


- Home /
breaker
962,938 Results
Refine Results
In Stock
Subcategory
SORT BY

MDN4083LEA0122NMNK4ECNNCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNK4ECNNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & 4A/4B auxiliary switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0822NMNF4YNLNCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNF4YNLNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0322NMNE4NNHNPX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNE4NNHNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0722NMNK4EHNNCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNK4EHNNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & 4A/4B auxiliary switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

HGA36060U33XAFBCUDYP
Square D - Molded Case
HGA36060U33XAFBCUDYP, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 60A, 600V, 35kA@480V, high interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse connection, can be used for 2P applications, micrologic standard 3.2S non-interchangeable trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, complete with 2A/2B low-level aux switch, alarm switch, 208/277 VAC under voltage release (UVR), "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $2,126.25

MDN4083LEA0722NMNF2NNLNCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNF2NNLNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0722NMNN4ECNMWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNN4ECNMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0422NMNG4YNHNPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNG4YNHNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, operations counter, Ronis key interlock, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0322NMNJNYNKCCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNJNYNKCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0622NMNK4ENHCSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNK4ENHCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0122NMNJ2ENKCPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNJ2ENKCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0722NMNC4NNKCWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNC4NNKCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0122NMNC2NNCCCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNC2NNCCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0122NMNENYNNCWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNENYNNCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0122NMNF4NNNCPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNF4NNNCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0822NMNC4ENLCCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNC4ENLCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0222NMNR2NNCDSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNR2NNCDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0822NMNC2YNHNCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNC2YNHNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0222NMNE4ENKCCX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNE4ENKCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0422NMNN4NNKDCX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNN4NNKDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0822NMNC4ECNNPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNC4ECNNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0722NMNJ4YNNDCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNJ4YNNDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

HDL36060U44XAFBHURYP
Square D - Molded Case
HDL36060U44XAFBHURYP, Square D, PowerPact, type , 3P, 3PH, 60A, 600V, 18kA@480V, standard interrupting capacity, Feed-Thru, UL listed, suitable for reverse fed applications, micrologic ammeter non-interchangeable trip with LSIG, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and line & load side lug terminals, Solid State electronic, complete with 2A/2B low-level aux switch, alarm switch low-level, 125 VDC under voltage release (UVR), "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $2,520.82

MDN4083LEA0622NMNX4YNAMPX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNX4YNAMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price