SEHD362000ES4E8
Square D - Insulated Case
SEHD362000ES4E8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 2000A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MDN4083LEA0522NMNF2YNYMWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNF2YNYMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

NNG3B100
Siemens - Molded Case
NNG3B100 Siemens VL Series, type , 3P, 3PH, 1000A, 600V, 35kA@480V, standard interrupting capacity, 40ºC, Bolt-On, lugs not included, Thermal Magnetic molded case circuit breakers
From Get Price

HGL26150AEBCUOYP
Square D - Molded Case
HGL26150AEBCUOYP, Square D, PowerPact, type , 2P, 1PH, 150A, 600V, 35kA@480V, high interrupting capacity, Feed-Thru, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, complete with 1A/1B low-level aux switch, alarm switch, 24 VDC under voltage release (UVR), "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $2,475.06

SSF4G629R
General Electric - Insulated Case
SSF4G629R, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, RELT, modbus communcation & ZSI features and 1200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

PLL34100U64AE1AB
Schneider Electric - Molded Case
PLL34100U64AE1AB, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 1000A, 480V, 100kA@480V, UL listed, very high interrupting capacity, Feed-Thru, complete with 2A/2B auxiliary switch, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and line & load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price

PGL36060CU44AAB
Schneider Electric - Molded Case
PGL36060CU44AAB, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 600A, 600V, 35kA@480V, UL listed, standard interrupting capacity, Feed-Thru, 100% rated, complete with 2A/2B auxiliary switch, micrologic interchangeable ammeter 6.0A trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and line & load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price

SEHD36600ES5C8
Square D - Insulated Case
SEHD36600ES5C8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 600A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 24VDC shunt trip along with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MDN4083LEA0722NMNH2NNADAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNH2NNADAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

MDN4083LEA0522NMNFNNMNMWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNFNNMNMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed metal padlockable pushbutton cover, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

HE2H030
Siemens - Molded Case
HE2H030, Siemens, ITE, HE Series, type , 2P, 1PH, 30A, 480V, 25kA@480V, high interrupting capacity, Bolt-On, complete with I - Instantaneous protection only and load side lug terminals, high magnetic range, MCP, motor circuit protectors, Magnetic Only, molded case circuit breakers
From Get Price

MDN4083LEA0522NMNA2YNAMSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNA2YNAMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

HMCP400L5S34
Westinghouse - Molded Case
HMCP400L5S34, Eaton, Cutler Hammer, Westinghouse, Series C, type , K Frame, 3P, 3PH, 400A, 600V, 35kA@480V, Feed-Thru, complete with right-pole mounted 380-440Vac or 220-250Vdc rear shunt trip, I - Instantaneous Protection Only and standard line & load side lug terminals, magnetic range 1125-2250A, Magnetic Only, molded case circuit breakers
From Get Price

MDN4083LEA0422NMNC4YNRNSX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNC4YNRNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

PDG34N0250E2NJ
Cutler Hammer - Molded Case
PDG34N0250E2NJ, Eaton, Cutler Hammer, Power Defense, type , 3PH, 4P, 600V, 250A, 100kA@480V, Feed-Thru, line & load side lug terminals, complete with PXR20 trip with LSI - Long-Time, Short-Time and Instantaneous trip functions , Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price

SHF1G2Z8H
General Electric - Insulated Case
SHF1G2Z8H, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering & ZSI features and 400A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

SSD1G2J6E
General Electric - Insulated Case
SSD1G2J6E, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, full metering, modbus communication & relays features and 250A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

SEHF36200LSGES3E5
Schneider Electric - Insulated Case
SEHF36200LSGES3E5, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 200A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip along with AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

PJL36040CU31ARD10
Square D - Molded Case
PJL36040CU31ARD10, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 400A, 600V, 65kA@480V, UL listed, high interrupting capacity, Feed-Thru, 100% rated, complete with direct mounted standard black handle, micrologic interchangeable standard 3.0 trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price

PJP36120CU41B
Schneider Electric - Molded Case
PJP36120CU41B, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 1200A, 600V, 65kA@480V, UL listed, high interrupting capacity, Bolt-On, 100% rated, complete with micrologic interchangeable ammeter 3.0A trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price

SSD4G6L6P
General Electric - Insulated Case
SSD4G6L6P, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering, RELT & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

PKA36040U44AE1BD
Square D - Molded Case
PKA36040U44AE1BD, Schneider Electric, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 400A, 600V, 50kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, complete with 1A/1B overcurrent trip switch, modbus communications, micrologic interchangeable ammeter 6.0A trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breakers
From Get Price

TED134C5020
General Electric - Molded Case
TED134C5020, General Electric, E150 Line, type , 3P, 3PH, 20A, 480V, 18kA@480V, complete with load side lug terminals, standard interrupting capacity, 50°C, Bolt-On, Thermal Magnetic, molded case circuit breakers
From Get Price

MDN4083LEA0422NMNF4ECNNPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNF4ECNNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & 4A/4B auxiliary switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired