Limited Stock
MA2450TA
MA2450TA
Westinghouse - Trip Units And Programmers
MA2450TA, Westinghouse, MA Series, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 450A, 50°C, suitable for 800A- MA,HMA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
Limited Stock
A12NCG1200
A12NCG1200
Westinghouse - Rating Plug
A12NCG1200, Westinghouse, SELTRONIC, type , adjustable rating plug element, rated for 1200A, adjustable magnetic trip setting 1600-6400A, suitable for use with 1200A Seltronic - NCG,NCGA,HNCG,HNCGA molded case circuit breaker frame types, for use with Seltronic solid state electronic trip units & circuit breakers; these rating plugs are obsolete; however we do still stock them
From Get Price
Limited Stock
8539SCW54V01H30
8539SCW54V01H30
Square D - Motor Starter
8539SCW54V01H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 1, requires 3 thermal units, supplied with MAG-GARD GJL36030-M04 circuit breaker and NEMA type 4X enclosure, 3P, 3PH, 600V, 5-7 1/2 HP @ 240V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price
Limited Stock
8539SFW44V02H30
8539SFW44V02H30
Square D - Motor Starter
8539SFW44V02H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 4, requires 3 thermal units, supplied with MAG-GARD KAL36250-29M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 50 HP @ 240V, complete with 120V 60Hz/110V 50Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price
Limited Stock
TQP225CL
TQP225CL
General Electric - Molded Case
TQP225CL, General Electric, PowerMark, type , 2P, 1PH, 120/240V, 25A, 5kA@240V, UL listed, standard interrupting capacity, enclosure compensated, Plug-In, LI - Long-Time and Instantaneous trip functions, copper load side lug terminals, for use with PowerMark circuit breaker load centers, Thermal Magnetic molded case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
MP08H2-3P-300A
MP08H2-3P-300A
Merlin Gerin - Insulated Case
MP08H2-3P-300A, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 800A frame, includes 250A, 400A or 600A sensor rating with 300A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
ECN2404DA6
ECN2404DA6
Cutler Hammer - Motor Starter
ECN2404DA6, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP and CPT (control power transformers), type , 3P, 3PH, 3 HP @ 575V, 600V, complete with 600V coil, NEMA size , 7A HMCP circuit breaker enclosed in NEMA Type 4X 304-grade watertight & dust-tight stainless steel enclosure, suitable for use with Freedom Series motor control systems
From Get Price
Limited Stock
8539SCW55V07H20
8539SCW55V07H20
Square D - Motor Starter
8539SCW55V07H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 1, requires 3 thermal units, supplied with MAG-GARD GJL36050-M05 circuit breaker and NEMA type 4X enclosure, 3P, 3PH, 600V, 7 1/2 HP @ 208V, complete with 600V 60Hz/550V 50Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price
Limited Stock
48814
48814
Merlin Gerin - Trip Units And Programmers
48814, Square D, Schneider Electric, Merlin Gerin, Micrologic, field installable, S141A, Micrologic standard 3.0A trip unit with LI - Long-Time and Instantaneous trip functions and ammeter, with type 'A' rating plug, suitable for NS,NT,NW,PG,PJ,PK,PL,RG,RJ,RK,RL molded case & insulated case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From Get Price
In Stock
CR306EXL004
CR306EXL004
General Electric - Motor Starter
CR306EXL004, General Electric, 300 Line, type , 3P, 3PH, 90A, 600V, 50 hp, complete with 460V-480V 50/60Hz, AC coil, non-reversing, non-combination open type magnetic starter, NEMA size 3-4, equipped with overload rely to provide 35.0-70.0A with 250 max fuse rating, 250 max breaker rating, suitable for use with CR306 motor control systems
From $563.24
Limited Stock
MP20H-3P-2000A-MO-DO-LSIG
MP20H-3P-2000A-MO-DO-LSIG
Merlin Gerin - Insulated Case
MP20H-3P-2000A-MO-DO-LSIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2000A frame, includes 2000A sensor rating with 2000A rating plug, 3P, 3PH, 600V, 75kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP63H-3P-6000A-EO-DO-LSI
MP63H-3P-6000A-EO-DO-LSI
Merlin Gerin - Insulated Case
MP63H-3P-6000A-EO-DO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 6300A frame, includes 6300A sensor rating with 6000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
XT2LQ3100LFF000XXX
XT2LQ3100LFF000XXX
ABB - Molded Case
XT2LQ3100LFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 3-Pole, 100A, 600V, 35kA@600V, Ekip M-LIU (Electronic Motor Protector with integrated overload and phase loss detection), UL 100% Rated, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No - 1SDA07211R1 global reference
From Get Price
Limited Stock
MP32-3P-3000A-EO-DO-LS
MP32-3P-3000A-EO-DO-LS
Merlin Gerin - Insulated Case
MP32-3P-3000A-EO-DO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3200A frame includes 3000A, 3200A sensor rating with 3000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
M4SRG0400
M4SRG0400
Cutler Hammer - Rating Plug
M4SRG0400, Cutler Hammer, Magnum DS, rating plug, field installable kit for changing the sensor/rating plug rating on fixed or drawout circuit breakers, includes 1 rating plug plus 4 sensors for 4 pole breakers, rated for 400A, suitable for use with standard frame MDS air circuit breaker frame types, for use with Digitrip 220,520,520M,520MC,1150 solid state programmers
From Get Price
In Stock
HMA2200T
HMA2200T
Westinghouse - Trip Units And Programmers
HMA2200T, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 200A, suitable for 800A- MA,HMA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From $1,309.72
Limited Stock
8539SHA56V04H10
8539SHA56V04H10
Square D - Motor Starter
8539SHA56V04H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD MAL36600-44M circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 200 HP @ 240V, complete with 277V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price
Limited Stock
8539SBA43V01
8539SBA43V01
Square D - Motor Starter
8539SBA43V01, Square D, Class 8539, combination non-reversing motor starter, NEMA size , requires 3 thermal units, supplied with MAG-GARD GJL36015-M03 circuit breaker and NEMA type 12/3R without external reset enclosure, 3P, 3PH, 600V, 1 1/2-3 HP @ 240V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems
From Get Price
Limited Stock
MP12-3P-1200A-EO-BO-LSI
MP12-3P-1200A-EO-BO-LSI
Merlin Gerin - Insulated Case
MP12-3P-1200A-EO-BO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1200A frame with 1200A sensor rating with 1200A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP32-3P-3200A-EO-BO-LS
MP32-3P-3200A-EO-BO-LS
Merlin Gerin - Insulated Case
MP32-3P-3200A-EO-BO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3200A frame includes 3200A sensor rating with 3200A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
8539SEA42V06H10
8539SEA42V06H10
Square D - Motor Starter
8539SEA42V06H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 3, requires 3 thermal units, supplied with MAG-GARD FAL36100-18M circuit breaker and NEMA type 12/3R without external reset enclosure, 3P, 3PH, 600V, 30-50 HP @ 480V, complete with 480V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price
Limited Stock
AKR-10AE-50-MO-DO-LI
AKR-10AE-50-MO-DO-LI
General Electric - Air
AKR-10AE-50-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with MicroVersa Trip Plus - Gen 2 Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
Limited Stock
MP63H2-3P-6000A-EO-DO-LS
MP63H2-3P-6000A-EO-DO-LS
Merlin Gerin - Insulated Case
MP63H2-3P-6000A-EO-DO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 6300A frame, includes 6300A sensor rating with 6000A rating plug, 3P, 3PH, 600V, 125kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP63-3P-6000A-EO-BO-LI
MP63-3P-6000A-EO-BO-LI
Merlin Gerin - Insulated Case
MP63-3P-6000A-EO-BO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 6300A frame includes 6300A sensor rating with 6000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price