8539SCG44V08H30
Square D - Motor Starter
8539SCG44V08H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 1, requires 3 thermal units, supplied with MAG-GARD GJL36015-M03 circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 5 HP @ 208V, complete with 208V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price

0282A7350G001
General Electric - Control Part
0282A7350G001, General Electric, PowerVac, Relay-Anti Pump, 250VDC (non-nuclear), VB-1 2,3, ML-18, qty 1 needed per breaker, suitable for VB1 4.16-250 (1200 & 2000A), VB1 4.16-350 (1200, 2000, 3000A), VB1 7.2-500 (1200 & 2000A), VB1 13.8-500 (1200 & 2000A), VB1 13.8-750 (1200 & 2000A), VB1 13.8-1000 (1200, 2000, 3000A) breakers
From Get Price

ECN2409EAD
Cutler Hammer - Motor Starter
ECN2409EAD, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP and CPT (control power transformers), type , 3P, 3PH, 3 HP @ 200V, 600V, complete with 208V coil, NEMA size , 15A HMCP circuit breaker enclosed in NEMA Type 4X 316-grade stainless steel enclosure, suitable for use with Freedom Series motor control systems
From Get Price

EZSGPC3604L5R
General Electric - Molded Case
EZSGPC3604L5R, General Electric, Spectra Series RMS main circuit breaker kit for EntellEon panelboards, type , requires 4X bus space, 3P, 3PH, 400A, 600V, 100kA@480V, UL listed, complete with MicroEntelliGuard trip unit with LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions and RELT, Solid State electronic, molded case circuit breakers
From Get Price

HLB24000TM
Westinghouse - Trip Units And Programmers
HLB24000TM, Westinghouse, MARK 75, type , interchangeable trip unit with I - Instantaneous trip functions, rated for 400A, front adjustable, suitable for 400A- LB,HLB molded case circuit breaker frame types, magnetic trip range 2000-4000A, Magnetic Only trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price

8539SBW43V07H20
Square D - Motor Starter
8539SBW43V07H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size , requires 3 thermal units, supplied with MAG-GARD GJL36015-M03 circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 5 HP @ 600V, complete with 600V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price

140U-JTG3-D25
Allen-Bradley - Trip Units And Programmers
140U-JTG3-D25, Allen-Bradley, Bulletin 140U, type , interchangeable trip units and programmers, LSG - Long-Time, Short-Time and Ground Fault trip functions, rated for 250A, suitable for 250A J2L,J2H,J2G,J2I,J3L,J3H,J3G,J3I,J6L,J6H,J6G,J6I molded case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From Get Price

8539SCA44S8V03H10
Square D - Motor Starter
8539SCA44S8V03H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 1, supplied with MAG-GARD GJL36030-M04 circuit breaker and NEMA type 12/3R oversized enclosure, 3P, 3PH, 600V, 5-7 1/2HP @ 240V, complete with 240V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price

8539SDA53V01
Square D - Motor Starter
8539SDA53V01, Square D, Class 8539, combination non-reversing motor starter, NEMA size 2, requires 3 thermal units, supplied with MAG-GARD GJL36050-M05 circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 10 HP @ 240V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems
From Get Price

BE-TR20B2000
BRAH Electric - Rating Plug
BE-TR20B2000, BRAH Electric, Power Break II, type , aftermarket rating plug, rated for 2000A, 2000A current sensor rating, suitable for use with Power Break II - SSD,SHD,SSF,SHF,WPS,WPH,WPF,WPX,AKR30,AKR30H,AKR50S,AKR50H insulated case circuit breaker frame types, for use with MicroVersaTrip Plus,MicroVersaTrip PM programmers & circuit breakers
From Get Price

8539SFW54V03H30
Square D - Motor Starter
8539SFW54V03H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 4, requires 3 thermal units, supplied with MAG-GARD KAL36250-29M circuit breaker and NEMA type 4X enclosure, 3P, 3PH, 600V, 50 HP @ 240V, complete with 240V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price

8539SCG45V07
Square D - Motor Starter
8539SCG45V07, Square D, Class 8539, combination non-reversing motor starter, NEMA size 1, requires 3 thermal units, supplied with MAG-GARD GJL36050-M05 circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 7 1/2 HP @ 208V, complete with 600V 60Hz/550V 50Hz coil, suitable for use with Class 8539 motor control systems
From Get Price

MP08H-3P-125A-MO-DO-LIG
Merlin Gerin - Insulated Case
MP08H-3P-125A-MO-DO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 800A frame with 250A sensor rating and 125A rating plug, 3P, 3PH, 600V, 65kA@480V, available with STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP trip units, Solid State electronic, insulated case circuit breakers
From Get Price

ECN2218DA7-E13
Cutler Hammer - Motor Starter
ECN2218DA7-E13, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP, type , 3P, 3PH, 7.5 HP @ 575V, 600V, complete with 600V coil, NEMA size 1, 15A HMCP circuit breaker enclosed in horizontal NEMA Type 12 dust-tight industrial enclosure with external reset, suitable for use with Freedom Series motor control systems
From Get Price

NB3700PRTV
Westinghouse - Trip Units And Programmers
NB3700PRTV, Westinghouse, TRI-PAC, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 700A, 50°C, suitable for Tri-Pac 1200A- NB,HNB molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

8539SBG43V02
Square D - Motor Starter
8539SBG43V02, Square D, Class 8539, combination non-reversing motor starter, NEMA size , requires 3 thermal units, supplied with MAG-GARD GJL36015-M03 circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 1 1/2-3 HP @ 240V, complete with 120V 60Hz/110V 50Hz coil, suitable for use with Class 8539 motor control systems
From Get Price

0177C6640G001
General Electric - Primary Current Part
0177C6640G001, General Electric, PowerVac, Stop for Center Phase Vacuum Interrupter, VB-1 1,2,3, ML-18, qty 1 needed per breaker, suitable for VB1 4.16-250 (1200 & 2000A), VB1 4.16-350 (1200, 2000, 3000A), VB1 7.2-500 (1200 & 2000A), VB1 13.8-500 (1200 & 2000A), VB1 13.8-750 (1200 & 2000A), VB1 13.8-1000 (1200, 2000, 3000A) breakers
From Get Price

CR307F204EAA
General Electric - Motor Starter
CR307F204EAA, General Electric, 300 Line, type , 3P, 3PH, 135-200A, 600V, 100 hp, complete with 460V-480V 50/60Hz, AC coil, non-reversing, combination, thermal magnetic circuit breaker type magnetic starter, NEMA size 00 includes NEMA type 12 surface mount enclosure with no external reset, suitable for use with CR307 motor control systems
From Get Price

8539SHA13V06
Square D - Motor Starter
8539SHA13V06, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with 600A type MAL thermal magnetic circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 300 HP @ 480V, complete with 480V coil, suitable for use with Class 8539 motor control systems
From Get Price

EC22233AAG
Cutler Hammer - Motor Starter
EC22233AAG, Cutler Hammer, A200 Series, combination, non-reversing motor starter with HMCP, type , 3P, 3PH, 20 HP @ 200V, 25 HP @ 230V, 50 HP @ 460V, 600V, complete with 120V coil, NEMA size 3, 100A HMCP circuit breaker enclosed in NEMA Type 4 painted steel enclosure, suitable for use with A200 Series motor control systems
From Get Price

8539SFG44V03H20
Square D - Motor Starter
8539SFG44V03H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 4, requires 3 thermal units, supplied with MAG-GARD KAL36250-29M circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 50 HP @ 240V, complete with 240V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price

8539SBR2V06
Square D - Motor Starter
8539SBR2V06, Square D, Class 8539, combination non-reversing motor starter, NEMA size 00, requires 3 thermal units, supplied with 15A type FAL thermal magnetic circuit breaker and NEMA type 7 & 9 spin top type enclosure, 3P, 3PH, 600V, 5 HP @ 480V, complete with 480V coil, suitable for use with Class 8539 motor control systems
From Get Price

HKB31000TM
Westinghouse - Trip Units And Programmers
HKB31000TM, Westinghouse, MARK 75, type , interchangeable trip unit with I - Instantaneous trip functions, rated for 250A, front adjustable, suitable for 250A- KB,HKB molded case circuit breaker frame types, magnetic trip range 500-1000A, Magnetic Only trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From $279.34

HNB38000TM
Westinghouse - Trip Units And Programmers
HNB38000TM, Westinghouse, MARK 75, type , interchangeable trip unit with I - Instantaneous trip functions, front adjustable, rated for 1200A, suitable for NB,HNB,NBY 1200A molded case circuit breaker frame types, magnetic trip range 4000-8000A, Magnetic Only trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price