


- Home /
breaker
962,938 Results
Refine Results
In Stock
Subcategory
SORT BY

MDN4083LEA0422NMNK4NHNMSX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNK4NHNMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0722NMNCNECNCCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNCNECNCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0622NMNK4YNCCPX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNK4YNCCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0622NMNX2YNKCSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNX2YNKCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0822NMNRNECNCCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNRNECNCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0222NMNK4YCNDAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNK4YCNDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

MDN4083LEA0222NMNH2YNACWX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNH2YNACWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0822NMNXNNMNCPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNXNNMNCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed metal padlockable pushbutton cover, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0222NMNH4NNYCSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNH4NNYCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0822NMNE4YNRDPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNE4YNRDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0722NMNJ4YNYCCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNJ4YNYCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0322NMNFNNMNDSX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNFNNMNDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed metal padlockable pushbutton cover, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0822NMNJ4YHNMCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNJ4YHNMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0322NMNE2NNADWX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNE2NNADWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0322NMNENYNLDCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNENYNLDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0222NMNANYNYDCX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNANYNYDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0222NMNA4NNHDPX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNA4NNHDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0822NMNF4YNCDSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNF4YNCDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0722NMNX4YNRDCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNX4YNRDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0122ANAX2YNNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122ANAX2YNNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long Time and Instantaneous trip functions, load side lug terminals, factory installed 110-127Vac shunt trip (ST), 380-415Vac UVR, 2A/2B auxiliary switch, mechanical trip indicator & OTS switch, electrically operated with factory installed 110-120Vac motor operator & spring release device (SRD), Solid State, low voltage power insulated case circuit breakers
From Get Price

MDN4083LEA0222NMNA2NNCDWX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNA2NNCDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0122RPRG2NNNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122RPRG2NNNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, factory installed 208-250Vdc shunt trip (ST), 32Vdc UVR, 2A/2B auxiliary switch & mechanical trip indicator, electrically operated with factory installed 220-240Vac motor operator & 208-250Vac spring release device (SRD), Solid State, low voltage power insulated case circuit breakers
From Get Price

MDN4083LEA0422NMNF2YNRDWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNF2YNRDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0622NMNA4NNADPX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNA4NNADPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price