LA2200T
Westinghouse - Trip Units And Programmers
LA2200T, Westinghouse, LA Series, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 200A, suitable for 400A- LA,HLA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From $437.92

PAF210000TM
Westinghouse - Trip Units And Programmers
PAF210000TM, Westinghouse, PAF Series, type , interchangeable trip unit with I - Instantaneous trip functions, front adjustable, front connected, rated for 2000A, suitable for PBF,PAF 2000A molded case circuit breaker frame types, magnetic trip range 3500-10000A, Magnetic Only trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

PB35000TM
Westinghouse - Trip Units And Programmers
PB35000TM, Westinghouse, Cutler Hammer, Eaton, PB Series, type , interchangeable trip unit with I - Instantaneous trip functions, front adjustable, rear connected, rated for 2000A, suitable for PB,PA 2500A molded case circuit breaker frame types, magnetic trip range 1500-5000A, Magnetic Only trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

MP08-3P-125A-EO-DO-LSIG
Merlin Gerin - Insulated Case
MP08-3P-125A-EO-DO-LSIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 800A frame with 250A trip and 125A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

CR306EXK023
General Electric - Motor Starter
CR306EXK023, General Electric, 300 Line, type , 3P, 3PH, 90A, 600V, 25 hp, complete with 200V-208V 50/60Hz, AC coil, non-reversing, non-combination open type magnetic starter, NEMA size 3, equipped with overload rely to provide 17.0-35.0A with 125 max fuse rating, 125 max breaker rating, suitable for use with CR306 motor control systems
From Get Price

MP16H2-3P-1600A-MO-BO-LSG
Merlin Gerin - Insulated Case
MP16H2-3P-1600A-MO-BO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1600A frame, includes 1600A sensor rating with 1600A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

8539SHW46V03H30
Square D - Motor Starter
8539SHW46V03H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD MAL36600-44M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 200 HP @ 240V, complete with 240V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price

MP63H-3P-6000A-EO-BO-LSIG
Merlin Gerin - Insulated Case
MP63H-3P-6000A-EO-BO-LSIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 6300A frame, includes 6300A sensor rating with 6000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

8539SBR43V08
Square D - Motor Starter
8539SBR43V08, Square D, Class 8539, combination non-reversing motor starter, NEMA size 00, requires 3 thermal units, supplied with MAG-GARD GJL36015-M03 circuit breaker and NEMA type 7 & 9 spin top type enclosure, 3P, 3PH, 600V, 1 1/2-3 HP @ 208V, complete with 208V coil, suitable for use with Class 8539 motor control systems
From Get Price

ECN2408CAD
Cutler Hammer - Motor Starter
ECN2408CAD, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP and CPT (control power transformers), type , 3P, 3PH, 5 HP @ 460V, 600V, complete with 480V coil, NEMA size , 15A HMCP circuit breaker enclosed in NEMA Type 12 dust-tight industrial enclosure with external reset, suitable for use with Freedom Series motor control systems
From Get Price

XT4HQ3060LFF000XXX
ABB - Molded Case
XT4HQ3060LFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 3-Pole, 60A, 600V, 25kA@600V, Ekip M-LIU (Electronic Motor Protector with integrated overload and phase loss detection), UL 100% Rated, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No - 1SDA07211R1 global reference
From Get Price

MP12H2-3P-1200A-EO-BO-LS
Merlin Gerin - Insulated Case
MP12H2-3P-1200A-EO-BO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1200A frame, includes 1200A sensor rating with 1200A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

AKRT-7B-50-MO-DO-LI
General Electric - Air
AKRT-7B-50-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 2000A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with MicroVersa Trip RMS-9 Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

8539SHW46V01H20
Square D - Motor Starter
8539SHW46V01H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD MAL36600-44M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 200 HP @ 240V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price

PLA36120U64AE1AB
Square D - Molded Case
PLA36120U64AE1AB, Schneider Electric, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 1200A, 600V, 100kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, complete with 2A/2B auxiliary switch, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breaker
From Get Price

AM-13.8-750-VHK-R-2000A
ABB - Vacuum Circuit Breaker
AM-13.8-750-VHK-R-2000A, ABB, AM-VHK-R Series, , 3PH, 3P, 15000 VAC, 2000 Frame, Electrically Operated, Draw-Out, Medium Voltage vacuum circuit breaker Retrofit, Retrofitted for AM-13.8-750, For Use In M-36H Switchgear. Operating Voltage, Control Voltages, Wiring, and Additional Accessories to be determined before ordering.
From Get Price

HLB3400TV
Westinghouse - Trip Units And Programmers
HLB3400TV, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 400A, 50°C, suitable for 400A- LB,HLB standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price

MP25-3P-2500A-MO-BO-LSG
Merlin Gerin - Insulated Case
MP25-3P-2500A-MO-BO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2500A frame includes 2500A sensor rating with 2500A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

AKR-9A-30-MO-DO-LI
General Electric - Air
AKR-9A-30-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with MicroVersa Trip Plus - Gen1 Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

MP63H2-3P-6300A-MO-DO-LIG
Merlin Gerin - Insulated Case
MP63H2-3P-6300A-MO-DO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 6300A frame, includes 6300A sensor rating with 6300A rating plug, 3P, 3PH, 600V, 125kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

8539SGA54V01H20
Square D - Motor Starter
8539SGA54V01H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 5, requires 3 thermal units, supplied with MAG-GARD LAL36400-32M circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 75 HP @ 240V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price

HLB2250TA
Westinghouse - Trip Units And Programmers
HLB2250TA, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 250A, 50°C, suitable for 400A- LB,HLB standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price

MP63-3P-6300A-MO-BO-LIG
Merlin Gerin - Insulated Case
MP63-3P-6300A-MO-BO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 6300A frame includes 6300A sensor rating with 6300A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

AM-13.8-1000-VHK-R-1200A
ABB - Vacuum Circuit Breaker
AM-13.8-1000-VHK-R-1200A, ABB, AM-VHK-R Series, , 3PH, 3P, 15000 VAC, 1200 Frame, Electrically Operated, Draw-Out, Medium Voltage vacuum circuit breaker Retrofit, Retrofitted for AM-13.8-1000, For Use In M-36H Switchgear. Operating Voltage, Control Voltages, Wiring, and Additional Accessories to be determined before ordering.
From Get Price