


- Home /
15 amp breaker
97,864 Results
Refine Results
In Stock
Subcategory
SORT BY

8539SDW52V04H20
Square D - Motor Starter
8539SDW52V04H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 2, requires 3 thermal units, supplied with MAG-GARD GJL36030-M04 circuit breaker and NEMA type 4X enclosure, 3P, 3PH, 600V, 5-7 1/2 HP @ 240V, complete with 277V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price

MWI6163HEA1622NMNA2EMNNAX
Eaton - Air
MWI6163HEA1622NMNA2EMNNAX, Cutler Hammer, Eaton, Magnum IEC Type , Standard frame, 65kV@690V interrupting rating, 1600A, 3-Pole, Fixed Horizontal mounting, 1600 rating plug, {current limiter} current limiter, 520 LSI trip unit, No shunt trip, Manual operated motor operator, No SRD, 2A/2B auxiliary switch, Metal (block close and open) padlock, No counter - no locks key lock, air circuit breaker
From Get Price

8539SCW44V04H10
Square D - Motor Starter
8539SCW44V04H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 1, requires 3 thermal units, supplied with MAG-GARD GJL36030-M04 circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 5-7 1/2 HP @ 240V, complete with 277V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price

CR306GXQ023
General Electric - Motor Starter
CR306GXQ023, General Electric, 300 Line, type , 3P, 3PH, 270A, 600V, 75 hp, complete with 200V-208V 50/60Hz, AC coil, non-reversing, non-combination open type magnetic starter, NEMA size 5, equipped with overload rely to provide 130.0-270.0A with 600 max fuse rating, 800 max breaker rating, suitable for use with CR306 motor control systems
From Get Price

MP63H-3P-6300A-MO-BO-LSIG
Merlin Gerin - Insulated Case
MP63H-3P-6300A-MO-BO-LSIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 6300A frame, includes 6300A sensor rating with 6300A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

LA2100T
Westinghouse - Trip Units And Programmers
LA2100T, Westinghouse, LA Series, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 100A, suitable for 400A- LA,HLA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From $364.55

MP16-3P-1600A-EO-BO-LS
Merlin Gerin - Insulated Case
MP16-3P-1600A-EO-BO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1600A frame includes 1600A trip with 1600A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

CR306EXM003
General Electric - Motor Starter
CR306EXM003, General Electric, 300 Line, type , 3P, 3PH, 90A, 600V, 30 hp, complete with 230V-240V 50/60Hz, AC coil, non-reversing, non-combination open type magnetic starter, NEMA size 3, equipped with overload rely to provide 65.0-135.0A with 500 max fuse rating, 400 max breaker rating, suitable for use with CR306 motor control systems
From Get Price

HKA3090TA
Westinghouse - Trip Units And Programmers
HKA3090TA, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 90A, 50°C, suitable for 225A- KA,HKA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

ECN2208CAD-E3R5
Cutler Hammer - Motor Starter
ECN2208CAD-E3R5, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP, type , 3P, 3PH, 5 HP @ 460V, 600V, complete with 480V coil, NEMA size , 15A HMCP circuit breaker enclosed in oversize NEMA Type 12 dust-tight industrial enclosure with internal reset, without control transformer, suitable for use with Freedom Series motor control systems
From Get Price

A20PCG1800
Westinghouse - Rating Plug
A20PCG1800, Westinghouse, SELTRONIC, type , adjustable rating plug element, rated for 1800A, adjustable magnetic trip setting 3200-12800A, suitable for use with 2000A Seltronic - PCG,PCGA,PCCG,PCCGA molded case circuit breaker frame types, for use with Seltronic solid state electronic trip units & circuit breakers; these rating plugs are obsolete; however we do still stock them
From Get Price

8539SDG43V08H10
Square D - Motor Starter
8539SDG43V08H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 2, requires 3 thermal units, supplied with MAG-GARD GJL36050-M05 circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 7 1/2-10 HP @ 208V, complete with 208V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price

8539SGG45V02H20
Square D - Motor Starter
8539SGG45V02H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 5, requires 3 thermal units, supplied with MAG-GARD LAL36400-33M circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 75 HP @ 208V, complete with 120V 60Hz/110V 50Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price

8539SGA54V03H20
Square D - Motor Starter
8539SGA54V03H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 5, requires 3 thermal units, supplied with MAG-GARD LAL36400-32M circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 75 HP @ 240V, complete with 240V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price

AKR-8B-100-MO-DO-LSG
General Electric - Air
AKR-8B-100-MO-DO-LSG, General Electric, Manually Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 4000A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with Epic MicroVersa Trip Solid State Overcurrent Protection, LSG - Long-Time, Short-Time and Ground Fault trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

MP08-3P-125A-EO-DO-LSI
Merlin Gerin - Insulated Case
MP08-3P-125A-EO-DO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 800A frame with 250A trip and 125A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

ECN2454CAJ
Cutler Hammer - Motor Starter
ECN2454CAJ, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP and CPT (control power transformers), type , 3P, 3PH, 125 HP @ 460V, 600V, complete with 480V coil, NEMA size 5, 250A HMCP circuit breaker enclosed in NEMA Type 4X 304-grade watertight & dust-tight stainless steel enclosure, suitable for use with Freedom Series motor control systems
From Get Price

A25PCG1800
Westinghouse - Rating Plug
A25PCG1800, Westinghouse, SELTRONIC, type , adjustable rating plug element, rated for 1800A, adjustable magnetic trip setting 3600-14400A, suitable for use with 2500A Seltronic - PCG,PCGA,PCCG,PCCGA molded case circuit breaker frame types, for use with Seltronic solid state electronic trip units & circuit breakers; these rating plugs are obsolete; however we do still stock them
From Get Price

8539SHW45V04H30
Square D - Motor Starter
8539SHW45V04H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD MAL36600-42M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 150 HP @ 208V, complete with 277V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price

8539SGW45V03H30
Square D - Motor Starter
8539SGW45V03H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 5, requires 3 thermal units, supplied with MAG-GARD LAL36400-33M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 75 HP @ 208V, complete with 240V 60Hz/220V 50Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price

HKA2070TV
Westinghouse - Trip Units And Programmers
HKA2070TV, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 70A, 50°C, suitable for 225A- KA,HKA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

8539SHA56V01H10
Square D - Motor Starter
8539SHA56V01H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD MAL36600-44M circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 200 HP @ 240V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price

MP32H2-3P-3200A-EO-BO-LI
Merlin Gerin - Insulated Case
MP32H2-3P-3200A-EO-BO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3200A frame, includes 3200A sensor rating with 3200A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

8539SHG46V02H20
Square D - Motor Starter
8539SHG46V02H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD LAL36600-44M circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 200 HP @ 240V, complete with 120V 60Hz/110V 50Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price