1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
MP12H-3P-1000A-MO-BO-LS
MP12H-3P-1000A-MO-BO-LS
Merlin Gerin - Insulated Case
MP12H-3P-1000A-MO-BO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1200A frame with 1200A sensor rating with 1000A rating plug, 3P, 3PH, 600V, 65kA@480V, acceptable with the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
In Stock
KB2090T
KB2090T
Westinghouse - Trip Units And Programmers
KB2090T, Westinghouse, AB DE-ION, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 90A, suitable for 250A- KB,HKB standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From $359.44
Limited Stock
PJA36060U64AE1RE10
PJA36060U64AE1RE10
Square D - Molded Case
PJA36060U64AE1RE10, Square D, Schneider Electric, PowerPact, type , 3P, ABC phase connection, 3PH, 600A, 600V, 65kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, complete with door mounted standard black handle, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breaker
From Get Price
Limited Stock
8539SHA46V01H10
8539SHA46V01H10
Square D - Motor Starter
8539SHA46V01H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD MAL36600-44M circuit breaker and NEMA type 12/3R without external reset enclosure, 3P, 3PH, 600V, 200 HP @ 240V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price
Limited Stock
LA3450TV
LA3450TV
Westinghouse - Trip Units And Programmers
LA3450TV, Westinghouse, LA Series, type , interchangeable trip unit with LI - Long Time and Instantaneous trip functions, rated for 450A, 50°C, suitable for 400A- LA,HLA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price
Limited Stock
PAF212000TM
PAF212000TM
Westinghouse - Trip Units And Programmers
PAF212000TM, Westinghouse, PAF Series, type , interchangeable trip unit with I - Instantaneous trip functions, front adjustable, front connected, rated for 2000A, suitable for PBF,PAF 2000A molded case circuit breaker frame types, magnetic trip range 4000-12000A, Magnetic Only trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
Limited Stock
MP32-3P-3000A-EO-BO-LSI
MP32-3P-3000A-EO-BO-LSI
Merlin Gerin - Insulated Case
MP32-3P-3000A-EO-BO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3200A frame includes 3000A, 3200A sensor rating with 3000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
150-DH-1000E-FG-R-3000A
150-DH-1000E-FG-R-3000A
Merlin Gerin - Vacuum Circuit Breaker
150-DH-1000E-FG-R-3000A, Merlin Gerin, DH-FG-R Series, , 3PH, 3P, 15000 VAC, 3000 Frame, Electrically Operated, Draw-Out, Medium Voltage vacuum circuit breaker Retrofit, Retrofitted for 150-DH-1000, For Use In De-ion DH Switchgear. Operating Voltage, Control Voltages, Wiring, and Additional Accessories to be determined before ordering.
From Get Price
Limited Stock
A4KES300T5
A4KES300T5
Cutler Hammer - Rating Plug
A4KES300T5, Cutler Hammer, Series C, type KES, interchangeable rating plug element, rated for 320-320A, suitable for use with the 400A current sensor rating, to be used with Series C- KD,DK,KDB,HKD,HKDB,KDC,CKD,CHKD molded case circuit breaker frame types, for use with DIGITRIP,RMS310,KES solid state electronic trip units & circuit breakers
From Get Price
Limited Stock
MP25H2-3P-2500A-MO-BO-LI
MP25H2-3P-2500A-MO-BO-LI
Merlin Gerin - Insulated Case
MP25H2-3P-2500A-MO-BO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2500A frame, includes 2500A sensor rating with 2500A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
In Stock
KB3125T
KB3125T
Westinghouse - Trip Units And Programmers
KB3125T, Westinghouse, AB DE-ION, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 125A, suitable for 250A- KB,HKB standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From $312.24
Limited Stock
MP25H-3P-2500A-MO-BO-LS
MP25H-3P-2500A-MO-BO-LS
Merlin Gerin - Insulated Case
MP25H-3P-2500A-MO-BO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2500A frame, includes 2500A sensor rating with 2500A rating plug, 3P, 3PH, 600V, 75kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
150-DHP-750-FG-R-2000A
150-DHP-750-FG-R-2000A
Merlin Gerin - Vacuum Circuit Breaker
150-DHP-750-FG-R-2000A, Merlin Gerin, DHP-FG-R Series, , 3PH, 3P, 15000 VAC, 2000 Frame, Electrically Operated, Draw-Out, Medium Voltage vacuum circuit breaker Retrofit, Retrofitted for 150-DHP-750, For Use In Porcel-line DHP Switchgear. Operating Voltage, Control Voltages, Wiring, and Additional Accessories to be determined before ordering.
From Get Price
Limited Stock
8539SJW43V08H30
8539SJW43V08H30
Square D - Motor Starter
8539SJW43V08H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 7, requires 3 thermal units, supplied with MAG-GARD MAL361000-47M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 300 HP @ 240V, complete with 208V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price
Limited Stock
8539SDW53V02H30
8539SDW53V02H30
Square D - Motor Starter
8539SDW53V02H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 2, requires 3 thermal units, supplied with MAG-GARD GJL36050-M05 circuit breaker and NEMA type 4X enclosure, 3P, 3PH, 600V, 10 HP @ 240V, complete with 120V 60Hz/110V 50Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price
Limited Stock
8539SCG44V01H20
8539SCG44V01H20
Square D - Motor Starter
8539SCG44V01H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 1, requires 3 thermal units, supplied with MAG-GARD GJL36030-M04 circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 5 -7 1/2 HP @ 240V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price
Limited Stock
CR306HXS003
CR306HXS003
General Electric - Motor Starter
CR306HXS003, General Electric, 300 Line, type , 3P, 3PH, 540A, 600V, 200 hp, complete with 230V-240V 50/60Hz, AC coil, non-reversing, non-combination open type magnetic starter, NEMA size 6, equipped with overload rely to provide 130.0-270.0A with 1200 max fuse rating, 800 max breaker rating, suitable for use with CR306 motor control systems
From Get Price
Limited Stock
8539SDA52V03
8539SDA52V03
Square D - Motor Starter
8539SDA52V03, Square D, Class 8539, combination non-reversing motor starter, NEMA size 2, requires 3 thermal units, supplied with MAG-GARD GJL36030-M04 circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 5-7 1/2 HP @ 240V, complete with 240V coil, suitable for use with Class 8539 motor control systems
From Get Price
Limited Stock
KPRL4BCED
KPRL4BCED
Challenger - Mounting Hardware
KPRL4BCED direct replacement mounting hardware for Challenger, Cutler Hammer, Eaton, Westinghouse PM4b bolt-on style panel boards, rated for 225A 600V max, Copper, Dual/Twin Branch mounting style, suitable for use with CE,CF,CFS,CFH,ED,EDB,EDH,EHD,FD,FDB,FDC,HFD,HMCP,E2F,FWF circuit breaker frames, complete with all associated hardware, screws and cover plates
From Get Price
Limited Stock
PKA36080U64AE1RE10
PKA36080U64AE1RE10
Schneider Electric - Molded Case
PKA36080U64AE1RE10, Square D, Schneider Electric, PowerPact, type , 3P, ABC phase connection, 3PH, 800A, 600V, 50kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, complete with door mounted standard black handle, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breaker
From Get Price
In Stock
CR306FXM003
CR306FXM003
General Electric - Motor Starter
CR306FXM003, General Electric, 300 Line, type , 3P, 3PH, 135A, 600V, 50 hp, complete with 230V-240V 50/60Hz, AC coil, non-reversing, non-combination open type magnetic starter, NEMA size 3-4, equipped with overload rely to provide 65.0-135.0A with 500 max fuse rating, 400 max breaker rating, suitable for use with CR306 motor control systems
From $2,087.67
Limited Stock
MP63H2-3P-6000A-EO-BO-LIG
MP63H2-3P-6000A-EO-BO-LIG
Merlin Gerin - Insulated Case
MP63H2-3P-6000A-EO-BO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 6300A frame, includes 6300A sensor rating with 6000A rating plug, 3P, 3PH, 600V, 125kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
TQC1115WL
TQC1115WL
General Electric - Molded Case
TQC1115WL, General Electric, Q-Line, type , 1P, 1PH, 120/240V, 15A, 5kA@120V, UL listed, standard interrupting capacity, Feed-Thru, LI - Long-Time and Instantaneous trip functions, line & load side lug terminals, for use with PowerMark circuit breaker load centers, Thermal Magnetic molded case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
LC12100
LC12100
Square D - Bell Alarm
LC12100, Square D, Square D Series, type , bell alarm, (1) alarm switch, rated for Vac/28Vdc, when installed in a circuit breaker the part number suffix is -2100, suitable for use with LC,LCF,LCL,LCP,LE,LEF,LEL,LEP,LI,LIF,LIL,LIP,LX,LXF,LXL,LXP,LXI,LXIF,LXIL,LXIP frame bell alarm circuit breakers
From Get Price