- Home /
breaker
962,938 Results
Refine Results
In Stock
Subcategory
SORT BY

MDN4083LEA0222NMNRNENLCCX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNRNENLCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0722NMNN4YNCCSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNN4YNCCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0122NMNG4NNCNCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNG4NNCNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Castell keylock, mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0322NMNCNNNHNWX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNCNNNHNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0422NMNA4ENHMWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNA4ENHMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0522NMNRNNNYMCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNRNNNYMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0822NMNG2NNKMSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNG2NNKMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0722NMNC4NNNCCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNC4NNNCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0522NMNH4NNHCAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNH4NNHCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

MDN4083LEA0622NMNFNNMNNCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNFNNMNNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed metal padlockable pushbutton cover, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0722NMNX4ENHMPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNX4ENHMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0522NMNFNYNYNPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNFNYNYNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

HGA36150U43XAABKUPYP
Square D - Molded Case
HGA36150U43XAABKUPYP, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 150A, 600V, 35kA@480V, high interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse connection, micrologic ammeter 5.2A non-interchangeable trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, complete with 1A/1B aux switch, alarm switch and overcurrent trip switch, low-level, 48 VDC under voltage release (UVR), "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $4,722.27

MDN4083LEA0122NMNENENYCSX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNENENYCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

HGA36150U33XABBHSVYP
Square D - Molded Case
HGA36150U33XABBHSVYP, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 150A, 600V, 35kA@480V, high interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse connection, can be used for 2P applications, micrologic standard 3.2S non-interchangeable trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, complete with 2A/2B aux switch, alarm switch low-level, 60 VDC shunt trip, "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $3,632.37

MDN4083LEA0122NMNXNENCDPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNXNENCDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0722NMNC4ENYNSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNC4ENYNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0522NMNANYNRMWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNANYNRMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0122NMNH2YNHDAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNH2YNHDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

MDN4083LEA0322NMNN4YNCDSX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNN4YNCDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0122NMNX4YNCDAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNX4YNCDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

MDN4083LEA0722NMNH2YNKCAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNH2YNKCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

HGA36060U33XAFBHUD
Square D - Molded Case
HGA36060U33XAFBHUD, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 60A, 600V, 35kA@480V, high interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse connection, can be used for 2P applications, micrologic standard 3.2S non-interchangeable trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, complete with 2A/2B low-level aux switch, alarm switch low-level, 208/277 VAC under voltage release (UVR), molded case circuit breakers
From $2,165.73

MDN4083LEA0522NMNANNNLMWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNANNNLMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price