


- Home /
breaker
962,938 Results
Refine Results
In Stock
Subcategory
SORT BY

MDN4083LEA0522NMNA2NNYMPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNA2NNYMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0722NMNR4YNANPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNR4YNANPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

HDA36100U44XAEBKSJYP
Square D - Molded Case
HDA36100U44XAEBKSJYP, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 100A, 600V, 18kA@480V, standard interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse connection, micrologic ammeter 6.2A non-interchangeable trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, complete with 1A/1B low-level aux switch, alarm switch and overcurrent trip switch, low-level, 525/600 VAC shunt trip, "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $2,340.71

MDN4083LEA0122NMNC4ENHDWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNC4ENHDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0522NMNJ2NNRCCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNJ2NNRCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0722NMNCNYNCDPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNCNYNCDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0422NMNX2YNCNPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNX2YNCNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

HDA36060U44XAEBKUNYP
Square D - Molded Case
HDA36060U44XAEBKUNYP, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 60A, 600V, 18kA@480V, standard interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse connection, micrologic ammeter 6.2A non-interchangeable trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, complete with 1A/1B low-level aux switch, alarm switch and overcurrent trip switch, low-level, 12 VDC under voltage release (UVR), "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $2,650.62

MDN4083LEA0722NMNE4ENKDSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNE4ENKDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0422NMNR2YNKMWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNR2YNKMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0822NMNN2NNRCPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNN2NNRCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

HJA36060U44XAEBKUHYP
Square D - Molded Case
HJA36060U44XAEBKUHYP, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 60A, 600V, 65kA@480V, current limiting, I-Line Style Plug-In, UL listed, suitable for reverse connection, micrologic ammeter 6.2A non-interchangeable trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, complete with 1A/1B low-level aux switch, alarm switch and overcurrent trip switch, low-level, 380/480 VAC under voltage release (UVR), "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $3,795.12

HRA36100U31XAEBEUNYP
Square D - Molded Case
HRA36100U31XAEBEUNYP, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 100A, 600V, 200kA@480V, current limiting, I-Line Style Plug-In, UL listed, suitable for reverse connection, can be used for 2P applications, micrologic standard 3.2 non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Solid State electronic, complete with 1A/1B low-level aux switch, alarm switch and overcurrent trip switch, 12 VDC under voltage release (UVR), "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $4,147.50

MDN4083LEA0422NMNX2ENKDSX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNX2ENKDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0522NMNRNYNRCPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNRNYNRCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0522NMNCNYNRDPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNCNYNRDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0322NMNA4YNRMWX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNA4YNRMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0422NMNCNYNCDPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNCNYNCDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0622NMNXNENYCPX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNXNENYCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0822NMNKNNNYCPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNKNNNYCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0622NMNC4NNHNWX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNC4NNHNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

HDA36100U43XAEBKUNYP
Square D - Molded Case
HDA36100U43XAEBKUNYP, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 100A, 600V, 18kA@480V, standard interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse connection, micrologic ammeter 5.2A non-interchangeable trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, complete with 1A/1B low-level aux switch, alarm switch and overcurrent trip switch, low-level, 12 VDC under voltage release (UVR), "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $2,205.00

MDN4083LEA0822NMNE4NNHMSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNE4NNHMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0122NMNK4NNHNWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNK4NNHNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price