


- Home /
15 amp breaker
97,864 Results
Refine Results
In Stock
Subcategory
SORT BY

MP08H-3P-125A-MO-BO-LIG
Merlin Gerin - Insulated Case
MP08H-3P-125A-MO-BO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 800A frame with 250A sensor rating and 125A rating plug, 3P, 3PH, 600V, 65kA@480V, available with STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP trip units, Solid State electronic, insulated case circuit breakers
From Get Price

8539SFA16V07
Square D - Motor Starter
8539SFA16V07, Square D, Class 8539, combination non-reversing motor starter, NEMA size 4, requires 3 thermal units, supplied with 100A type FAL thermal magnetic circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 60 HP @ 600V, complete with 600V coil, suitable for use with Class 8539 motor control systems
From Get Price

AKR-9A-30S-MO-DO-LI
General Electric - Air
AKR-9A-30S-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with MicroVersa Trip Plus - Gen1 Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

8539SDG43V04H10
Square D - Motor Starter
8539SDG43V04H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 2, requires 3 thermal units, supplied with MAG-GARD GJL36050-M05 circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 10 HP @ 240V, complete with 277V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price

ECN2419EAC
Cutler Hammer - Motor Starter
ECN2419EAC, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP and CPT (control power transformers), type , 3P, 3PH, 1 HP @ 200V, 600V, complete with 208V coil, NEMA size 1, 7A HMCP circuit breaker enclosed in NEMA Type 4X 316-grade stainless steel enclosure, suitable for use with Freedom Series motor control systems
From Get Price

8539SCR42V08
Square D - Motor Starter
8539SCR42V08, Square D, Class 8539, combination non-reversing motor starter, NEMA size 00, requires 3 thermal units, supplied with MAG-GARD GJL36007-M02 circuit breaker and NEMA type 7 & 9 spin top type enclosure, 3P, 3PH, 600V, 1/2-1 HP @ 208V, complete with 208V coil, suitable for use with Class 8539 motor control systems
From Get Price

8539SHA17V06
Square D - Motor Starter
8539SHA17V06, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with 800A type MAL thermal magnetic circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 400 HP @ 480V, complete with 480V coil, suitable for use with Class 8539 motor control systems
From Get Price

8739SGA14V02SH30
Square D - Motor Starter
8739SGA14V02SH30, Square D, Class 8739, type , full voltage reversing motor starter with LLL 400A thermal magnetic circuit breaker, 3P, 3PH, 125-150HP @ 480V, 200HP @ 600V, 600V with 120V 60Hz/110V 50Hz coil, NEMA size 5, includes NEMA 12/3R dust-tight industrial use enclosure with external reset, Motor Logic SSOLR Class 10/20
From Get Price

AKR-6D-75-MO-DO-LI
General Electric - Air
AKR-6D-75-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 3200A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with MicroVersa Trip Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

8539SBW53V07H30
Square D - Motor Starter
8539SBW53V07H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size , requires 3 thermal units, supplied with MAG-GARD GJL36015-M03 circuit breaker and NEMA type 4X enclosure, 3P, 3PH, 600V, 5 HP @ 600V, complete with 600V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price

AKR-5C-100-MO-DO-LI
General Electric - Air
AKR-5C-100-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 4000A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with ECS Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

AKR-5S-30-MO-BI-LI
General Electric - Air
AKR-5S-30-MO-BI-LI, General Electric, Manually Operated, Bolt-In, Low Voltage air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with ECS Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

PB32000PT
Westinghouse - Trip Units And Programmers
PB32000PT, Eaton, Westinghouse, Cutler Hammer, TRI-PAC, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 2000A, suitable for Tri-Pac PB,PA 2000A molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

8539SHA16V07
Square D - Motor Starter
8539SHA16V07, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with 350A type MAL thermal magnetic circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 250 HP @ 600V, complete with 600V coil, suitable for use with Class 8539 motor control systems
From Get Price

CR307B204GAA
General Electric - Motor Starter
CR307B204GAA, General Electric, 300 Line, type , 3P, 3PH, 18-20A, 600V, 5 hp, complete with 460V-480V 50/60Hz, AC coil, non-reversing, combination, thermal magnetic circuit breaker type magnetic starter, NEMA size 00 includes NEMA type 12 surface mount enclosure with no external reset, suitable for use with CR307 motor control systems
From Get Price

TQL2125
General Electric - Molded Case
TQL2125, General Electric, Q-Line, type , 2P, 1PH, 120/240V, 25A, 5kA@240V, UL listed, standard interrupting capacity, Plug-In, LI - Long-Time and Instantaneous trip functions, load side lug terminals, for use with PowerMark circuit breaker load centers, Thermal Magnetic, molded case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price

150-DH-VR-750-1200A
Westinghouse - Vacuum Circuit Breaker
150-DH-VR-750-1200A, Westinghouse, DH-VR Series, , 3PH, 3P, 15000 VAC, 1200 Frame, Electrically Operated, Draw-Out, Medium Voltage vacuum circuit breaker Retrofit, Retrofitted for 150-DH-750, For Use In De-ion DH Switchgear. Operating Voltage, Control Voltages, Wiring, and Additional Accessories to be determined before ordering.
From Get Price

ASKP3
Siemens - Auxiliary
ASKP3, Siemens, VL Series, type , auxiliary, (2) 2A + 2B auxiliary switches and (2) alarm switches combo, bases AMBP2, mounts in left side pocket only, when installed in circuit breaker, the part number suffix is -A3, suitable for use with NMG,HMG,LMG,NNG,HNG,LNG,NPG,HPG,LPG frame molded case circuit breakers
From Get Price

MP08H-3P-125A-MO-DO-LI
Merlin Gerin - Insulated Case
MP08H-3P-125A-MO-DO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 800A frame with 250A sensor rating and 125A rating plug, 3P, 3PH, 600V, 65kA@480V, available with STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP trip units, Solid State electronic, insulated case circuit breakers
From Get Price

8539SEW52V06H10
Square D - Motor Starter
8539SEW52V06H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 3, requires 3 thermal units, supplied with MAG-GARD FAL36100-18M circuit breaker and NEMA type 4X enclosure, 3P, 3PH, 600V, 30-50 HP @ 480V, complete with 480V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price

8539SBT43V03
Square D - Motor Starter
8539SBT43V03, Square D, Class 8539, combination non-reversing motor starter, NEMA size 00, requires 3 thermal units, supplied with MAG-GARD GJL36015-M03 circuit breaker and NEMA type 7 & 9 bolted type enclosure, 3P, 3PH, 600V, 1 1/2-3 HP @ 240V, complete with 240V coil, suitable for use with Class 8539 motor control systems
From Get Price

8539SCG44V08H20
Square D - Motor Starter
8539SCG44V08H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 1, requires 3 thermal units, supplied with MAG-GARD GJL36015-M03 circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 5 HP @ 208V, complete with 208V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price

MP20-3P-2000A
Merlin Gerin - Insulated Case
MP20-3P-2000A, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2000A frame includes 2000A sensor rating with 2000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

20RS12T
Cutler Hammer - Rating Plug
20RS12T, Cutler Hammer, Series C, type , adjustable interchangeable rating plug element, rated for 1200A, suitable for use with 2000A current sensor rating, to be used with Series C RD,RDC,CRD,CRDC molded case circuit breaker frame types, for use with Seltronic type RS RS32000T, RS32000TG, RS42000T solid state electronic trip units & circuit breakers
From Get Price