REF3A100L
Miami Breaker - Molded Case
REF3A100L, Miami Breaker, REF Series, type , 3P, 3PH, 100A, 600V, 14kA@480V, standard interrupting capacity, Feed-Thru, complete with I - Instantaneous protection only and line & load side lug terminals, standard magnetic range, MCP, motor circuit protectors, Magnetic Only, molded case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price

TFKHM1
General Electric - Part And Accessory
TFKHM1, General Electric, TDM Model, circuit breaker accessory, Operating Handles, rotary level handle mechanism, handle included, door-mounted, handle mounting location right, handle to device connection 5-7/8 inch fixed depth shaft, shallow mount, NEMA 1/3R/12, suitable for use with TFC,TFJ,TFK,THFK type molded case circuit breakers
From Get Price

8539SFR3V08
Square D - Motor Starter
8539SFR3V08, Square D, Class 8539, combination non-reversing motor starter, NEMA size 00, requires 3 thermal units, supplied with 125A KAL thermal magnetic circuit breaker and NEMA type 7 & 9 spin top type enclosure, 3P, 3PH, 600V, 30 HP @ 208V, complete with 208V coil, suitable for use with Class 8539 motor control systems
From Get Price

AKR-11D-50H-MO-DO-LI
General Electric - Air
AKR-11D-50H-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with EntelliGuard Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

PA2700PRT
Westinghouse - Trip Units And Programmers
PA2700PRT, Westinghouse, TRI-PAC, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 700A, suitable for Tri-Pac PB,PA 1600A molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

REE1B010L
Miami Breaker - Molded Case
REE1B010L, Miami Breaker, REE Series, type , 1P, 1PH, 10A, 120V, 10kA@120V, standard interrupting capacity, Feed-Thru, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, molded case circuit breakers; these breakers are now obsolete, however we do still stock them
From Get Price

8539SCW51V08
Square D - Motor Starter
8539SCW51V08, Square D, Class 8539, combination non-reversing motor starter, NEMA size 1, requires 3 thermal units, supplied with MAG-GARD GJL36003-M01 circuit breaker and NEMA type 4X enclosure, 3P, 3PH, 600V, 1/4-1/3 HP @ 208V, complete with 208V coil, suitable for use with Class 8539 motor control systems
From Get Price

REE1B045
Miami Breaker - Molded Case
REE1B045, Miami Breaker, REE Series, type , 1P, 1PH, 45A, 120V, 10kA@120V, standard interrupting capacity, Bolt-On, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, Thermal Magnetic, molded case circuit breakers; these breakers are now obsolete, however we do still stock them
From Get Price

TR4C250GFD
General Electric - Rating Plug
TR4C250GFD, General Electric, Power Break II, type , interchangeable rating plug element, rated for 250A, suitable for use with 400A ground fault rated Power Plus programmer trip device, designed to defeat the ground fault function, to be used with PBII & WavePro - SSD,SHD,SSF,SHF,WPS,WPH,WPF,WPX circuit breaker frame types
From Get Price

REE3B125L
Miami Breaker - Molded Case
REE3B125L, Miami Breaker, REE Series, type , 3P, 3PH, 125A, 240V, 10kA@240V, standard interrupting capacity, Feed-Thru, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, molded case circuit breakers; these breakers are now obsolete, however we do still stock them
From Get Price

HLA3250PT
Westinghouse - Trip Units And Programmers
HLA3250PT, Westinghouse, TRI-PAC, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 250A, suitable for 400A- LA,HLA Tri-Pac molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price

21-A132FB1
Eaton - Mounting Hardware
21-A132FB1, Hardware Resource Company, Eaton, Westinghouse, Cutler Hammer, direct replacement mounting hardware for Westinghouse CDP bolt-on style panel boards, rated for 150A 600V max, Copper, Dual/Twin Branch mounting style, suitable for use with EB,EHB,FB,HFB,MCP circuit breaker frames, complete with all associated hardware, screws and cover plates
From Get Price

REE2B015L
Miami Breaker - Molded Case
REE2B015L, Miami Breaker, REE Series, type , 2P, 1PH, 15A, 240V, 10kA@240V, standard interrupting capacity, Feed-Thru, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, molded case circuit breakers; these breakers are now obsolete, however we do still stock them
From Get Price

REH2B020L
Miami Breaker - Molded Case
REH2B020L, Miami Breaker, REH Series, type , 2P, 1PH, 20A, 480V, 14kA@480V, standard interrupting capacity, Feed-Thru, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, molded case circuit breakers; these breakers are now obsolete, however we do still stock them
From Get Price

ECN2214EAE
Cutler Hammer - Motor Starter
ECN2214EAE, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP, type , 3P, 3PH, 5 HP @ 200V, 600V, complete with 208V coil, NEMA size 1, 30A HMCP circuit breaker enclosed in NEMA Type 4X 304-grade watertight & dust-tight stainless steel enclosure, suitable for use with Freedom Series motor control systems
From Get Price

8739SDW1V02SH30
Square D - Motor Starter
8739SDW1V02SH30, Square D, Class 8739, type , full voltage reversing motor starter with HLL 60A thermal magnetic circuit breaker, 3P, 3PH, 20HP @ 480V, 25HP @ 600V, 600V with 120V 60Hz/110V 50Hz coil, NEMA size 2, includes NEMA 4 & 4X watertight and dust-tight stainless steel enclosure and Motor Logic SSOLR Class 10/20
From Get Price

ECN24A5BAD
Cutler Hammer - Motor Starter
ECN24A5BAD, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP and CPT (control power transformers), type , 3P, 3PH, 1.5 HP @ 230V, 600V, complete with 240V coil, NEMA size 00, 15A HMCP circuit breaker enclosed in NEMA Type 4 nonmetallic enclosure, suitable for use with Freedom Series motor control systems
From Get Price

REH2B100L
Miami Breaker - Molded Case
REH2B100L, Miami Breaker, REH Series, type , 2P, 1PH, 100A, 480V, 14kA@480V, standard interrupting capacity, Feed-Thru, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, molded case circuit breakers; these breakers are now obsolete, however we do still stock them
From Get Price

8539SDW52V03
Square D - Motor Starter
8539SDW52V03, Square D, Class 8539, combination non-reversing motor starter, NEMA size 2, requires 3 thermal units, supplied with MAG-GARD GJL36030-M04 circuit breaker and NEMA type 4X enclosure, 3P, 3PH, 600V, 5-7 1/2 HP @ 240V, complete with 240V coil, suitable for use with Class 8539 motor control systems
From Get Price

AKR-4B-50H-MO-DO-LI
General Electric - Air
AKR-4B-50H-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with SST Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

REF2B070L
Miami Breaker - Molded Case
REF2B070L, Miami Breaker, REF Series, type , 2P, 1PH, 70A, 600V, 14kA@480V, standard interrupting capacity, Feed-Thru, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, molded case circuit breakers; these breakers are now obsolete, however we do still stock them
From Get Price

EC22221AAF
Cutler Hammer - Motor Starter
EC22221AAF, Cutler Hammer, A200 Series, combination, non-reversing motor starter with HMCP, type , 3P, 3PH, 10 HP @ 200V, 10 HP @ 230V, 25 HP @ 460V, 600V, complete with 120V coil, NEMA size 2, 50A HMCP circuit breaker enclosed in NEMA Type 1 enclosure, suitable for use with A200 Series motor control systems
From Get Price

REF3L030L
Miami Breaker - Molded Case
REF3L030L, Miami Breaker, REF Series, type , 3P, 3PH, 30A, 600V, 14kA@480V, standard interrupting capacity, Feed-Thru, complete with I - Instantaneous protection only and line & load side lug terminals, low magnetic range, MCP, motor circuit protectors, Magnetic Only, molded case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price

8539SFW44V07
Square D - Motor Starter
8539SFW44V07, Square D, Class 8539, combination non-reversing motor starter, NEMA size 4, requires 3 thermal units, supplied with MAG-GARD KAL36250-29M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 50 HP @ 240V, complete with 600V 60Hz/550V 50Hz coil, suitable for use with Class 8539 motor control systems
From Get Price