- Home /
15 amp breaker
97,864 Results
Refine Results
In Stock
Subcategory
SORT BY

2603D47G07
Westinghouse - Trip Units And Programmers
2603D47G07, Westinghouse, MARK 75, type , interchangeable trip unit with I - Instantaneous only trip functions, rated for 600A, front adjustable, suitable for 600A- LA,HLA molded case circuit breaker frame types, magnetic trip range 1125-2250A, Magnetic Only trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From $644.78

AKR-5F-100-MO-DO-LI
General Electric - Air
AKR-5F-100-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 4000A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with ECS Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

MP63H-3P-6000A
Merlin Gerin - Insulated Case
MP63H-3P-6000A, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 6300A frame, includes 6300A sensor rating with 6000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

8539SFW44V03H10
Square D - Motor Starter
8539SFW44V03H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 4, requires 3 thermal units, supplied with MAG-GARD KAL36250-29M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 50 HP @ 240V, complete with 240V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price

MP08H-3P-125A-EO-BO-LS
Merlin Gerin - Insulated Case
MP08H-3P-125A-EO-BO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 800A frame with 250A sensor rating and 125A rating plug, 3P, 3PH, 600V, 65kA@480V, available with STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP trip units, Solid State electronic, insulated case circuit breakers
From Get Price

CR307D204NAA
General Electric - Motor Starter
CR307D204NAA, General Electric, 300 Line, type , 3P, 3PH, 45-70A, 600V, 25 hp, complete with 460V-480V 50/60Hz, AC coil, non-reversing, combination, thermal magnetic circuit breaker type magnetic starter, NEMA size 00 includes NEMA type 12 surface mount enclosure with no external reset, suitable for use with CR307 motor control systems
From Get Price

8539SCT41V06
Square D - Motor Starter
8539SCT41V06, Square D, Class 8539, combination non-reversing motor starter, NEMA size 00, requires 3 thermal units, supplied with MAG-GARD GJL36003-M01 circuit breaker and NEMA types 7 & 9 bolted type enclosure, 3P, 3PH, 600V, 1/4-1 HP @ 480V, complete with 480V coil, suitable for use with Class 8539 motor control systems
From Get Price

8539SCT43V08
Square D - Motor Starter
8539SCT43V08, Square D, Class 8539, combination non-reversing motor starter, NEMA size 00, requires 3 thermal units, supplied with MAG-GARD GJL36015-M03 circuit breaker and NEMA type 7 & 9 bolted type enclosure, 3P, 3PH, 600V, 1 1/2-3 HP @ 208V, complete with 208V coil, suitable for use with Class 8539 motor control systems
From Get Price

AKR-9S-30H-MO-BI-LI
General Electric - Air
AKR-9S-30H-MO-BI-LI, General Electric, Manually Operated, Bolt-In, Low Voltage air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with MicroVersa Trip Plus - Gen1 Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

8539SHA56V08
Square D - Motor Starter
8539SHA56V08, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD MAL36600-44M circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 200 HP @ 240V, complete with 208V 60Hz coil, suitable for use with Class 8539 motor control systems
From Get Price

8539SBA52V07
Square D - Motor Starter
8539SBA52V07, Square D, Class 8539, combination non-reversing motor starter, NEMA size , requires 3 thermal units, supplied with MAG-GARD GJL36007-M02 circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 1 1/2-3 HP @ 600V, complete with 600V coil, suitable for use with Class 8539 motor control systems
From Get Price

LGL36250U31X
Square D - Molded Case
LGL36250U31X, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 250A, 600V, 35kA@480V, UL listed, high interrupting capacity, Feed-Thru, can used for 2P applications, complete with non-interchangeable micrologic standard 3.3 trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Solid State electronic, molded case circuit breaker
From Get Price

8539SGW44V08H20
Square D - Motor Starter
8539SGW44V08H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 5, requires 3 thermal units, supplied with MAG-GARD LAL36400-32M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 60 HP @ 208V, complete with 208V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price

AKR-4F-75-MO-DO-LI
General Electric - Air
AKR-4F-75-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 3200A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with SST Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

8539SDA53S8V08H30
Square D - Motor Starter
8539SDA53S8V08H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 2, supplied with MAG-GARD GJL36050-M05 circuit breaker and NEMA type 12/3R oversized enclosure, 3P, 3PH, 600V, 71/2-10HP @ 208V, complete with 208V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price

8539SFR1V07
Square D - Motor Starter
8539SFR1V07, Square D, Class 8539, combination non-reversing motor starter, NEMA size 00, requires 3 thermal units, supplied with 150A type KAL thermal magnetic circuit breaker and NEMA type 7 & 9 spin top type enclosure, 3P, 3PH, 600V, 100 HP @ 600V, complete with 600V coil, suitable for use with Class 8539 motor control systems
From Get Price

8539SBW53V02
Square D - Motor Starter
8539SBW53V02, Square D, Class 8539, combination non-reversing motor starter, NEMA size , requires 3 thermal units, supplied with MAG-GARD GJL36015-M03 circuit breaker and NEMA type 4X enclosure, 3P, 3PH, 600V, 1 1/2-3 HP @ 240V, complete with 120V 60Hz/110V 50Hz coil, suitable for use with Class 8539 motor control systems
From Get Price

EC22213AAD
Cutler Hammer - Motor Starter
EC22213AAD, Cutler Hammer, A200 Series, combination, non-reversing motor starter with HMCP, type , 3P, 3PH, 3 HP @ 200V, 3 HP @ 230V, 5 HP @ 460V, 600V, complete with 120V coil, NEMA size 1, 15A HMCP circuit breaker enclosed in NEMA Type 4 painted steel enclosure, suitable for use with A200 Series motor control systems
From Get Price

8539SFA52V07
Square D - Motor Starter
8539SFA52V07, Square D, Class 8539, combination non-reversing motor starter, NEMA size 4, requires 3 thermal units, supplied with MAG-GARD KAL36250-25M circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 60-100 HP @ 600V, complete with 600V coil, suitable for use with Class 8539 motor control systems
From Get Price

AKR-6D-30-MO-DO-LI
General Electric - Air
AKR-6D-30-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with MicroVersa Trip Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

8739SFA5V06H30
Square D - Motor Starter
8739SFA5V06H30, Square D, Class 8739, type , full voltage reversing motor starter with JJL 150A thermal magnetic circuit breaker, 3P, 3PH, 60HP @ 480V, 60-75HP @ 600V, 600V with 480V 60Hz/440V 50Hz coil, NEMA size 4, includes NEMA 12/3R dust-tight industrial use enclosure without external reset, Motor Logic SSOLR Class 10/20
From Get Price

FGRL3NN0400-7
General Electric - Rating Plug
FGRL3NN0400-7, General Electric, Record Plus, type , adjustable LT & LTD settable rating plug element for SMR2 trip units, 436726, rated for 400A, suitable for use with 3-pole FG 630A- FGN,FGH,FGL molded case circuit breaker frame types, for use with 3-pole SMR2 selective solid state electronic trip units & circuit breakers
From Get Price

CR307G203BAA
General Electric - Motor Starter
CR307G203BAA, General Electric, 300 Line, type , 3P, 3PH, 270-300A, 600V, 75 hp, complete with 230V-240V 50/60Hz, AC coil, non-reversing, combination, thermal magnetic circuit breaker type magnetic starter, NEMA size 00 includes NEMA type 12 surface mount enclosure with no external reset, suitable for use with CR307 motor control systems
From Get Price

AKR-11AE-50-MO-DO-LI
General Electric - Air
AKR-11AE-50-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with EntelliGuard Solid State Overcurrent Protection, LI - Long Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price