- Home /
square d breaker
961,107 Results
Refine Results
In Stock
Subcategory
SORT BY

SSD1G361N
General Electric - Insulated Case
SSD1G361N, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, modbus communication & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

MDN4083LEA0122NMNXNEMNMPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNXNEMNMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed metal padlockable pushbutton cover, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

WLL3F350ZE
Siemens - Insulated Case
WLL3F350ZE, Siemens, WL Series, type , frame size III, fixed mount, 3P, 3PH, 5000A, 600V, 100kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with solid state ETU745 programmer + WLGFA48, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions and 4000A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price

REF3A060L
Miami Breaker - Molded Case
REF3A060L, Miami Breaker, REF Series, type , 3P, 3PH, 60A, 600V, 14kA@480V, standard interrupting capacity, Feed-Thru, complete with I - Instantaneous protection only and line & load side lug terminals, standard magnetic range, MCP, motor circuit protectors, Magnetic Only, molded case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price

MDN4083LEA0622NMNGNENLMAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNGNENLMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & Castell key interock, Solid State, low voltage power insulated case circuit breakers
From Get Price

WLL2F316NL
Siemens - Insulated Case
WLL2F316NL, Siemens, WL Series, type , frame size II, fixed mount, 3P, 3PH, 1600A, 600V, 100kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with solid state ETU748 programmer + WLGFA48 ground fault module, LSGA - Long-Time, Short-Time and Ground Fault Alarm trip functions and 800A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price

PDF33GH250D4WN
Cutler Hammer - Molded Case
PDF33GH250D4WN, Eaton, Cutler Hammer, Power Defense, type , 3PH, 3P, 600V, 250A, High Override, 35kA@480V, 100% UL, Bolt-On, no lug terminals, complete with PXR20D ARMS trip with LSI - Long-Time, Short-Time and Instantaneous trip functions and Modbus RTU, ZSI & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price

SHF1G2K3C
General Electric - Insulated Case
SHF1G2K3C, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering & ZSI features and 200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

EEEDH420175SB2
Cutler Hammer - Mounting Hardware
EEEDH420175SB2, Cutler Hammer, EE Series, mounting hardware, plug-in mounting module, rated for 175A, ABL or BCR phase connection, 240V max, Copper, Single Branch mounting style, suitable for use with ED,EDH,EDC,JD,HJD,JDC circuit breaker frames and EP panelboards; these modules are obsolete, however we still stock them
From Get Price

HDX4B125L
Siemens - Molded Case
HDX4B125L, Siemens, VL Series, type , 4P, 3PH, 125A, 600V, 65kA@480V, high interrupting capacity, 40ºC, Feed-Thru, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, suitable for reverse fed applications, Thermal Magnetic molded case circuit breakers
From Get Price

SSD4G751W
General Electric - Insulated Case
SSD4G751W, General Electric, Power Break II, type , 3P, 3PH, 600V, 2500A current sensor rating, 100kA@480V, standard interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, RELT, modbus communication & ZSI features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

E4H-A36-3P-2500A-BO-MO-LSIG
ABB - Insulated Case
E4H-A36-3P-2500A-BO-MO-LSIG, ABB, EMax, type , 3P, 3PH, 3600A frame, 2500A rating plug, 600V, 85kA@480V, fixed/Bolt-On, manually operated, Solid State electronic with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price

MDN4083LEA0322NMNK2ENANAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNK2ENANAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price

FGL36DP250LF
General Electric - Molded Case
FGL36DP250LF, General Electric, Record Plus, type , FG600 frame, 3P, 3PH, 250A current sensor, 480V, 150kA@480V, high interrupting capacity, Bolt-On, complete with PremEon S electronic trip, I - Instantaneous protection only, Magnetic Only plus ground fault, MCP motor circuit protectors, molded case circuit breakers
From Get Price

MDN4083LEA0322NMNF2YNCMCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNF2YNCMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

CRDC316T56W
Eaton - Molded Case
CRDC316T56W, Westinghouse, Cutler Hammer, Eaton, Series C, type , 3P, 3PH, 1600A, 600V, 100kA@480V, high interrupting capacity, Bolt-On, 100% rated, complete with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, lugs and rating plug not included, Digitrip RMS 510, Solid State electronic, molded case circuit breakers
From Get Price

MDN4083LEA0222NMNE4YNHCAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNE4YNHCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

SHMD6A600LIGH
Siemens - Molded Case
SHMD6A600LIGH, Siemens, Sentron Series, type , 3PH, 3P, 600V, 600A, 65kA@480V, Feed-Thru connection, 100% rated, complete with Sensitrip IV series trip unit with LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breakers
From Get Price

MDN4083LEA0122NNAG4YNNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NNAG4YNNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, electrically operated with 110-120Vac motor operator and 110-127Vac/dc spring release device (SRD), factory installed 32Vdc UVR, 4A/4B auxiliary switch, mechanical trip indicator & OTS switch, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price

XT7HU310DQFF000XXX
ABB - Molded Case
XT7HU310DQFF000XXX, ABB, SACE Tmax XT, type , 3PH, 3P, 600V, 1000A, 65kA@480V, , front terminals, complete with Ekip Touch trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Ekip Touch LSIG, molded case circuit breakers; 1SDA102960R1 global reference
From Get Price

MDN4083LEA0522NMNJ4NNHCCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNJ4NNHCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

EEHND211000TB2
Cutler Hammer - Mounting Hardware
EEHND211000TB2, Cutler Hammer, EE Series, mounting hardware, plug-in mounting module, rated for 1000A, AC phase connection, 120V max, Copper, Dual/Twin Branch mounting style, suitable for use with ND,HND,NDC circuit breaker frames and EP panelboards; these modules are obsolete, however we still stock them
From Get Price

MDN4083LEA0122HMNC4NNNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122HMNC4NNNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, factory installed 48Vdc shunt trip (ST), 24Vdc UVR, 4A/4B auxiliary switch & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price

MDN4083LEA0422NMNF2ENYDPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNF2ENYDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price