1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
MA2350TV
MA2350TV
Westinghouse - Trip Units And Programmers
MA2350TV, Westinghouse, MA Series, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 350A, 50°C, suitable for 800A- MA,HMA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
Limited Stock
M4NRG1250
M4NRG1250
Cutler Hammer - Rating Plug
M4NRG1250, Cutler Hammer, Magnum DS, rating plug, field installable kit for changing the sensor/rating plug rating on fixed or drawout circuit breakers, includes 1 rating plug plus 4 sensors for 4 pole breakers, rated for 1250A, suitable for use with narrow frame MDN air circuit breaker frame types, for use with Digitrip 220,520,520M,520MC,1150 solid state programmers
From Get Price
Limited Stock
MP20H2-3P-2000A-MO-DO-LS
MP20H2-3P-2000A-MO-DO-LS
Merlin Gerin - Insulated Case
MP20H2-3P-2000A-MO-DO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2000A frame, includes 2000A sensor rating with 2000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
8539SHA43V08H30
8539SHA43V08H30
Square D - Motor Starter
8539SHA43V08H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD LAL36400-36M circuit breaker and NEMA type 12/3R without external reset enclosure, 3P, 3PH, 600V, 100 HP @ 208V, complete with 208V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price
Limited Stock
HLA2250TV
HLA2250TV
Westinghouse - Trip Units And Programmers
HLA2250TV, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 250A, 50°C, suitable for 400A- LA,HLA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price
Limited Stock
ECN2204CAC-E3
ECN2204CAC-E3
Cutler Hammer - Motor Starter
ECN2204CAC-E3, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP, type , 3P, 3PH, 2 HP @ 460V, 600V, complete with 480V coil, NEMA size , 7A HMCP circuit breaker enclosed in oversize NEMA Type 4X 304-grade watertight & dust-tight stainless steel enclosure without control transformer, suitable for use with Freedom Series motor control systems
From Get Price
Limited Stock
KA2090TA
KA2090TA
Westinghouse - Trip Units And Programmers
KA2090TA, Westinghouse, KA Series, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 90A, 50°C, suitable for 225A- KA,HKA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
Limited Stock
8539SFW44V01H20
8539SFW44V01H20
Square D - Motor Starter
8539SFW44V01H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 4, requires 3 thermal units, supplied with MAG-GARD KAL36250-29M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 50 HP @ 240V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price
Limited Stock
HLA3225TA
HLA3225TA
Westinghouse - Trip Units And Programmers
HLA3225TA, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 225A, 50°C, suitable for 400A- LA,HLA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price
Limited Stock
CED3K
CED3K
Challenger - Mounting Hardware
CED3K, PCS direct replacement mounting hardware for Challenger PM3a bolt-on style panel boards, rated for 225A 600V max, Copper, Dual/Twin Branch mounting style, suitable for use with CE,CF,CFS,CFH,ED,EDB,EDH,EHD,FD,FDB,FDC,HFD,HMCP,E2F,FWF circuit breaker frames, complete with all associated hardware, screws and cover plates
From Get Price
Limited Stock
8539SCT8V07
8539SCT8V07
Square D - Motor Starter
8539SCT8V07, Square D, Class 8539, combination non-reversing motor starter, NEMA size 00, requires 3 thermal units, supplied with 15A type FAL thermal magnetic circuit breaker and NEMA type 7 & 9 bolted type type enclosure, 3P, 3PH, 600V, 7 1/2 HP @ 600V, complete with 600V coil, suitable for use with Class 8539 motor control systems
From Get Price
Limited Stock
8539SDW43V02H10
8539SDW43V02H10
Square D - Motor Starter
8539SDW43V02H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 2, requires 3 thermal units, supplied with MAG-GARD GJL36050-M05 circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 10 HP @ 240V, complete with 120V 60Hz/110V 50Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price
Limited Stock
TR40S2500
TR40S2500
General Electric - Rating Plug
TR40S2500, General Electric, Power Break I, type , rating plug element, rated for 2500A, 4000A sensor rating, suitable for use with 4000A - TP,TC,THP,THC,AKR100 draw-out style only, insulated case and low voltage power air circuit breaker frame types, for use with MicroVersaTrip RMS-9,MicroVersaTrip Plus,MicroVersaTrip PM trip units & circuit breakers
From Get Price
Limited Stock
MP63H-3P-6000A-EO-DO-LSG
MP63H-3P-6000A-EO-DO-LSG
Merlin Gerin - Insulated Case
MP63H-3P-6000A-EO-DO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 6300A frame, includes 6300A sensor rating with 6000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
PLA36040U64AE1AB
PLA36040U64AE1AB
Square D - Molded Case
PLA36040U64AE1AB, Schneider Electric, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 400A, 600V, 100kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, complete with 2A/2B auxiliary switch, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breaker
From Get Price
Limited Stock
8539SCA44V01
8539SCA44V01
Square D - Motor Starter
8539SCA44V01, Square D, Class 8539, combination non-reversing motor starter, NEMA size 1, requires 3 thermal units, supplied with MAG-GARD GJL36030-M04 circuit breaker and NEMA type 12/3R without external reset enclosure, 3P, 3PH, 600V, 5-71/2 HP @ 240V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems
From Get Price
Limited Stock
8539SCA54V06H20
8539SCA54V06H20
Square D - Motor Starter
8539SCA54V06H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 1, requires 3 thermal units, supplied with MAG-GARD GJL36030-M04 circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 10 HP @ 480V, complete with 480V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price
Limited Stock
8539SJA53V04H10
8539SJA53V04H10
Square D - Motor Starter
8539SJA53V04H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 7, requires 3 thermal units, supplied with MAG-GARD MAL361000-47M circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 300 HP @ 240V, complete with 277V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price
Limited Stock
8539SDW53V08H10
8539SDW53V08H10
Square D - Motor Starter
8539SDW53V08H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 2, requires 3 thermal units, supplied with MAG-GARD GJL36050-M05 circuit breaker and NEMA type 4X enclosure, 3P, 3PH, 600V, 7 1/2-10 HP @ 208V, complete with 208V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price
Limited Stock
ECN2438EAG
ECN2438EAG
Cutler Hammer - Motor Starter
ECN2438EAG, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP and CPT (control power transformers), type , 3P, 3PH, 20 HP @ 200V, 600V, complete with 208V coil, NEMA size 3, 100A HMCP circuit breaker enclosed in NEMA Type 12 dust-tight industrial enclosure with external reset, suitable for use with Freedom Series motor control systems
From Get Price
Limited Stock
8539SCW55V06H10
8539SCW55V06H10
Square D - Motor Starter
8539SCW55V06H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 1, requires 3 thermal units, supplied with MAG-GARD GJL36050-M05 circuit breaker and NEMA type 4X enclosure, 3P, 3PH, 600V, 7 1/2 HP @ 208V, complete with 480V 60Hz/440V 50Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price
In Stock
HLA3090T
HLA3090T
Westinghouse - Trip Units And Programmers
HLA3090T, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 90A, suitable for 400A- LA,HLA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From $676.24
Limited Stock
HLA2300TA
HLA2300TA
Westinghouse - Trip Units And Programmers
HLA2300TA, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 300A, 50°C, suitable for 400A- LA,HLA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price
Limited Stock
M3RRG4000
M3RRG4000
Cutler Hammer - Rating Plug
M3RRG4000, Cutler Hammer, Magnum DS, rating plug, field installable kit for changing the sensor/rating plug rating on fixed or drawout circuit breakers, includes 1 rating plug plus 6 sensors for 3 pole breakers, rated for 4000A, suitable for use with double frame MDS air circuit breaker frame types, for use with Digitrip 220,520,520M,520MC,1150 solid state programmers
From Get Price