MDN4083LEA0122NMNX2ENKMCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNX2ENKMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

WLL2F330UE
Siemens - Insulated Case
WLL2F330UE, Siemens, WL Series, type , frame size II, fixed mount, 3P, 3PH, 3000A, 600V, 100kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with solid state ETU745 programmer + WLGFA48, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions and 2000A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price

SSD4G6N3M
General Electric - Insulated Case
SSD4G6N3M, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering, modbus communcation & ZSI features and 750A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

MDN4083LEA0822NMNFNENRNPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNFNENRNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

B204LSIGPMR
General Electric - Trip Units And Programmers
B204LSIGPMR, General Electric, MicroVersaTrip PM, type , replacement trip units and programmers, 400A current sensor rating, Solid State electronic, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, protective relays, metering & communications, suitable for use with Power Break II SSD,SHD,SSF,SHF frame insulated case circuit breakers
From Get Price

MDN4083LEA0422NMNH2ENKNSX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNH2ENKNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0222NMNK4YNYNPX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNK4YNYNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0122CPR44ENNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122CPR44ENNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, factory installed 24Vdc shunt trip (ST), 48Vdc second shunt trip (STA) & 4A/4B auxiliary switch, electrically operated with factory installed 220-240Vac motor operator & 208-250Vac spring release device (SRD), Solid State, low voltage power insulated case circuit breakers
From Get Price

HLK3E400L
Siemens - Molded Case
HLK3E400L, Siemens, VL Series, type , 3P, 3PH, 400A, 600V, 65kA@480V, high interrupting capacity, Feed-Thru, complete with non-interchangeable electronic LCD trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, line & load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price

MN4R1W04
General Electric - Insulated Case
MN4R1W04, General Electric, M-PACT Plus, type , frame size 1, manually operated, with cassette and 5 N.O.-3 N.C. Auxiliary switch, 4P, 3PH, right side neutral, 400A, 690V, 65kA@415V, Draw-Out, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers
From Get Price

PDG42M0800VFAL
Eaton - Molded Case
PDG42M0800VFAL, Eaton, Cutler Hammer, Power Defense, type , 50º C non-UL listed, 1PH, 2P, 600V, 800A, 65kA@480V, Bolt-On, load side lug terminals, complete with LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers; globally rated non-UL listed
From Get Price

MDN4083LEA0622NMNK2YNCDCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNK2YNCDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0522NMNF2NNHNSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNF2NNHNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

PDG24K0060P3DN
Eaton - Molded Case
PDG24K0060P3DN, Eaton, Cutler Hammer, Power Defense, type , 3PH, 4P, 600V, 60A, 50kA@480V, Bolt-On, no lug terminals, complete with Xpert Release PXR25 trip with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, relays, modbus and CAM, Solid State electronic, molded case circuit breakers; globally rated
From Get Price

TKMAAS2AB2LB
General Electric - Auxiliary
TKMAAS2AB2LB, General Electric, K1200 Line, type , auxiliary, 1 auxiliary switch kit, left pole mounted, lead exit from back of breaker, 2A/2B, rated for 240VAC, suitable for use with TKC,TKM,THKM,TB6,TBC6,TB8,TBC8 frame molded case circuit breakers
From Get Price

PDG23M0100E2MK
Eaton - Molded Case
PDG23M0100E2MK, Cutler Hammer, Eaton, Power Defense, type , 3PH, 3P, 600V, 100A, 65kA@480V, Bolt-On, line side lug terminals, complete with Xpert Release PXR20 trip with LSI - Long-Time, Short-Time and Instantaneous trip functions, relays and modbus, Solid State electronic, molded case circuit breakers; globally rated
From Get Price

MDN4083LEA0222NMNG2YNYNAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNG2YNYNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch, Kirk key interlock & operations counter, Solid State, low voltage power insulated case circuit breakers
From Get Price

MDN4083LEA0722NMNJ2YNCCPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNJ2YNCCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0822NMNC2ENHMSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNC2ENHMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0222NMNN4YCNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNN4YCNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price

SSD2G5K9Q
General Electric - Insulated Case
SSD2G5K9Q, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 1600A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering & ZSI features and 1100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

MDN4083LEA0622NMNX4ENYDSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNX4ENYDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

SHF2G566R
General Electric - Insulated Case
SHF2G566R, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 1600A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, full metering, modbus communication & ZSI features and 1200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

MDN4083LEA0422NMNGNNNADAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNGNNNADAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price