1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
MDN4083LEA0822NMNF2EHNDSX
MDN4083LEA0822NMNF2EHNDSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNF2EHNDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SKLL3608L4P8
SKLL3608L4P8
General Electric - Molded Case
SKLL3608L4P8 General Electric Spectra Series, type , 3P, 3PH, 800A, 600V, 65kA@480V, extra high interrupting capacity, 100% rated, UL listed, suitable for reverse fed applications, complete with microEntelliGuard trip unit with LSIG, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault and ZSI, zone selective interlocking & RELT, reduced energy let-through trip functions and advanced metering, modbus, waveform capture & protective relays communication features, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNR4NNCCWX
MDN4083LEA0422NMNR4NNCCWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNR4NNCCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
E6L-A50-4P-3200A-DO-EO-LSIG
E6L-A50-4P-3200A-DO-EO-LSIG
ABB - Insulated Case
E6L-A50-4P-3200A-DO-EO-LSIG, ABB, EMax, type , 4P, 3PH, 5000A frame, 3200A rating plug, 600V, 150kA@480V, Draw-Out, electrically operated, Solid State electronic with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
SEHF361800LIES1D4
SEHF361800LIES1D4
Square D - Insulated Case
SEHF361800LIES1D4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1800A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & shunt trip along with 2A2B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0822NMNX2YNHCAX
MDN4083LEA0822NMNX2YNHCAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNX2YNHCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SPB65-3P-1000A-MO-BO-LSIG
SPB65-3P-1000A-MO-BO-LSIG
Cutler Hammer - Insulated Case
SPB65-3P-1000A-MO-BO-LSIG, Cutler Hammer, Systems Pow-R, type , 1600A frame size, 3P, 3PH, 1000A, 600V, 65kA@480V, standard interrupting capacity, Bolt-On, electrically operated, available with Pow-R Trip, Pow-R Trip 7, Digitrip RMS 510, 610, 810, 910, Digitrip OPTIM 750 and 1050, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
WLL2D316EW
WLL2D316EW
Siemens - Insulated Case
WLL2D316EW, Siemens, WL Series, type , frame size II, drawout, 3P, 3PH, 1600A, 600V, 100kA@480V, UL listed, high interrupting capacity, Draw-Out, complete with solid state ETU755 programmer + WLGFA76 ground fault module, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions and 315A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNC2NNAMSX
MDN4083LEA0522NMNC2NNAMSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNC2NNAMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0522NMNK4YNRDCX
MDN4083LEA0522NMNK4YNRDCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNK4YNRDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0422NMNR2NHNCAX
MDN4083LEA0422NMNR2NHNCAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNR2NHNCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SED36300LSIES7F8
SED36300LSIES7F8
Square D - Insulated Case
SED36300LSIES7F8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 300A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 125VDC shunt trip along with 2 N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SHD1G357K
SHD1G357K
General Electric - Insulated Case
SHD1G357K, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication & ZSI features and 600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHD6G9A8W
SHD6G9A8W
General Electric - Insulated Case
SHD6G9A8W, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 150kA@480V, high interrupting capacity, Draw-Out, 3000A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering & RELT features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SEHF364000LSGB8
SEHF364000LSGB8
Square D - Insulated Case
SEHF364000LSGB8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 4000A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, complete with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0722NMNJ4YNLCAX
MDN4083LEA0722NMNJ4YNLCAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNJ4YNLCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNH2NNKCPX
MDN4083LEA0722NMNH2NNKCPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNH2NNKCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SSB1G1K8C
SSB1G1K8C
General Electric - Insulated Case
SSB1G1K8C, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering & ZSI features and 200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SEHD361800ES6C4
SEHD361800ES6C4
Square D - Insulated Case
SEHD361800ES6C4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1800A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 48VDC shunt trip along with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0422NMNE2YNYNPX
MDN4083LEA0422NMNE2YNYNPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNE2YNYNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0422NMNGNENNCSX
MDN4083LEA0422NMNGNENNCSX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNGNENNCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals and latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassette, with shutters and unwired
From Get Price
Limited Stock
PGFE4ATEL0400
PGFE4ATEL0400
General Electric - Molded Case
PGFE4ATEL0400, General Electric, GuardEon, type , 3PH, 4P, 600V, 120-400A, 35kA@480V, front connection/Feed-Thru, toggle mechanism, complete with PremEon G advanced metering interchangeable trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, Solid State electronic, molded case circuit breakers; meet UL, cUL, IEC, CE, CCC requirements
From Get Price
Limited Stock
MPA31F10W2400
MPA31F10W2400
General Electric - Air
MPA31F10W2400, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50H trip unit, 48V dc motor operator and 220/250V dc/ac closing coil, 3P, 3PH, 1000A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, air circuit breakers
From Get Price
Limited Stock
SEHF361800LSGES9E4
SEHF361800LSGES9E4
Square D - Insulated Case
SEHF361800LSGES9E4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1800A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & 24VDC shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price