MP16H-3P-1600A-MO-DO-LSI
Merlin Gerin - Insulated Case
MP16H-3P-1600A-MO-DO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1600A frame, includes 1600A sensor rating and 1600A rating plug, 3P, 3PH, 600V, 65kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

HLA2150T
Westinghouse - Trip Units And Programmers
HLA2150T, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 150A, suitable for 400A- LA,HLA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From $715.74

8539SEW42V07H20
Square D - Motor Starter
8539SEW42V07H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 3, requires 3 thermal units, supplied with MAG-GARD FAL36100-18M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 40-50 HP @ 600V, complete with 600V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price

8539SHA45V06H10
Square D - Motor Starter
8539SHA45V06H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD MAL36600-42M circuit breaker and NEMA type 12/3R without external reset enclosure, 3P, 3PH, 600V, 350 HP @ 480V, complete with 480V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price

ECN2414DA7
Cutler Hammer - Motor Starter
ECN2414DA7, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP and CPT (control power transformers), type , 3P, 3PH, 5 HP @ 575V, 600V, complete with 600V coil, NEMA size 1, 15A HMCP circuit breaker enclosed in NEMA Type 4X 304-grade watertight & dust-tight stainless steel enclosure, suitable for use with Freedom Series motor control systems
From Get Price

8539SHW43V01H10
Square D - Motor Starter
8539SHW43V01H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD LAL36400-36M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 250 HP @ 480V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price

8539SEG42V07H30
Square D - Motor Starter
8539SEG42V07H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 3, requires 3 thermal units, supplied with MAG-GARD FAL36100-18M circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 40-50 HP @ 600V, complete with 600V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price

8539SHA43V06H10
Square D - Motor Starter
8539SHA43V06H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD LAL36400-36M circuit breaker and NEMA type 12/3R without external reset enclosure, 3P, 3PH, 600V, 250 HP @ 480V, complete with 480V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price

ECN2404DA7
Cutler Hammer - Motor Starter
ECN2404DA7, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP and CPT (control power transformers), type , 3P, 3PH, 5 HP @ 575V, 600V, complete with 600V coil, NEMA size , 15A HMCP circuit breaker enclosed in NEMA Type 4X 304-grade watertight & dust-tight stainless steel enclosure, suitable for use with Freedom Series motor control systems
From Get Price

8539SHA45V04H20
Square D - Motor Starter
8539SHA45V04H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD MAL36600-42M circuit breaker and NEMA type 12/3R without external reset enclosure, 3P, 3PH, 600V, 350 HP @ 480V, complete with 277V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price

MP30H-3P-3000A-EO-DO-LSG
Merlin Gerin - Insulated Case
MP30H-3P-3000A-EO-DO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3000A frame, includes 3000A sensor rating with 3000A rating plug, 3P, 3PH, 600V, 75kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

HKA2100TA
Westinghouse - Trip Units And Programmers
HKA2100TA, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 100A, 50°C, suitable for 225A- KA,HKA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

MP40H-3P-4000A-MO-BO-LSG
Merlin Gerin - Insulated Case
MP40H-3P-4000A-MO-BO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 4000A frame, includes 4000A sensor rating with 4000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP20H-3P-1000A
Merlin Gerin - Insulated Case
MP20H-3P-1000A, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2000A frame, includes 1200A, 1600A or 2000A sensor rating with 1000A rating plug, 3P, 3PH, 600V, 75kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

8539SDA52V08H30
Square D - Motor Starter
8539SDA52V08H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 2, requires 3 thermal units, supplied with MAG-GARD GJL36030-M04 circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 5 HP @ 208V, complete with 208V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price

HKB2200TA
Westinghouse - Trip Units And Programmers
HKB2200TA, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 200A, 50°C, suitable for 250A- KB,HKB standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price

AKR-10C-100-MO-DO-LI
General Electric - Air
AKR-10C-100-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 4000A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with MicroVersa Trip Plus - Gen 2 Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

MP30H2-3P-3000A-EO-BO-LSG
Merlin Gerin - Insulated Case
MP30H2-3P-3000A-EO-BO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3000A frame, includes 3000A sensor rating with 3000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

8539SCW54V03H20
Square D - Motor Starter
8539SCW54V03H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 1, requires 3 thermal units, supplied with MAG-GARD GJL36030-M04 circuit breaker and NEMA type 4X enclosure, 3P, 3PH, 600V, 5-7 1/2 HP @ 240V, complete with 240V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price

M3NRG1250
Cutler Hammer - Rating Plug
M3NRG1250, Cutler Hammer, Magnum DS, rating plug, field installable kit for changing the sensor/rating plug rating on fixed or drawout circuit breakers, includes 1 rating plug plus 3 sensors for 3 pole breakers, rated for 1250A, suitable for use with narrow frame MDN air circuit breaker frame types, for use with Digitrip 220,520,520M,520MC,1150 solid state programmers
From Get Price

8539SCW45V08H20
Square D - Motor Starter
8539SCW45V08H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 1, requires 3 thermal units, supplied with MAG-GARD GJL36050-M05 circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 7 1/2 HP @ 208V, complete with 208V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price

PAF26000TM
Westinghouse - Trip Units And Programmers
PAF26000TM, Westinghouse, PAF Series, type , interchangeable trip unit with I - Instantaneous trip functions, front adjustable, front connected, rated for 2000A, suitable for PBF,PAF 2000A molded case circuit breaker frame types, magnetic trip range 2000-6000A, Magnetic Only trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

MP40H-3P-4000A-EO-DO-LI
Merlin Gerin - Insulated Case
MP40H-3P-4000A-EO-DO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 4000A frame, includes 4000A sensor rating with 4000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

TQP235CL
General Electric - Molded Case
TQP235CL, General Electric, PowerMark, type , 2P, 1PH, 120/240V, 35A, 5kA@240V, UL listed, standard interrupting capacity, enclosure compensated, Plug-In, LI - Long-Time and Instantaneous trip functions, copper load side lug terminals, for use with PowerMark circuit breaker load centers, Thermal Magnetic molded case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price