4P, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 1600A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT & modbus communication features and 1000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0222NMNE4ENYCAX
MDN4083LEA0222NMNE4ENYCAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNE4ENYCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNE4YNHNCX
MDN4083LEA0622NMNE4YNHNCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNE4YNHNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0822NMNF2YNRCWX
MDN4083LEA0822NMNF2YNRCWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNF2YNRCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
NEG1C070
NEG1C070
Siemens - Molded Case
NEG1C070, Siemens, VL Series, type , 1P, 1PH, 70A, 600V, 35kA@480V, standard interrupting capacity, suitable for reverse feed applications, Bolt-On, 50ºC calibrated, complete with LI - Long-Time and Instantaneous trip functions, lugs not included, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
QC4015HEH
QC4015HEH
Westinghouse - Molded Case
QC4015HEH, Cutler Hammer, Westinghouse, Quicklag, type , 4P, 3PH, 15A, 240V, 10kA@240V, extra high interrupting capacity, 40°C, Feed-Thru, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
SSD1G1B6A
SSD1G1B6A
General Electric - Insulated Case
SSD1G1B6A, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering, RELT & modbus communication features and 100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0322NMNG4ENRNSX
MDN4083LEA0322NMNG4ENRNSX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNG4ENRNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
WLS2F316DT
WLS2F316DT
Siemens - Insulated Case
WLS2F316DT, Siemens, WL Series, type , frame size II, fixed mount, 3P, 3PH, 1600A, 600V, 65kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with solid state ETU755 programmer + WLGFA76 ground fault module, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions and 300A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNCNENRNSX
MDN4083LEA0622NMNCNENRNSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNCNENRNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SHB5G8L21
SHB5G8L21
General Electric - Insulated Case
SHB5G8L21, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, back connected, 3000A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, current metering, RELT & ZSI features and 2500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0722NMNH2YNANSX
MDN4083LEA0722NMNH2YNANSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNH2YNANSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0322NMNC2YHNDSX
MDN4083LEA0322NMNC2YHNDSX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNC2YHNDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
430042
430042
General Electric - Molded Case
430042 General Electric Record Plus, type , FDH160 frame, FDH436TD050ED, 4P, 3PH, 50A, 690V, 80kA@415V, Feed-Thru, complete with interchangeable LTMD trip, DIN rail mounted, LI - Long-Time and Instantaneous trip functions, selective Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
SHD3G6N3R
SHD3G6N3R
General Electric - Insulated Case
SHD3G6N3R, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering, modbus communication & ZSI features and 1200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
PEAC3ATTR0090
PEAC3ATTR0090
General Electric - Molded Case
PEAC3ATTR0090, General Electric, GuardEon, type , 3PH, 3P, 600V, 90A, 25kA@480V, front connection/Feed-Thru, toggle mechanism, complete with LTM interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers; meet UL, cUL, IEC, CE, CCC requirements
From Get Price
Limited Stock
SHD1G3A4J
SHD1G3A4J
General Electric - Insulated Case
SHD1G3A4J, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering & RELT features and 500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0722NMNXNYNKMAX
MDN4083LEA0722NMNXNYNKMAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNXNYNKMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
JXD23M300L
JXD23M300L
Siemens - Molded Case
JXD23M300L, Siemens, Sentron Series, type , 3P, 3PH, 300A, 240V, 65kA@240V, standard interrupting capacity, 50ºC, Feed-Thru, complete with non-interchangeable trip unit and line & load side lug terminals, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
SHF1G3C3F
SHF1G3C3F
General Electric - Insulated Case
SHF1G3C3F, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering & modbus communication features and 300A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0522NMNN2YNRDSX
MDN4083LEA0522NMNN2YNRDSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNN2YNRDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price