- Home /
square d breaker
961,107 Results
Refine Results
In Stock
Subcategory
SORT BY

MDN4083LEA0722NMNNNECNMAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNNNECNMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price

SHD4G623P
General Electric - Insulated Case
SHD4G623P, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering, RELT, modbus communcation & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

RCA
Cutler Hammer - Enclosure
RCA, Cutler Hammer, Westinghouse, NEMA 3R enclosure, rain-tight, 125-225A, 240V, suitable for use with CA,CAH frame circuit breakers
From Get Price

XT4LU3250CFF000XXX
ABB - Molded Case
XT4LU3250CFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 3-Pole, 250A, 600V, 50kA@600V, Ekip DIP LIG, UL Standard, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No - 1SDA07211R1 global reference
From Get Price

LAB32250SMW
Westinghouse - Molded Case
LAB32250SMW, Westinghouse, LAB Series, type , 3P, 3PH, 400A, 600V, 30kA@480V, standard interrupting capacity, Bolt-On, front adjustable, magnetic trip range 1125-2250A, complete with I - Instantaneous only trip function and Saf-T-Vue window, lugs not included, Magnetic Only molded case circuit breakers; these breakers are obsolete, however we do still stock them
From $1,882.18

XT2SU4125RFF000XXX
ABB - Molded Case
XT2SU4125RFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 4-Pole, 125A, 600V, 22kA@600V, Ekip Touch Measuring LSI, UL Standard, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No - 1SDA07211R1 global reference
From Get Price

JT4200TV
Cutler Hammer - Trip Units And Programmers
JT4200TV, Cutler Hammer, Series C, type , trip units and programmers, interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 200A, 50°C, suitable for HJDDC,JD,HJD,JDC molded case circuit breaker frame types, Thermal Magnetic trip units & circuit breakers
From Get Price

SGHH3604L7L6
General Electric - Molded Case
SGHH3604L7L6 General Electric Spectra Series, type , 3P, 3PH, 400A, 600V, 35kA@480V, standard interrupting capacity, 100% rated, UL listed, suitable for reverse fed applications, complete with microEntelliGuard trip unit with LSI-CP, LSI - Long-Time, Short-Time and Instantaneous and ZSI, zone selective interlocking & RELT, reduced energy let-through trip functions and advanced metering, modbus & waveform capture communication features, Solid State electronic, molded case circuit breakers
From Get Price

MDN4083LEA0622NMNR2ENCCWX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNR2ENCCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

EH2H090
Siemens - Molded Case
EH2H090, Siemens, ITE, EH Series, type , 2P, 1PH, 90A, 480V, 14kA@480V, standard interrupting capacity, Bolt-On, complete with I - Instantaneous protection only and load side lug terminals, high magnetic range, MCP, motor circuit protectors, Magnetic Only, molded case circuit breakers
From Get Price

MDN4083LEA0622NMNK4ECNDSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNK4ECNDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

THK9VV4612S
General Electric - Molded Case
THK9VV4612S General Electric MicroVersaTrip, type , K1200 frame type, 3P, 3PH, 1200A, 600V, 50kA@480V, 100% rated, high interrupting capacity, Bolt-On, complete with 9-function MVT, LSI - Long-Time, Short-Time and Instantaneous trip functions, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price

SSF2G4X8N
General Electric - Insulated Case
SSF2G4X8N, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 1600A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

WLS1F320LC
Siemens - Insulated Case
WLS1F320LC, Siemens, WL Series, type , frame size I, fixed mount, 3P, 3PH, 2000A, 600V, 65kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with solid state ETU745 programmer with LSI - Long-Time, Short-Time and Instantaneous trip functions and 630A rating plugs, Solid State electronic, low voltage insulated case circuit breakers
From Get Price

MPA31F0802310
General Electric - Insulated Case
MPA31F0802310, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, 48V dc motor operator, 110/130V dc/ac closing coil and 24/30V dc shunt trip, 3P, 3PH, 800A, 690V, 50kA@415V, Bolt-On, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers
From Get Price

MDN4083LEA0622NMNR4YCNCAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNR4YCNCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

PEBH4ATEK0025
General Electric - Molded Case
PEBH4ATEK0025, General Electric, GuardEon, type , 3PH, 4P, 600V, 8-25A, 100kA@480V, 100% UL rated, front connection/Feed-Thru, toggle mechanism, complete with PremEon G advanced metering interchangeable trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breakers; meet UL, cUL, IEC, CE, CCC requirements
From Get Price

MDN4083LEA0122NMNN4NCNMCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNN4NCNMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

BQDST48
Siemens - Shunt Trip
BQDST48, Siemens, BQD Series, type , shunt trip, 48VDC, suitable for use with BQD frame molded case circuit breakers
From Get Price

SHB1G1X8B
General Electric - Insulated Case
SHB1G1X8B, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering features and 150A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

MDN4083LEA0722NMNX4NNNMWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNX4NNNMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

46512
Merlin Gerin - Trip Units And Programmers
46512, Merlin Gerin, Schneider Electric, Compact, trip units and programmers, type , 400 - 1200A, 600V, Solid State electronic protection, LSI - Long-Time, Short-Time and Instantaneous trip functions, 3 pole trip unit, STR55UE, E9, with residual type ground fault protection, suitable for use with CK,CKAX,CKAE,CKHX,CKHE,CKIX,CKAF,CKAL frame molded case circuit breakers, cannot be used in a draw-out assembly
From Get Price

MDN4083LEA0622NMNC2ENYNWX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNC2ENYNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0322NMNJNNNNNSX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNJNNNNNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassette with shutters, unwired
From Get Price