MDN4083LEA0622NMNHNENLDSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNHNENLDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

SHB6G9K92
General Electric - Insulated Case
SHB6G9K92, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, back connected, 3000A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering & ZSI features and 3000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

MDN4083LEA0122NMNG2YHNDWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNG2YHNDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0622NMNF2YNCDSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNF2YNCDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

PDG33F0200TFAL
Cutler Hammer - Molded Case
PDG33F0200TFAL, Cutler Hammer, Eaton, Power Defense, type , 3PH, 3P, 600V, 200A, 25kA@480V, Bolt-On, load side lug terminals, complete with LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price

PDG21N0050VFFJ
Eaton - Molded Case
PDG21N0050VFFJ, Cutler Hammer, Eaton, Power Defense, type , 50ºC, 1PH, 1P, 600V, 50A, 85kA@480V, Feed-Thru, complete with LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers; CSA, IEC, CCC certifications; non-UL listed
From Get Price

PDG32PH400P4MN
Cutler Hammer - Molded Case
PDG32PH400P4MN, Eaton, Cutler Hammer, Power Defense, type , 1PH, 2P, 600V, 400A, High Override, 100kA@480V, Bolt-On, no lug terminals, complete with PXR25 trip with ARMS LSI - Long-Time, Short-Time and Instantaneous trip functions and Modbus RTU & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price

DSL206-100A-EO-DO-LIG
Cutler Hammer - Air
DSL206-100A-EO-DO-LIG, Cutler Hammer, DSLII Series, type , 800A frame size, electrically operated/Draw-Out, with current limiters, 3P, 3PH, 100A, 600V, 200kA@600V, available with solid state trip unit, Solid State electronic, air circuit breakers
From Get Price

MDN4083LEA0722NMNC2YNAMWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNC2YNAMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

SSF4G6B1R
General Electric - Insulated Case
SSF4G6B1R, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, current metering, RELT & modbus communication features and 1200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

MDN4083LEA0522NMNJ2NNYMAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNJ2NNYMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price

SHD3G698W
General Electric - Insulated Case
SHD3G698W, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communication, relays & ZSI features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

PDF34F0125P5WJ
Eaton - Molded Case
PDF34F0125P5WJ, Cutler Hammer, Eaton, Power Defense, type , 3PH, 4P, 600V, 125A, 25kA@480V, 100% UL, Feed-Thru, line & load side lug terminals, complete with PXR25 trip with ARMS LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions with Modbus RTU, ZSI & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price

WLS1D316MN
Siemens - Insulated Case
WLS1D316MN, Siemens, WL Series, type , frame size I, drawout, 3P, 3PH, 1600A, 600V, 65kA@480V, UL listed, standard interrupting capacity, Draw-Out, complete with solid state ETU748 programmer + WLLCD48 LCD display + WLGFA48 ground fault module, LSGA - Long-Time, Short-Time and Ground Fault Alarm trip functions and 700A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price

SHD2G487K
General Electric - Insulated Case
SHD2G487K, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 1600A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication, relays & ZSI features and 600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

MDN4083LEA0322NMNE2ENNMWX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNE2ENNMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions & load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

8PCV-05-006
TE Connectivity - Tools
8PCV-05-006, TE Connectivity tools
From Get Price

MDN4083LEA0522NMNH4ENLCAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNH4ENLCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

PDG34N0125E2NK
Cutler Hammer - Molded Case
PDG34N0125E2NK, Cutler Hammer, Eaton, Power Defense, type , 3PH, 4P, 600V, 125A, 100kA@480V, Bolt-On, line side lug terminals, complete with PXR20 trip with LSI - Long-Time, Short-Time and Instantaneous trip functions , Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price

MDN4083LEA0422NMNF2NNYCSX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNF2NNYCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

459A373P3
General Electric - Frame or Mechanism Part
459A373P3, General Electric , Insulation for Stationary Arcing Contacts , Qty 3 required per breaker , suitable for AK/AKU/AKT-50 air circuit breakers
From Get Price

MDN4083LEA0122NMNA4ENCMPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNA4ENCMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0822NMNJ2NNLNSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNJ2NNLNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MPA31F0801232
General Electric - Insulated Case
MPA31F0801232, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, 24/30V dc motor operator, 48V dc closing coil, 110/130V dc/ac shunt trip and 110/130V ac undervoltage trip, 3P, 3PH, 800A, 690V, 50kA@415V, Bolt-On, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers
From Get Price