


- Home /
15 amp breaker
916,382 Results
Refine Results
In Stock
Subcategory
SORT BY

MDN4083LEA0522NMNE2YHNMSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNE2YHNMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

SHB4G6M3U
General Electric - Insulated Case
SHB4G6M3U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering, RELT, modbus communcation & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

G101NC16
General Electric - Molded Case
G101NC16, General Electric, Redline, Series, 674879, 1P+N, 1PH, 16A, 415V, 10kA@415V, Bolt-On, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case miniature circuit breakers
From Get Price

WLS1D320LQ
Siemens - Insulated Case
WLS1D320LQ, Siemens, WL Series, type , frame size I, drawout, 3P, 3PH, 2000A, 600V, 65kA@480V, UL listed, standard interrupting capacity, Draw-Out, complete with solid state ETU748 programmer+ WLLCD48 LCD display + WLGFM48 ground fault module, LSG - Long-Time, Short-Time and Ground Fault trip functions and 630A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price

SEHF362500LIGES9F8
Schneider Electric - Insulated Case
SEHF362500LIGES9F8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 2500A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & 24VDC shunt trip along with 2 N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

JGS425033GVH08
Cutler Hammer - Molded Case
JGS425033GVH08, Cutler Hammer, Series G, type , 4P, 3PH, 250A, 600V, 35kA@480V, high interrupting capacity, for Marine applications 50°C, not UL listed, Feed-Thru, complete breaker with 310+ electronic, non-interchangeable trip unit and line & load side lug terminals, Solid State, molded case circuit breakers
From Get Price

SGLC3604L4P8
General Electric - Molded Case
SGLC3604L4P8 General Electric Spectra Series, type , 3P, 3PH, 400A, 600V, 65kA@480V, high interrupting capacity, UL listed, suitable for reverse fed applications, complete with microEntelliGuard trip unit with LSIG, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault and ZSI, zone selective interlocking & RELT, reduced energy let-through trip functions and advanced metering, modbus, waveform capture & protective relays communication features, Solid State electronic, molded case circuit breakers
From Get Price

MDN4083LEA0122NMNN2ENCCAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNN2ENCCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

WLL3D350ZL
Siemens - Insulated Case
WLL3D350ZL, Siemens, WL Series, type , frame size III, drawout, 3P, 3PH, 5000A, 600V, 100kA@480V, UL listed, high interrupting capacity, Draw-Out, complete with solid state ETU748 programmer + WLGFA48 ground fault module, LSGA - Long-Time, Short-Time and Ground Fault Alarm trip functions and 4000A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price

K804LIGZ1R
General Electric - Trip Units And Programmers
K804LIGZ1R, General Electric, MicroVersaTrip, replacement trip units and programmers, 400A current sensor rating, Solid State electronic, LIG - Long-Time, Instantaneous and Ground Fault trip functions, ground fault zone-selective interlock, suitable for use with 800A frame WavePro WPS,WPH,WPF,WPX low voltage power circuit breakers
From Get Price

HJL36030M71AABCSRYP
Square D - Molded Case
HJL36030M71AABCSRYP, Square D, PowerPact, type , 3P, 3PH, 30A, 600V, 65kA@480V, UL listed, current limiting, Feed-Thru, suitable for reverse fed applications, I - Instantaneous protection only and line & load side lug terminals, MCP, motor circuit protector, magnetic range 9-325A, Magnetic Only, complete with 1A/1B aux switch, alarm switch, 125 VDC shunt trip, "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $1,927.17

MDN4083LEA0422NMNK4YNKCCX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNK4YNKCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0522NMNJ2YNNCCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNJ2YNNCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0322NMNRNECNNPX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNRNECNNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

LGP46000S40X
Square D - Molded Case
LGP46000S40X, Square D, Schneider Electric, PowerPact, type , 4P, 3PH, 400A, 600V, 35kA@480V, standard interrupting capacity, Bolt-On, UL listed, NA - No Overcurrent Protection, load side lug terminals, Non-Automatic switch, molded case circuit breakers
From Get Price

HDA260504AEBKSP
Square D - Molded Case
HDA260504AEBKSP, Square D, PowerPact, type , 1PH, 2P, B & C phase connection, 50A, 600V, 18kA@480V, standard interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with 1A/1B low-level aux switch, alarm switch and overcurrent trip switch, low-level, 48 VDC shunt trip, molded case circuit breakers
From $1,629.93

WLH1D312AC
Siemens - Insulated Case
WLH1D312AC, Siemens, WL Series, type , frame size I, drawout, 3P, 3PH, 1200A, 600V, 85kA@480V, UL listed, standard interrupting capacity, Draw-Out, complete with solid state ETU745 programmer, LSI - Long-Time, Short-Time and Instantaneous trip functions and 200A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price

HJL36150M74ABBKSK
Square D - Molded Case
HJL36150M74ABBKSK, Square D, PowerPact, type , 3P, 3PH, 150A, 600V, 65kA@480V, UL listed, current limiting, Feed-Thru, suitable for reverse fed applications, I - Instantaneous protection only and line & load side lug terminals, MCP, motor circuit protector, magnetic range 348-1690A, Magnetic Only, complete with 2A/2B aux switch, alarm switch and overcurrent trip switch, low-level, 24 VAC shunt trip, molded case circuit breakers
From $2,179.49

SED362500LIGES6A8
Schneider Electric - Insulated Case
SED362500LIGES6A8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 2500A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 48VDC shunt trip along with 4A4B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

HJA36070BKUA
Square D - Molded Case
HJA36070BKUA, Square D, PowerPact, type , 3PH, 3P, ABC phase connection, 70A, 600V, 65kA@480V, current limiting, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with alarm switch and overcurrent trip switch, low-level, 120 VAC under voltage release (UVR), molded case circuit breakers
From $1,593.69

MDN4083LEA0722NMNA4NNKDWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNA4NNKDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

SHB1G2Q8H
General Electric - Insulated Case
SHB1G2Q8H, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication & ZSI features and 400A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

SEHD361400LSGES9D8
Square D - Insulated Case
SEHD361400LSGES9D8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1400A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & 24VDC shunt trip along with 4A4B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

SEHF36350LSIGES2D4
Schneider Electric - Insulated Case
SEHF36350LSIGES2D4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 350A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 24VDC spring charging motor, shunt closing coil & shunt trip along with 2A2B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price