1. Home / 
  2. square d breaker

SORT BY
Limited Stock
E4H-A36-4P-1600A-BO-EO-LSI
E4H-A36-4P-1600A-BO-EO-LSI
ABB - Insulated Case
E4H-A36-4P-1600A-BO-EO-LSI, ABB, EMax, type , 4P, 3PH, 3600A frame, 1600A rating plug, 600V, 85kA@480V, fixed/Bolt-On, electrically operated, Solid State electronic with LSI - Long-Time, Short-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
MDN4083LEA0222NMNH4YNHNSX
MDN4083LEA0222NMNH4YNHNSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNH4YNHNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0222NMNNNENRMWX
MDN4083LEA0222NMNNNENRMWX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNNNENRMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Ronis keylock, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassette, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0322NMNANYNYMWX
MDN4083LEA0322NMNANYNYMWX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNANYNYMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0122NMNR2NNHCCX
MDN4083LEA0122NMNR2NNHCCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNR2NNHCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0822NMNH2ENRMPX
MDN4083LEA0822NMNH2ENRMPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNH2ENRMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
LV431403X52E160
LV431403X52E160
Schneider Electric - Molded Case
LV431403X52E160, Schneider Electric, Compact NSX, type , 3P, 3PH, 250A, 690V, 36kA@415V, Bolt-On, complete with NSX250F frame and 3 pole, 160A Micrologic 5.2E trip unit with LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
0163.0200
0163.0200
Sca Schucker - Tools
0163.0200, Sca Schucker tools
From Get Price
Limited Stock
MDN4083LEA0822NMNHNNCNNAX
MDN4083LEA0822NMNHNNCNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNHNNCNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SHD2G558U
SHD2G558U
General Electric - Insulated Case
SHD2G558U, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 1600A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
PDG33NH250E5XK
PDG33NH250E5XK
Cutler Hammer - Molded Case
PDG33NH250E5XK, Cutler Hammer, Eaton, Power Defense, type , 3PH, 3P, 600V, 250A, High Override, 100kA@480V, Bolt-On, line side lug terminals, complete with PXR20 trip with ARMS LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions with CAM link, ZSI & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
SHB1G333I
SHB1G333I
General Electric - Insulated Case
SHB1G333I, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering, modbus communication & ZSI features and 450A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0522NMNA2YNKNPX
MDN4083LEA0522NMNA2YNKNPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNA2YNKNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SHD6G9Z61
SHD6G9Z61
General Electric - Insulated Case
SHD6G9Z61, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 150kA@480V, high interrupting capacity, Draw-Out, 3000A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering & ZSI features and 2500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHF1G299D
SHF1G299D
General Electric - Insulated Case
SHF1G299D, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, modbus communication, relays & ZSI features and 225A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
XSUCMFAZZAAAA00000
XSUCMFAZZAAAA00000
ABB - Molded Case
XSUCMFAZZAAAA00000, ABB, SACE Tmax XT, type , 3PH, 3P, 600V, 800A, 50kA@480V, Bolt-On, front terminals, Magnetic Only, MCP, I - Instantaneous protection only; 1SDA103376R1 global reference
From Get Price
Limited Stock
MDN4083LEA0822NMNENEMNNCX
MDN4083LEA0822NMNENEMNNCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNENEMNNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed metal padlockable pushbutton cover, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0722NMNXNYNLCSX
MDN4083LEA0722NMNXNYNLCSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNXNYNLCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch, Castell key interlock & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0722NMNFNNNCDPX
MDN4083LEA0722NMNFNNNCDPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNFNNNCDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
LT363039
LT363039
Cutler Hammer - Trip Units And Programmers
LT363039, Cutler Hammer, Series G, type , interchangeable trip units and programmers with ALSIG - Arcflash Reduction, Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, rated for 630A, suitable for Series G LGE,LGS,LGH,LGC,LGU,LGX molded case circuit breaker frame types with Arcflash reduction maintenance system, Solid State electronic trip units & circuit breakers
From Get Price
Limited Stock
NZMH2-S160-SVE
NZMH2-S160-SVE
Klockner Moeller - Molded Case
NZMH2-S160-SVE, Eaton, Klockner Moeller, NZM2 Series, type , 3P, 3PH, 690V, 160A, 150kA@415V, high switching capacity, Plug-In unit, Thermal Magnetic, molded case circuit breakers, IEC rated/UL listed
From Get Price
Limited Stock
SSD2G5Z4P
SSD2G5Z4P
General Electric - Insulated Case
SSD2G5Z4P, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 1600A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering & ZSI features and 1000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
PDG62N2500E2WM
PDG62N2500E2WM
Cutler Hammer - Molded Case
PDG62N2500E2WM, Cutler Hammer, Eaton, Power Defense, type , 1PH, 2P, 600V, 2500A, 85kA@480V, Bolt-On, no terminals with metric tapped conductors, complete with PXR20 trip with LSI - Long-Time, Short-Time and Instantaneous trip functions with relays, modbus & ZSI option, Solid State electronic, molded case circuit breakers; globally rated
From Get Price
Limited Stock
RLI-800A-MO-DO-LSG
RLI-800A-MO-DO-LSG
Siemens-Allis - Air
RLI-800A-MO-DO-LSG, Siemens-Allis, RL Series, type , 800A frame size, manually operated/Draw-Out, 3P, 3PH, 150-800A current sensor rating, 600V, 100kA@480V, originally supplied with StaticTrip III RMS trip device but can also be retrofitted with a modern Solid State electronic trip unit with LSG - Long-Time, Short-Time and Ground Fault trip functions, low voltage power air circuit breakers
From Get Price