


- Home /
breaker
962,938 Results
Refine Results
In Stock
Subcategory
SORT BY

MDN4083LEA0222NMNE4NNKNSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNE4NNKNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

HDL36060U31XAEBHSLYP
Square D - Molded Case
HDL36060U31XAEBHSLYP, Square D, PowerPact, type , 3P, 3PH, 60A, 600V, 18kA@480V, standard interrupting capacity, Feed-Thru, UL listed, suitable for reverse fed applications, can be used for 2P applications, micrologic standard non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Solid State electronic, complete with 1A/1B low-level aux switch, alarm switch low-level, 48 VAC shunt trip, "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $2,354.50

MDN4083LEA0522NMNJ2YNRMSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNJ2YNRMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0522NMNN4YNCCSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNN4YNCCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0222NMNENNNLMPX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNENNNLMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0422NMNHNNNKDSX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNHNNNKDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0522NMNX4YNANCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNX4YNANCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0122NMNKNNNNCPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNKNNNNCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassette, without shutters, pre-wired
From Get Price

MDN4083LEA0122NMNNNENKCSX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNNNENKCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, latch check switch for external wiring, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, upper terminal voltage connection, kirk keylock, Solid State, low voltage power insulated case circuit breakers, shipped as drawout ACB in narrow cassette, shutters and unwired
From Get Price

MDN4083LEA0222NMNK4YNRMWX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNK4YNRMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0222NMNE2NNRMSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNE2NNRMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0422NMNA2NNCNWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNA2NNCNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0322NMNC4YNKNWX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNC4YNKNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0722NMNGNNNHNWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNGNNNHNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0422NMNC4ENHNSX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNC4ENHNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0722NMNE4NNCNSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNE4NNCNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0822NMNRNYNLDAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNRNYNLDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

MDN4083LEA0522NMNA2NNNCCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNA2NNNCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0422NMNFNYNRNWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNFNYNRNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0122NMNHNNNCCSX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNHNNNCCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0422NMNCNNNCCSX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNCNNNCCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

HLA36150U31XAFBCSDYP
Square D - Molded Case
HLA36150U31XAFBCSDYP, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 150A, 600V, 100kA@480V, current limiting, I-Line Style Plug-In, UL listed, suitable for reverse connection, can be used for 2P applications, micrologic standard 3.2 non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Solid State electronic, complete with 2A/2B low-level aux switch, alarm switch, 208/277 VAC shunt trip, "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $3,937.50

MDN4083LEA0322NMNANYNYMCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNANYNYMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0522NMNFNYNHNPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNFNYNHNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price