1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
PA37000TM
PA37000TM
Westinghouse - Trip Units And Programmers
PA37000TM, Westinghouse, PA Series, type , interchangeable trip unit with I - Instantaneous trip functions, front adjustable, rear connected, rated for 2000A, suitable for PB,PA 2500A molded case circuit breaker frame types, magnetic trip range 2500-7000A, Magnetic Only trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
Limited Stock
MP20-3P-1200A
MP20-3P-1200A
Merlin Gerin - Insulated Case
MP20-3P-1200A, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2000A frame includes 1200A, 1600A or 2000A sensor rating with 1200A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
8539SJA53V06H20
8539SJA53V06H20
Square D - Motor Starter
8539SJA53V06H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 7, requires 3 thermal units, supplied with MAG-GARD MAL361000-47M circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 600 HP @ 480V, complete with 480V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price
Limited Stock
CR306CXF003
CR306CXF003
General Electric - Motor Starter
CR306CXF003, General Electric, 300 Line, type , 3P, 3PH, 27A, 600V, 7.5 hp, complete with 230V-240V 50/60Hz, AC coil, non-reversing, non-combination open type magnetic starter, NEMA size 00-1, equipped with overload rely to provide 3.2-6.8A with 25 max fuse rating, 25 max breaker rating, suitable for use with CR306 motor control systems
From Get Price
Limited Stock
MP40-3P-4000A-EO-DO-LS
MP40-3P-4000A-EO-DO-LS
Merlin Gerin - Insulated Case
MP40-3P-4000A-EO-DO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 4000A frame includes 4000A sensor rating with 4000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
HLA3200TV
HLA3200TV
Westinghouse - Trip Units And Programmers
HLA3200TV, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 200A, 50°C, suitable for 400A- LA,HLA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price
Limited Stock
MP63-3P-6300A-MO-BO-LSIG
MP63-3P-6300A-MO-BO-LSIG
Merlin Gerin - Insulated Case
MP63-3P-6300A-MO-BO-LSIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 6300A frame includes 6300A sensor rating with 6300A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
ECN2218BAD-E3R5
ECN2218BAD-E3R5
Cutler Hammer - Motor Starter
ECN2218BAD-E3R5, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP, type , 3P, 3PH, 2 HP @ 230V, 600V, complete with 240V coil, NEMA size 1, 15A HMCP circuit breaker enclosed in oversize NEMA Type 12 dust-tight industrial enclosure with internal reset, without control transformer, suitable for use with Freedom Series motor control systems
From Get Price
Limited Stock
TQC1125WL
TQC1125WL
General Electric - Molded Case
TQC1125WL, General Electric, Q-Line, type , 1P, 1PH, 120/240V, 25A, 5kA@120V, UL listed, standard interrupting capacity, Feed-Thru, LI - Long-Time and Instantaneous trip functions, line & load side lug terminals, for use with PowerMark circuit breaker load centers, Thermal Magnetic molded case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
MP30-3P-3000A-MO-BO-LSI
MP30-3P-3000A-MO-BO-LSI
Merlin Gerin - Insulated Case
MP30-3P-3000A-MO-BO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3000A frame includes 3000A sensor rating with 3000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
ECN2418DA6
ECN2418DA6
Cutler Hammer - Motor Starter
ECN2418DA6, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP and CPT (control power transformers), type , 3P, 3PH, 3 HP @ 575V, 600V, complete with 600V coil, NEMA size 1, 7A HMCP circuit breaker enclosed in NEMA Type 12 dust-tight industrial enclosure with external reset, suitable for use with Freedom Series motor control systems
From Get Price
Limited Stock
M4NRG0250
M4NRG0250
Cutler Hammer - Rating Plug
M4NRG0250, Cutler Hammer, Magnum DS, rating plug, field installable kit for changing the sensor/rating plug rating on fixed or drawout circuit breakers, includes 1 rating plug plus 4 sensors for 4 pole breakers, rated for 250A, suitable for use with narrow frame MDN air circuit breaker frame types, for use with Digitrip 220,520,520M,520MC,1150 solid state programmers
From Get Price
Limited Stock
8539SDG43V06H30
8539SDG43V06H30
Square D - Motor Starter
8539SDG43V06H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 2, requires 3 thermal units, supplied with MAG-GARD GJL36050-M05 circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 20-25 HP @ 480V, complete with 480V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price
Limited Stock
8539SDW43V08H20
8539SDW43V08H20
Square D - Motor Starter
8539SDW43V08H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 2, requires 3 thermal units, supplied with MAG-GARD GJL36050-M05 circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 7 1/2-10 HP @ 208V, complete with 208V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price
Limited Stock
TEPHM4
TEPHM4
General Electric - Part And Accessory
TEPHM4, General Electric, TDM Model, circuit breaker accessory, Operating Handles, rotary level handle mechanism, handle included, door-mounted, handle mounting location right, handle to device connection 5-1/8 inch to 5-13/16 inch adjustable depth shaft, NEMA 1/3R/12, suitable for use with TEB,TEC,TB1,TED,THED type molded case circuit breakers
From Get Price
Limited Stock
HMA2200TV
HMA2200TV
Westinghouse - Trip Units And Programmers
HMA2200TV, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 200A, 50°C, suitable for 800A- MA,HMA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
Limited Stock
THQL11W15
THQL11W15
General Electric - Molded Case
THQL11W15, General Electric, Q-Line, type , 1P, 1PH, 120/240V, 15A, 10kA@120V/240V, common trip, UL listed, high interrupting capacity, Plug-In, LI - Long-Time and Instantaneous trip functions, load side lug terminals, for use with PowerMark circuit breaker load centers, Thermal Magnetic, molded case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
8539SBW43V08H10
8539SBW43V08H10
Square D - Motor Starter
8539SBW43V08H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size , requires 3 thermal units, supplied with MAG-GARD GJL36015-M03 circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 1 1/2-3 HP @ 208V, complete with 208V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price
Limited Stock
MP08H-3P-800A
MP08H-3P-800A
Merlin Gerin - Insulated Case
MP08H-3P-800A, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 800A frame, includes 800A sensor rating with 800A rating plug, 3P, 3PH, 600V, 65kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP trip units, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP25-3P-2500A-EO-BO-LI
MP25-3P-2500A-EO-BO-LI
Merlin Gerin - Insulated Case
MP25-3P-2500A-EO-BO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2500A frame includes 2500A sensor rating with 2500A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
In Stock
S131G
S131G
Schneider Electric - Trip Units And Programmers
S131G, Square D, Schneider Electric, Merlin Gerin, Micrologic, field installable Micrologic standard 3.0 trip unit with LI - Long-Time and Instantaneous trip functions, with type 'G' rating plug, suitable for NS,NT,NW,PG,PJ,PK,PL,RG,RJ,RK,RL molded case & insulated case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From $778.04
Limited Stock
PA11121
PA11121
Square D - Under Voltage Release
PA11121, Square D, Square D Series, type , under voltage release, 120V, (1) undervoltage trip, when installed in a circuit breaker the part number suffix is -1121, suitable for use with PA,PAF,PAL,PAP,PH,PHF,PHL,PHP,PC,PCF,PCL,PCP,PE,PEF,PEL,PEP,PX,PXF,PXL,PXP frame molded case circuit breakers
From Get Price
Limited Stock
MP20-3P-2000A-EO-BO-LI
MP20-3P-2000A-EO-BO-LI
Merlin Gerin - Insulated Case
MP20-3P-2000A-EO-BO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2000A frame includes 2000A sensor rating with 2000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
8539SDG42V01H10
8539SDG42V01H10
Square D - Motor Starter
8539SDG42V01H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 2, requires 3 thermal units, supplied with MAG-GARD GJL36030-M04 circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 5- 7 1/2 HP @ 240V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price