1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
AKRT-7AE-50-MO-DO-LI
AKRT-7AE-50-MO-DO-LI
General Electric - Air
AKRT-7AE-50-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 2000A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with MicroVersa Trip RMS-9 Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
Limited Stock
MP08H-3P-300A
MP08H-3P-300A
Merlin Gerin - Insulated Case
MP08H-3P-300A, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 800A frame with 400A or 600A sensor rating and 300A rating plug, 3P, 3PH, 600V, 65kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
8539SDR41V06
8539SDR41V06
Square D - Motor Starter
8539SDR41V06, Square D, Class 8539, combination non-reversing motor starter, NEMA size 00, requires 3 thermal units, supplied with MAG-GARD GJL36015-M03 circuit breaker and NEMA types 7 & 9 spin top type enclosure, 3P, 3PH, 600V, 5-7 1/2 HP @ 480V, complete with 480V coil, suitable for use with Class 8539 motor control systems
From Get Price
Limited Stock
MP08-3P-150A-MO-DO-LSIG
MP08-3P-150A-MO-DO-LSIG
Merlin Gerin - Insulated Case
MP08-3P-150A-MO-DO-LSIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 800A frame with 250A trip and 150A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
XT4XQ3060LFF000XXX
XT4XQ3060LFF000XXX
ABB - Molded Case
XT4XQ3060LFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 3-Pole, 60A, 600V, 100kA@600V, Ekip M-LIU (Electronic Motor Protector with integrated overload and phase loss detection), UL 100% Rated, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No - 1SDA07211R1 global reference
From Get Price
Limited Stock
MP32H-3P-3200A-EO-DO-LSI
MP32H-3P-3200A-EO-DO-LSI
Merlin Gerin - Insulated Case
MP32H-3P-3200A-EO-DO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3200A frame, includes 3200A sensor rating with 3200A rating plug, 3P, 3PH, 600V, 75kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
8539SHW45V01H20
8539SHW45V01H20
Square D - Motor Starter
8539SHW45V01H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD MAL36600-42M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 150 HP @ 208V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price
Limited Stock
MA3175TV
MA3175TV
Westinghouse - Trip Units And Programmers
MA3175TV, Westinghouse, MA Series, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 175A, 50°C, suitable for 800A- MA,HMA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
Limited Stock
8539SBW53V04H20
8539SBW53V04H20
Square D - Motor Starter
8539SBW53V04H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size , requires 3 thermal units, supplied with MAG-GARD GJL36015-M03 circuit breaker and NEMA type 4X enclosure, 3P, 3PH, 600V, 1 1/2-3 HP @ 240V, complete with 277V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price
Limited Stock
8539SHA43V07H20
8539SHA43V07H20
Square D - Motor Starter
8539SHA43V07H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD LAL36400-36M circuit breaker and NEMA type 12/3R without external reset enclosure, 3P, 3PH, 600V, 300 HP @ 600V, complete with 600V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price
Limited Stock
8539SCW44V06H30
8539SCW44V06H30
Square D - Motor Starter
8539SCW44V06H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 1, requires 3 thermal units, supplied with MAG-GARD GJL36030-M04 circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 10 HP @ 480V, complete with 480V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price
Limited Stock
MP50-3P-3200A
MP50-3P-3200A
Merlin Gerin - Insulated Case
MP50-3P-3200A, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 5000A frame includes 3200A, 4000A or 5000A sensor rating with 3200A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
XT4XU3060LFF000XXX
XT4XU3060LFF000XXX
ABB - Molded Case
XT4XU3060LFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 3-Pole, 60A, 600V, 100kA@600V, Ekip M-LIU (Electronic Motor Protector with integrated overload and phase loss detection), UL Standard, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No - 1SDA07211R1 global reference
From Get Price
Limited Stock
XT4VU3040LFF000XXX
XT4VU3040LFF000XXX
ABB - Molded Case
XT4VU3040LFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 3-Pole, 40A, 600V, 65kA@600V, Ekip M-LIU (Electronic Motor Protector with integrated overload and phase loss detection), UL Standard, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No - 1SDA07211R1 global reference
From Get Price
In Stock
HLA2175T
HLA2175T
Westinghouse - Trip Units And Programmers
HLA2175T, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 175A, suitable for 400A- LA,HLA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From $570.96
In Stock
S141D
S141D
Merlin Gerin - Trip Units And Programmers
S141D, Square D, Schneider Electric, Merlin Gerin, Micrologic, field installable Micrologic standard 3.0A trip unit with LI - Long-Time and Instantaneous trip functions and ammeter, with type 'D' rating plug, suitable for NS,NT,NW,PG,PJ,PK,PL,RG,RJ,RK,RL molded case & insulated case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From $1,651.56
Limited Stock
TQC2140WL
TQC2140WL
General Electric - Molded Case
TQC2140WL, General Electric, Q-Line, type , 2P, 1PH, 120/240V, 40A, 5kA@240V, UL listed, standard interrupting capacity, Feed-Thru, LI - Long-Time and Instantaneous trip functions, line & load side lug terminals, for use with PowerMark circuit breaker load centers, Thermal Magnetic molded case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
PBF28000TM
PBF28000TM
Westinghouse - Trip Units And Programmers
PBF28000TM, Westinghouse, PBF Series, type , interchangeable trip unit with I - Instantaneous trip functions, front adjustable, front connected, rated for 2000A, suitable for PBF,PAF 2000A molded case circuit breaker frame types, magnetic trip range 3500-8000A, Magnetic Only trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
Limited Stock
MP12H-3P-1000A-MO-BO-LI
MP12H-3P-1000A-MO-BO-LI
Merlin Gerin - Insulated Case
MP12H-3P-1000A-MO-BO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1200A frame with 1200A sensor rating with 1000A rating plug, 3P, 3PH, 600V, 65kA@480V, acceptable with the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP50H2-3P-5000A-EO-BO-LIG
MP50H2-3P-5000A-EO-BO-LIG
Merlin Gerin - Insulated Case
MP50H2-3P-5000A-EO-BO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 5000A frame, includes 5000A sensor rating with 5000A rating plug, 3P, 3PH, 600V, 125kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP50H-3P-5000A-MO-DO-LIG
MP50H-3P-5000A-MO-DO-LIG
Merlin Gerin - Insulated Case
MP50H-3P-5000A-MO-DO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 5000A frame, includes 5000A sensor rating with 5000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP32H2-3P-3200A-MO-DO-LSI
MP32H2-3P-3200A-MO-DO-LSI
Merlin Gerin - Insulated Case
MP32H2-3P-3200A-MO-DO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3200A frame, includes 3200A sensor rating with 3200A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
HKB3090TA
HKB3090TA
Westinghouse - Trip Units And Programmers
HKB3090TA, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 90A, 50°C, suitable for 250A- KB,HKB standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price
Limited Stock
MP50H-3P-5000A-MO-DO-LI
MP50H-3P-5000A-MO-DO-LI
Merlin Gerin - Insulated Case
MP50H-3P-5000A-MO-DO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 5000A frame, includes 5000A sensor rating with 5000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price