


- Home /
square d breaker
961,107 Results
Refine Results
In Stock
Subcategory
SORT BY

WLL2D330QA
Siemens - Insulated Case
WLL2D330QA, Siemens, WL Series, type , frame size II, drawout, 3P, 3PH, 3000A, 600V, 100kA@480V, UL listed, high interrupting capacity, Draw-Out, complete with solid state ETU725 programmer, LSI - Long-Time, Short-Time and Instantaneous trip functions and 1200A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price

MDN4083LEA0322NMNKNYNHCSX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNKNYNHCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

6403366P1
General Electric - Frame or Mechanism Part
6403366P1 / <strong>412A269P1 / 412A234P1</strong>, General Electric , Trip Shaft Return Spring , Qty 1 required per breaker , suitable for AK-2A/AKU/AKT-50, AK-75/100 air circuit breakers
From Get Price

SKPB36BB2800C
General Electric - Molded Case
SKPB36BB2800C, General Electric, Spectra Series, type , 3P, 3PH, 800A, 600V, 100kA@480V, complete with SRPK1200B800 rating plug, very high interrupting capacity, Bolt-On, suitable for reverse fed applications, UL listed, complete with interchangeable MVT, MicroVersaTrip, Plus trip unit with LSIT - Long-Time, Short-Time, Instantaneous and Targets trip functions, lugs not included, Solid State Electronic, molded case circuit breakers
From Get Price

MDN4083LEA0822NMNANYNHDSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNANYNHDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

B440LSIPR
General Electric - Trip Units And Programmers
B440LSIPR, General Electric, MicroVersaTrip PM, type , replacement trip units and programmers, 4000A current sensor rating, Solid State electronic, LSI - Long-Time, Short-Time and Instantaneous trip functions, protective relays & communications, suitable for use with Power Break II SSD,SHD,SSF,SHF frame insulated case circuit breakers
From Get Price

PB2900T
Westinghouse - Trip Units And Programmers
PB2900T, Westinghouse, PB Series, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 900A, suitable for PB 2500A molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

MDN4083LEA0622NMNJ2ENLDSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNJ2ENLDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

WLH1D312CY
Siemens - Insulated Case
WLH1D312CY, Siemens, WL Series, type , frame size I, drawout, 3P, 3PH, 1200A, 600V, 85kA@480V, UL listed, standard interrupting capacity, Draw-Out, complete with solid state ETU755 programmer + WLGFM76 ground fault module, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and 250A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price

SSD1G134B
General Electric - Insulated Case
SSD1G134B, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, modbus communication & ZSI features and 150A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

SSF4G6J1P
General Electric - Insulated Case
SSF4G6J1P, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, modbus communication & relays features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

LV430693ATS4
Schneider Electric - Molded Case
LV430693ATS4, Schneider Electric, Compact NSX, type , 4P, 3PH, 160A, 690V, 70kA@415V, Bolt-On, complete with NSX160H frame, type UA, 380Vac controller, automatic transfer switch and 4 pole TM80D trip unit, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers
From Get Price

SHB1G3J9N
General Electric - Insulated Case
SHB1G3J9N, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, modbus communication and relays features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

MDN4083LEA0122NMNA2ENYCWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNA2ENYCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

PDG34G0250P4ML
Cutler Hammer - Molded Case
PDG34G0250P4ML, Eaton, Cutler Hammer, Power Defense, type , 3PH, 4P, 600V, 250A, 35kA@480V, Bolt-On, load side lug terminals, complete with PXR25 trip with ARMS LSI - Long-Time, Short-Time and Instantaneous trip functions and Modbus RTU & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price

NEF431070AB
Federal Pacific - Molded Case
NEF431070AB, American, Federal Pacific, NEF Series, type , 3P, 3PH, 70A, 480V, 14kA@480V, standard interrupting capacity, Bolt-On, complete with 1A/1B auxiliary switch, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, and load side lug terminals, Thermal Magnetic, molded case circuit breakers; these breakers are obsolete; however, we still stock them
From Get Price

MDN4083LEA0322NMNJ4YNKMCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNJ4YNKMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0522NMNC2YNKNPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNC2YNKNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0422NMNHNYNADCX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNHNYNADCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

S13ED62AA
Siemens - Shunt Trip
S13ED62AA, Siemens, SENTRON, type , shunt trip, 250VDC, 1 shunt trip and 2 auxiliary switches, suitable for use with ED,HED,HHED,CED,EM6B,EMKB frame molded case circuit breakers
From Get Price

PDG34GH400D5ML
Cutler Hammer - Molded Case
PDG34GH400D5ML, Cutler Hammer, Eaton, Power Defense, type , 3PH, 4P, 600V, 400A, High Override, 35kA@480V, Bolt-On, load side lug terminals, complete with PXR20D trip with ARMS LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and Modbus RTU & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price

PDG32M0175VFAN
Eaton - Molded Case
PDG32M0175VFAN, Eaton, Cutler Hammer, Power Defense, type , 1PH, 2P, 600V, 175A, 65kA@480V, Bolt-On, lug terminals not included, complete with LI - Long-Time and Instantaneous trip functions, 50ºC Thermal Magnetic, molded case circuit breakers; CSA, IEC, UL, CCC certifications; non-UL listed
From Get Price

MDN4083LEA0522NMNX2NNKDAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNX2NNKDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

SHD3G689M
General Electric - Insulated Case
SHD3G689M, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT, modbus communication, relays & ZSI features and 750A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price