PDG23N0100E2WL
Eaton - Molded Case
PDG23N0100E2WL, Eaton, Cutler Hammer, Power Defense, type , 3PH, 3P, 600V, 100A, 85kA@480V, Bolt-On, load side lug terminals, complete with Xpert Release PXR20 trip with LSIZ - Long-Time, Short-Time, Instantaneous and ZSI trip functions, relays and modbus, Solid State electronic, molded case circuit breakers; globally rated
From Get Price

MDN4083LEA0622NMNJ2ENCNCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNJ2ENCNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0522NMNNNNNYMAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNNNNNYMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price

MDN4083LEA0422NMNHNENKDSX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNHNENKDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0222NMNHNENCNPX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNHNENCNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

SPB150-3P-2000A-EO-DO-LSI
Cutler Hammer - Insulated Case
SPB150-3P-2000A-EO-DO-LSI, Cutler Hammer, Systems Pow-R, type , larger frame size/non-compact frame size, 3P, 3PH, 2000A, 600V, 150kA@480V, standard interrupting capacity, Draw-Out, electrically operated, available with Pow-R Trip, Pow-R Trip 7, Digitrip RMS 510, 610, 810, 910, Digitrip OPTIM 750 and 1050, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price

MDN4083LEA0422NMNH2ENKMPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNH2ENKMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0322NMNGNENLNCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNGNENLNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & Castell key interlock, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0322NMNJNYNNNPX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNJNYNNNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassette, without shutters, pre-wired
From Get Price

MDN4083LEA0422NMNK2NHNDPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNK2NHNDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

XT4VQ3225UFF000XXX
ABB - Molded Case
XT4VQ3225UFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 3-Pole, 225A, 600V, 65kA@600V, Ekip Hi-Touch LSIG, UL 100% Rated, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No - 1SDA07211R1 global reference
From Get Price

MDN4083LEA0122NMNNNEPKDSX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNNNEPKDSX, Cutler Hammer, Magnum DS, type , drawout mounted, factory installed padlock pushbutton cover, narrow plastic frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, latch check switch for external wiring, lower terminal voltage connection, Kirk keylock, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters and unwired
From Get Price

MDN4083LEA0822NMNG4ECKDPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNG4ECKDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, 4A/4B auxiliary switch, latch check switch for external wiring, load side lug terminals & Kirk keylock, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

SSD1G3F9N
General Electric - Insulated Case
SSD1G3F9N, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, full metering & modbus communication features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

JGE316036GVH09
Cutler Hammer - Molded Case
JGE316036GVH09, Cutler Hammer, Series G, type , 3P, 3PH, 160A, 600V, 25kA@480V, standard interrupting capacity, for Naval applications 50°C, not UL listed, Feed-Thru, complete breaker with 310+ electronic, non-interchangeable trip unit and line & load side lug terminals, Solid State, molded case circuit breakers
From Get Price

MDN4083LEA0222NMNFNYNLCCX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNFNYNLCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch, Castell key interlock & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0422NMNA2NNHCPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNA2NNHCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0222NMNANENRMSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNANENRMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0522NMNH2YNHDAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNH2YNHDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

MDN4083LEA0122NMNN2ENCCSX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNN2ENCCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0822NMNA2NNACPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNA2NNACPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0122NMNF2NNHDPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNF2NNHDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0522NMNE2ENHCAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNE2ENHCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

MDN4083LEA0122NMNN2NNNCPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNN2NNNCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired