1. Home / 
  2. breaker

SORT BY
In Stock
HDL36060U31XAFBKUSYP
HDL36060U31XAFBKUSYP
Square D - Molded Case
HDL36060U31XAFBKUSYP, Square D, PowerPact, type , 3P, 3PH, 60A, 600V, 18kA@480V, standard interrupting capacity, Feed-Thru, UL listed, suitable for reverse fed applications, can be used for 2P applications, micrologic standard non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Solid State electronic, complete with 2A/2B low-level aux switch, alarm switch and overcurrent trip switch, low-level, 250 VDC under voltage release (UVR), "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $1,783.68
Limited Stock
MDN4083LEA0522NMNC4NNLCWX
MDN4083LEA0522NMNC4NNLCWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNC4NNLCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0522NMNK4YNRCPX
MDN4083LEA0522NMNK4YNRCPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNK4YNRCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNR2YNADWX
MDN4083LEA0722NMNR2YNADWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNR2YNADWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0622NMNK2YNRCWX
MDN4083LEA0622NMNK2YNRCWX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNK2YNRCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
In Stock
HGA36100U31XAEBKUSYP
HGA36100U31XAEBKUSYP
Square D - Molded Case
HGA36100U31XAEBKUSYP, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 100A, 600V, 35kA@480V, high interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse connection, can be used for 2P applications, micrologic standard 3.2 non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Solid State electronic, complete with 1A/1B low-level aux switch, alarm switch and overcurrent trip switch, low-level, 250 VDC under voltage release (UVR), "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $2,270.10
Limited Stock
MDN4083LEA0822NMNH4YNKDPX
MDN4083LEA0822NMNH4YNKDPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNH4YNKDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0222NMNF2YNRDSX
MDN4083LEA0222NMNF2YNRDSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNF2YNRDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0522NMNK2YNRDPX
MDN4083LEA0522NMNK2YNRDPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNK2YNRDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0122NMNHNYNYCWX
MDN4083LEA0122NMNHNYNYCWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNHNYNYCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0222NMNH4NNYDPX
MDN4083LEA0222NMNH4NNYDPX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNH4NNYDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0522NMNF2NNHDCX
MDN4083LEA0522NMNF2NNHDCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNF2NNHDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0222NMNJ2YNKCWX
MDN4083LEA0222NMNJ2YNKCWX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNJ2YNKCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0422NMNC4NNYDWX
MDN4083LEA0422NMNC4NNYDWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNC4NNYDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0622NMNC4YNKCPX
MDN4083LEA0622NMNC4YNKCPX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNC4YNKCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0522NMNG2NNHDWX
MDN4083LEA0522NMNG2NNHDWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNG2NNHDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNXNYMNDCX
MDN4083LEA0722NMNXNYMNDCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNXNYMNDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed metal padlockable pushbutton cover, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0722NMNA2NNACPX
MDN4083LEA0722NMNA2NNACPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNA2NNACPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNK4NNLDSX
MDN4083LEA0722NMNK4NNLDSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNK4NNLDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0422NMNN4NNLDPX
MDN4083LEA0422NMNN4NNLDPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNN4NNLDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0522NMNJ2YHNMCX
MDN4083LEA0522NMNJ2YHNMCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNJ2YHNMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0522NMNF4ENHDWX
MDN4083LEA0522NMNF4ENHDWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNF4ENHDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0322NMNN2YNHCCX
MDN4083LEA0322NMNN2YNHCCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNN2YNHCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0122NMNJ4YNCCCX
MDN4083LEA0122NMNJ4YNCCCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNJ4YNCCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price