- Home /
15 amp breaker
97,864 Results
Refine Results
In Stock
Subcategory
SORT BY

XT2HQ3070MFF000XXX
ABB - Molded Case
XT2HQ3070MFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 3-Pole, 70A, 600V, 25kA@600V, Motor Circuit Protector (MCP), UL 100% Rated, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No - 1SDA07211R1 global reference
From Get Price

EEHLD560500SB2
Cutler Hammer - Mounting Hardware
EEHLD560500SB2, Cutler Hammer, EE Series, mounting hardware, plug-in mounting module, rated for 500A, BCL or ABR phase connection, 600V max, Copper, Single Branch mounting style, suitable for use with LD,HLD,LDC circuit breaker frames and EP panelboards; these modules are obsolete, however we still stock them
From Get Price

EENDC420900TB2
Cutler Hammer - Mounting Hardware
EENDC420900TB2, Cutler Hammer, EE Series, mounting hardware, plug-in mounting module, rated for 900A, ABL or BCR phase connection, 240V max, Copper, Dual/Twin Branch mounting style, suitable for use with ND,HND,NDC circuit breaker frames and EP panelboards; these modules are obsolete, however we still stock them
From Get Price

XT4XQ4035AFF000XXX
ABB - Molded Case
XT4XQ4035AFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 4-Pole, 35A, 600V, 100kA@600V, Thermal Magnetic Fixed (TMF), UL 100% Rated, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No - 1SDA07211R1 global reference
From Get Price

ECN22A3EAD
Cutler Hammer - Motor Starter
ECN22A3EAD, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP, type , 3P, 3PH, 1 HP @ 200V, 600V, complete with 208V coil, NEMA size 00, 15A HMCP circuit breaker enclosed in NEMA Type 4 painted steel enclosure, suitable for use with Freedom Series motor control systems
From Get Price

XT4XQ3125AFF000XXX
ABB - Molded Case
XT4XQ3125AFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 3-Pole, 125A, 600V, 100kA@600V, Thermal Magnetic Fixed (TMF), UL 100% Rated, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No - 1SDA07211R1 global reference
From Get Price

XT4XQ4110BFF000XXX
ABB - Molded Case
XT4XQ4110BFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 4-Pole, 110A, 600V, 100kA@600V, Thermal magnetic adjustable (TMD/TMA), UL 100% Rated, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No - 1SDA07211R1 global reference
From Get Price

XT4HU3060JFF000XXX
ABB - Molded Case
XT4HU3060JFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 3-Pole, 60A, 600V, 25kA@600V, Ekip I (Electronic, Instantaneous trip only), UL Standard, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No - 1SDA07211R1 global reference
From Get Price

CR492B604MA1AAAAA
General Electric - Motor Starter
CR492B604MA1AAAAA, General Electric, CR492, type , 3P, 3PH, 3-18A, 600V, 1 hp, complete with 460V-480V 60Hz, AC coil, 2 speed, 1 winding, mag-break circuit breaker type magnetic starter, NEMA size 00 includes NEMA type 3R surface mount enclosure, suitable for use with CR492 motor control systems
From Get Price

8539SJG2V03
Square D - Motor Starter
8539SJG2V03, Square D, Class 8539, combination non-reversing motor starter, NEMA size 00, requires 3 thermal units, supplied with 900A MAL thermal magnetic circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 250 HP @ 240V, complete with 240V coil, suitable for use with Class 8539 motor control systems
From Get Price

XT2HQ3040WFF000XXX
ABB - Molded Case
XT2HQ3040WFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 3-Pole, 40A, 600V, 25kA@600V, Ekip M Touch LRIU, UL 100% Rated, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No - 1SDA07211R1 global reference
From Get Price

EEFDC540150SB2
Cutler Hammer - Mounting Hardware
EEFDC540150SB2, Cutler Hammer, EE Series, mounting hardware, plug-in mounting module, rated for 150A, BCL or ABR phase connection, 480V max, Copper, Single Branch mounting style, suitable for use with FDB,FD,HFD,FDC circuit breaker frames and EP panelboards; these modules are obsolete, however we still stock them
From Get Price

EEND461000TB2
Cutler Hammer - Mounting Hardware
EEND461000TB2, Cutler Hammer, EE Series, mounting hardware, plug-in mounting module, rated for 1000A, ABL or BCR phase connection, 600V max, Copper, Dual/Twin Branch mounting style, suitable for use with ND,HND,NDC circuit breaker frames and EP panelboards; these modules are obsolete, however we still stock them
From Get Price

XT4XU3090BFF000XXX
ABB - Molded Case
XT4XU3090BFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 3-Pole, 90A, 600V, 100kA@600V, Thermal magnetic adjustable (TMD/TMA), UL Standard, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No - 1SDA07211R1 global reference
From Get Price

XT1HU4110AFF000XXX
ABB - Molded Case
XT1HU4110AFF000XXX, ABB, SACE Tmax XT, Type , 4-Pole, 110A, 600V, 25kA@600V, Thermal Magnetic Fixed (TMF), UL Standard, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, no key lock, molded case circuit breaker -1SDA074664R1 global reference
From Get Price

CP3T1400
ITE - Trip Units And Programmers
CP3T1400, ITE, Cordon, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 1400A, suitable for 1600A- CP Cordon molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From $2,502.98

CR494F608MQ1AAAAA
General Electric - Motor Starter
CR494F608MQ1AAAAA, General Electric, CR494, type , 3P, 3PH, 125-135A, 600V, 30 hp, complete with 200V-208V 60Hz, AC coil, 2 speed, 2 winding, mag-break circuit breaker type, magnetic starter, NEMA size 00 includes NEMA type 3R surface mount enclosure, suitable for use with CR494 motor control systems
From Get Price

EEJDC320070SB2
Cutler Hammer - Mounting Hardware
EEJDC320070SB2, Cutler Hammer, EE Series, mounting hardware, plug-in mounting module, rated for 70A, ABC phase connection, 240V max, Copper, Single Branch mounting style, suitable for use with ED,EDH,EDC,JD,HJD,JDC circuit breaker frames and EP panelboards; these modules are obsolete, however we still stock them
From Get Price

CR414F205TR1AAAAA
General Electric - Motor Starter
CR414F205TR1AAAAA, General Electric, CR414, type , 3P, 3PH, 135-150A, 600V, 100 hp, complete with 575V-600V 60Hz, AC coil, 2 speed, 2 winding, thermal magnetic circuit breaker type, magnetic starter, NEMA size 00 includes NEMA type 12 surface mount enclosure, suitable for use with CR414 motor control systems
From Get Price

MP16-3P-800A
Merlin Gerin - Insulated Case
MP16-3P-800A, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1600A frame with 1600A trip and 800A rating plug, 3P, 3PH, 600V, 50kA@480V, available with STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U trip units, Solid State electronic, insulated case circuit breakers
From Get Price

XT3NQ3110AFF000XXX
ABB - Molded Case
XT3NQ3110AFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 3-Pole, 110A, 600V, 10kA@600Y/347V, Thermal Magnetic Fixed (TMF), UL 100% Rated, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No - 1SDA07211R1 global reference
From Get Price

EEHMDL520400TB2
Cutler Hammer - Mounting Hardware
EEHMDL520400TB2, Cutler Hammer, EE Series, mounting hardware, plug-in mounting module, rated for 400A, BCL or ABR phase connection, 240V max, Copper, Dual/Twin Branch mounting style, suitable for use with MDL,HMDL circuit breaker frames and EP panelboards; these modules are obsolete, however we still stock them
From Get Price

XT2VU3125DFF000XXX
ABB - Molded Case
XT2VU3125DFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 3-Pole, 125A, 600V, 42kA@600V, Molded Case Switch Disconnector (MCS), UL Standard, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No - 1SDA07211R1 global reference
From Get Price

XT3SU3125MFF000XXX
ABB - Molded Case
XT3SU3125MFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 3-Pole, 125A, 600V, 10kA@600Y/347V, Motor Circuit Protector (MCP), UL Standard, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No - 1SDA07211R1 global reference
From Get Price