1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
8739SCA8V02S
8739SCA8V02S
Square D - Motor Starter
8739SCA8V02S, Square D, Class 8739, type , full voltage reversing motor starter with HLL 20A thermal magnetic circuit breaker, 3P, 3PH, 7.5HP @ 600V, 600V with 120V 60Hz/110V 50Hz coil, NEMA size 1, includes NEMA 12/3R dust-tight industrial use enclosure without external reset
From Get Price
Limited Stock
EELCL310200SB2
EELCL310200SB2
Cutler Hammer - Mounting Hardware
EELCL310200SB2, Cutler Hammer, EE Series, mounting hardware, plug-in mounting module, rated for 200A, ABC phase connection, 120V max, Copper, Single Branch mounting style, suitable for use with LCL circuit breaker frames and EP panelboards; these modules are obsolete, however we still stock them
From Get Price
Limited Stock
BL3EEV44A9CXXXXXAM
BL3EEV44A9CXXXXXAM
Square D - Insulated Case
BL3EEV44A9CXXXXXAM / <strong>NW16H</strong>, Square D, insulated case circuit breaker, Masterpact NW, type , manual charge, 1600A, 600V, 100kA@480V, Bolt-On/fixed, Micrologic 6.0A with LSIG functions, 8A/8B aux switch, no PCM, with ready to close switch, padlock & kirk lock, insulated case circuit breakers
From Get Price
Limited Stock
RP6D40A200
RP6D40A200
Cutler Hammer - Rating Plug
RP6D40A200, Cutler Hammer, DS Series, type , replacement rating plug, rated for 2000A, 4000A sensor rating, 50/60 Hz, suitable for use with DS,DSL,DSII,DSLII molded case circuit breaker frame types, for use with Digitrip RMS,Digitrip OPTIM trip units & circuit breakers
From Get Price
Limited Stock
LT2400TA
LT2400TA
Cutler Hammer - Trip Units And Programmers
LT2400TA, Cutler Hammer, Series C, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 400A, 2P, suitable for IEC rated Series C- LW,HLW,LWC molded case circuit breaker frame types, adjustable Thermal Magnetic trip units & circuit breakers
From Get Price
Limited Stock
XT2SQ4125PFF000XXX
XT2SQ4125PFF000XXX
ABB - Molded Case
XT2SQ4125PFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 4-Pole, 125A, 600V, 22kA@600V, Ekip Touch LSI, UL 100% Rated, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No
From Get Price
Limited Stock
FGTKA4N0630
FGTKA4N0630
General Electric - Trip Units And Programmers
FGTKA4N0630, General Electric, Record Plus, modular electronic interchangeable trip (SMR2) without rating plug, LI - Long-Time and Instantaneous trip functions, rated for 630A, 600V, 4P, suitable for FG630 frame- FGN,FGH,FGL molded case circuit breaker frame types, Thermal Magnetic trip units and programmers
From Get Price
Limited Stock
8739SEG3V08H30
8739SEG3V08H30
Square D - Motor Starter
8739SEG3V08H30, Square D, Class 8739, type , full voltage reversing motor starter with HLL 100A thermal magnetic circuit breaker, 3P, 3PH, 40HP @ 480V, 50HP @ 600V, 600V with 208V 60Hz coil, NEMA size 3, includes NEMA 1 general purpose enclosure, Motor Logic SSOLR Class 10/20
From Get Price
Limited Stock
JGX425032GCH08
JGX425032GCH08
Cutler Hammer - Molded Case
JGX425032GCH08, Cutler Hammer, Series G, type , 4P, 3PH, 250A, 600V, 200kA@480V, current limiting, UL listed for Marine applications 40°C, Feed-Thru, complete breaker with 310+ electronic, non-interchangeable trip unit and line & load side lug terminals, Solid State, molded case circuit breakers
From Get Price
Limited Stock
452D371G14
452D371G14
Eaton - Trip Units And Programmers
452D371G14, Eaton, Naval, Thermal Magnetic trip units and programmers, type -A250, 2P, 160A, 500Vac/250Vdc, 1950-3900 instantaneous trip setting, LI - Long-Time and Instantaneous trip functions, suitable for use with AQB-A250 circuit breakers for naval shipboard use and generator circuit breaker application
From Get Price
Limited Stock
XT2VQ4060PFF000XXX
XT2VQ4060PFF000XXX
ABB - Molded Case
XT2VQ4060PFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 4-Pole, 60A, 600V, 42kA@600V, Ekip Touch LSI, UL 100% Rated, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No
From Get Price
Limited Stock
8739SFW4V08
8739SFW4V08
Square D - Motor Starter
8739SFW4V08, Square D, Class 8739, type , full voltage reversing motor starter with JJL & JLL 250A thermal magnetic circuit breaker, 3P, 3PH, 100HP @ 480V, 100HP @ 600V, 600V with 208V 60Hz coil, NEMA size 4, includes NEMA 4 & 4X watertight and dust-tight stainless steel enclosure
From Get Price
In Stock
PD6S40A250
PD6S40A250
Cutler Hammer - Rating Plug
PD6S40A250, Cutler Hammer, SPB Series, type , replacement Digitrip RMS rating plug, rated for 2500A, 4000A sensor rating, 50/60Hz, style number 2613D09G31, suitable for use with SPB molded case circuit breaker frames, for use with Digitrip RMS thermal magnetic trip units & circuit breakers
From $236.59
Limited Stock
JGX316036GH08
JGX316036GH08
Cutler Hammer - Molded Case
JGX316036GH08, Cutler Hammer, Series G, type , 3P, 3PH, 160A, 600V, 200kA@480V, current limiting, UL listed for Marine applications 40°C, Feed-Thru, complete breaker with 310+ electronic, non-interchangeable trip unit and line & load side lug terminals, Solid State, molded case circuit breakers
From Get Price
Limited Stock
XT2LQ3060SFF000XXX
XT2LQ3060SFF000XXX
ABB - Molded Case
XT2LQ3060SFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 3-Pole, 60A, 600V, 35kA@600V, Ekip Touch Measuring LSIG, UL 100% Rated, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No
From Get Price
Limited Stock
XT2SQ4060UFF000XXX
XT2SQ4060UFF000XXX
ABB - Molded Case
XT2SQ4060UFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 4-Pole, 60A, 600V, 22kA@600V, Ekip Hi-Touch LSIG, UL 100% Rated, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No
From Get Price
Limited Stock
8739SDW11V03
8739SDW11V03
Square D - Motor Starter
8739SDW11V03, Square D, Class 8739, type , full voltage reversing motor starter with HLL 60A thermal magnetic circuit breaker, 3P, 3PH, 20HP @ 480V, 25HP @ 600V, 600V with 240V 60Hz/220V 50Hz coil, NEMA size 2, includes NEMA 4X watertight and dust-tight polyester enclosure
From Get Price
Limited Stock
8739SDA18V02S
8739SDA18V02S
Square D - Motor Starter
8739SDA18V02S, Square D, Class 8739, type , full voltage reversing motor starter with HLL 35A thermal magnetic circuit breaker, 3P, 3PH, 15HP @ 600V, 600V with 120V 60Hz/110V 50Hz coil, NEMA size 2, includes NEMA 12/3R dust-tight industrial use enclosure with external reset
From Get Price
Limited Stock
KM3400TJ5M
KM3400TJ5M
Cutler Hammer - Trip Units And Programmers
KM3400TJ5M, Cutler Hammer, Series C mining, type , 3P, interchangeable trip, I - Instantaneous trip function, rated for 400A, magnetic trip range 875-1750A, suitable for 400A- KDM,KDCM mining service Magnetic Only molded case circuit breaker frame types, Magnetic Only trip units & circuit breakers
From Get Price
In Stock
PD6S21A120
PD6S21A120
Cutler Hammer - Rating Plug
PD6S21A120, Cutler Hammer, SPB Series, type , replacement Digitrip RMS rating plug, rated for 1200A, 2000A sensor rating, 50/60Hz, style number 2613D09G18, suitable for use with SPB molded case circuit breaker frames, for use with Digitrip RMS thermal magnetic trip units & circuit breakers
From $235.39
Limited Stock
8539SDG44S8V03
8539SDG44S8V03
Square D - Motor Starter
8539SDG44S8V03, Square D, Class 8539, combination non-reversing motor starter, NEMA size 2, supplied with MAG-GARD GJL36100-M18 circuit breaker and NEMA type 1 oversized enclosure, 3P, 3PH, 600V, 15HP @ 240V, complete with 240V coil, suitable for use with Class 8539 motor control systems
From Get Price
Limited Stock
WHM2R12X
WHM2R12X
Cutler Hammer - Part And Accessory
WHM2R12X, Cutler Hammer, Series C, part and accessory, IEC rated Operating Handles, IEC IP66, rotary through-the-door handle mechanism, includes handle, mechanism, shaft & support brace/bracket, 12-inch shaft length, suitable for use with JDB,JD,HJD,JDC molded case circuit breaker frames
From Get Price
Limited Stock
KM3350T
KM3350T
Cutler Hammer - Trip Units And Programmers
KM3350T, Cutler Hammer, Series C mining, type , 3P, interchangeable trip, LI - Long-Time and Instantaneous trip functions, rated for 350A, magnetic trip range 1750-3500A, suitable for 400A- KDM,KDCM mining service molded case circuit breaker frame types, Thermal Magnetic trip units & circuit breakers
From Get Price
Limited Stock
8739SDA11V08
8739SDA11V08
Square D - Motor Starter
8739SDA11V08, Square D, Class 8739, type , full voltage reversing motor starter with HLL 60A thermal magnetic circuit breaker, 3P, 3PH, 20HP @ 480V, 25HP @ 600V, 600V with 208V 60Hz coil, NEMA size 2, includes NEMA 12/3R dust-tight industrial use enclosure with external reset
From Get Price