Limited Stock
SSD4G668N
SSD4G668N
General Electric - Insulated Case
SSD4G668N, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communcation & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHB1G3C3F
SHB1G3C3F
General Electric - Insulated Case
SHB1G3C3F, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering & modbus communication features and 300A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHD1G2W8D
SHD1G2W8D
General Electric - Insulated Case
SHD1G2W8D, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication, relays & ZSI features and 225A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHD5G8L4U
SHD5G8L4U
General Electric - Insulated Case
SHD5G8L4U, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 150kA@480V, high interrupting capacity, Draw-Out, 3000A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, RELT & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHD1G3A4F
SHD1G3A4F
General Electric - Insulated Case
SHD1G3A4F, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering & RELT features and 300A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHF4G6Z3U
SHF4G6Z3U
General Electric - Insulated Case
SHF4G6Z3U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHF5G8C92
SHF5G8C92
General Electric - Insulated Case
SHF5G8C92, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, front connected, 3000A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering & modbus communication features and 3000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHF4G6Y8M
SHF4G6Y8M
General Electric - Insulated Case
SHF4G6Y8M, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communcation, relays & ZSI features and 750A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHF4G6Q8U
SHF4G6Q8U
General Electric - Insulated Case
SHF4G6Q8U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communcation & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSB2G491N
SSB2G491N
General Electric - Insulated Case
SSB2G491N, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 1600A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, modbus communication, relays & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD3G6F3W
SSD3G6F3W
General Electric - Insulated Case
SSD3G6F3W, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering & modbus communication features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHF3G6J2W
SHF3G6J2W
General Electric - Insulated Case
SHF3G6J2W, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 2000A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering, modbus communication & relays features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD3G6N6M
SSD3G6N6M
General Electric - Insulated Case
SSD3G6N6M, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering, modbus communication & ZSI features and 750A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHF1G1K3B
SHF1G1K3B
General Electric - Insulated Case
SHF1G1K3B, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering & ZSI features and 150A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD1G122C
SSD1G122C
General Electric - Insulated Case
SSD1G122C, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, current metering, RELT, modbus communication & ZSI features and 200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD2G4X4H
SSD2G4X4H
General Electric - Insulated Case
SSD2G4X4H, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 1600A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering features and 400A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHD3G6Q8N
SHD3G6Q8N
General Electric - Insulated Case
SHD3G6Q8N, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSB2G521U
SSB2G521U
General Electric - Insulated Case
SSB2G521U, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 1600A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, current metering, RELT, modbus communication & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSB1G216J
SSB1G216J
General Electric - Insulated Case
SSB1G216J, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering, RELT & ZSI features and 500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSF3G622N
SSF3G622N
General Electric - Insulated Case
SSF3G622N, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 2000A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, current metering, RELT, modbus communication & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD4G6L4R
SSD4G6L4R
General Electric - Insulated Case
SSD4G6L4R, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, RELT & ZSI features and 1200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHF2G4B9N
SHF2G4B9N
General Electric - Insulated Case
SHF2G4B9N, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 1600A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, RELT & modbus communication features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD6G9Y21
SSD6G9Y21
General Electric - Insulated Case
SSD6G9Y21, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 100kA@480V, standard interrupting capacity, Draw-Out, 3000A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering, modbus communication, relays & ZSI features and 2500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHF2G551Q
SHF2G551Q
General Electric - Insulated Case
SHF2G551Q, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 1600A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, RELT, modbus communication & ZSI features and 1100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems