1. Home / 
  2. breaker

SORT BY
Limited Stock
SSB1G3Q7F
SSB1G3Q7F
General Electric - Insulated Case
SSB1G3Q7F, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication & ZSI features and 300A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD2G4Q4K
SSD2G4Q4K
General Electric - Insulated Case
SSD2G4Q4K, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 1600A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT, modbus communication & ZSI features and 600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHF2G467P
SHF2G467P
General Electric - Insulated Case
SHF2G467P, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 1600A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, modbus communication & ZSI features and 1000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD4G6W7W
SSD4G6W7W
General Electric - Insulated Case
SSD4G6W7W, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communcation, relays & ZSI features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHF5G817W
SHF5G817W
General Electric - Insulated Case
SHF5G817W, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, front connected, 3000A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, current metering, RELT & ZSI features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHD5G8W4R
SHD5G8W4R
General Electric - Insulated Case
SHD5G8W4R, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 150kA@480V, high interrupting capacity, Draw-Out, 3000A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT, modbus communication, relays & ZSI features and 1200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHB4G657N
SHB4G657N
General Electric - Insulated Case
SHB4G657N, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communcation & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD2G583N
SSD2G583N
General Electric - Insulated Case
SSD2G583N, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 1600A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication, relays & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSB2G526P
SSB2G526P
General Electric - Insulated Case
SSB2G526P, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 1600A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering, RELT, modbus communication & ZSI features and 1000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSB5G8F7U
SSB5G8F7U
General Electric - Insulated Case
SSB5G8F7U, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, back connected, 3000A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering & modbus communication features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSB3G636U
SSB3G636U
General Electric - Insulated Case
SSB3G636U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 2000A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering, modbus communication & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSF5G8Y4U
SSF5G8Y4U
General Electric - Insulated Case
SSF5G8Y4U, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, front connected, 3000A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, modbus communication, relays & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHF2G5Q7U
SHF2G5Q7U
General Electric - Insulated Case
SHF2G5Q7U, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 1600A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHF4G6Y7R
SHF4G6Y7R
General Electric - Insulated Case
SHF4G6Y7R, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, modbus communcation, relays & ZSI features and 1200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHD5G8W72
SHD5G8W72
General Electric - Insulated Case
SHD5G8W72, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 150kA@480V, high interrupting capacity, Draw-Out, 3000A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication, relays & ZSI features and 3000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHB2G5H3N
SHB2G5H3N
General Electric - Insulated Case
SHB2G5H3N, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 1600A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication & relays features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHB1G3J4L
SHB1G3J4L
General Electric - Insulated Case
SHB1G3J4L, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, modbus communication and relays features and 700A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD4G6W4P
SSD4G6W4P
General Electric - Insulated Case
SSD4G6W4P, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT, modbus communcation, relays & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHF1G297C
SHF1G297C
General Electric - Insulated Case
SHF1G297C, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, modbus communication, relays & ZSI features and 200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD4G486H
SSD4G486H
General Electric - Insulated Case
SSD4G486H, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, full metering, RELT, modbus communication, relays & ZSI features and 400A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSB2G5W6T
SSB2G5W6T
General Electric - Insulated Case
SSB2G5W6T, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 1600A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, full metering, RELT, modbus communication, relays & ZSI features and 1500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSB4G6L7T
SSB4G6L7T
General Electric - Insulated Case
SSB4G6L7T, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, current metering, RELT & ZSI features and 1500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSF4G7B3W
SSF4G7B3W
General Electric - Insulated Case
SSF4G7B3W, General Electric, Power Break II, type , 3P, 3PH, 600V, 2500A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering, RELT & modbus communication features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHB1G2N6C
SHB1G2N6C
General Electric - Insulated Case
SHB1G2N6C, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering, modbus communication & ZSI features and 200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price