1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
8539SEW42V07H20
8539SEW42V07H20
Square D - Motor Starter
8539SEW42V07H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 3, requires 3 thermal units, supplied with MAG-GARD FAL36100-18M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 40-50 HP @ 600V, complete with 600V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price
Limited Stock
AKR-8AE-50-MO-DO-LSG
AKR-8AE-50-MO-DO-LSG
General Electric - Air
AKR-8AE-50-MO-DO-LSG, General Electric, Manually Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with Epic MicroVersa Trip Solid State Overcurrent Protection, LSG - Long-Time, Short-Time and Ground Fault trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
Limited Stock
MP20-3P-1000A
MP20-3P-1000A
Merlin Gerin - Insulated Case
MP20-3P-1000A, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2000A frame includes 1200A, 1600A or 2000A sensor rating with 1000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
AKR-10A-75-MO-DO-LI
AKR-10A-75-MO-DO-LI
General Electric - Air
AKR-10A-75-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 3200A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with MicroVersa Trip Plus - Gen 1 Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
In Stock
TQP230
TQP230
General Electric - Molded Case
TQP230, General Electric, PowerMark, type , 2P, 1PH, 120/240V, 30A, 5kA@240V, UL listed, standard interrupting capacity, enclosure compensated, Plug-In, LI - Long-Time and Instantaneous trip functions, load side lug terminals, for use with PowerMark circuit breaker load centers, Thermal Magnetic molded case circuit breakers; these breakers are obsolete, however we still stock them
From $45.45
Limited Stock
MP50H-3P-5000A-MO-BO-LS
MP50H-3P-5000A-MO-BO-LS
Merlin Gerin - Insulated Case
MP50H-3P-5000A-MO-BO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 5000A frame, includes 5000A sensor rating with 5000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
8539SDG43V02H30
8539SDG43V02H30
Square D - Motor Starter
8539SDG43V02H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 2, requires 3 thermal units, supplied with MAG-GARD GJL36050-M05 circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 10 HP @ 240V, complete with 120V 60Hz/110V 50Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price
Limited Stock
8539SBG43V01H20
8539SBG43V01H20
Square D - Motor Starter
8539SBG43V01H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size , requires 3 thermal units, supplied with MAG-GARD GJL36015-M03 circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 1 1/2-3 HP @ 240V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price
Limited Stock
MP12H-3P-1000A-EO-BO-LS
MP12H-3P-1000A-EO-BO-LS
Merlin Gerin - Insulated Case
MP12H-3P-1000A-EO-BO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1200A frame with 1200A sensor rating with 1000A rating plug, 3P, 3PH, 600V, 65kA@480V, acceptable with the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP30-3P-3000A-EO-BO-LSG
MP30-3P-3000A-EO-BO-LSG
Merlin Gerin - Insulated Case
MP30-3P-3000A-EO-BO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3000A frame includes 3000A sensor rating with 3000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
8539SJA43V02H20
8539SJA43V02H20
Square D - Motor Starter
8539SJA43V02H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 7, requires 3 thermal units, supplied with MAG-GARD MAL361000-47M circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 250-300 HP @ 240V, complete with 120V 60Hz/110V 50Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price
Limited Stock
8539SHG45V03H10
8539SHG45V03H10
Square D - Motor Starter
8539SHG45V03H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD MAL36600-42M circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 350 HP @ 480V, complete with 240V 60Hz/220V 50Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price
Limited Stock
PKA36120U64AE1AB
PKA36120U64AE1AB
Square D - Molded Case
PKA36120U64AE1AB, Schneider Electric, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 1200A, 600V, 50kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, complete with 2A/2B auxiliary switch, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breaker
From Get Price
In Stock
LB3250T
LB3250T
Westinghouse - Trip Units And Programmers
LB3250T, Westinghouse, AB DE-ION, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 250A, suitable for 400A- LB,HLB standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From $500.93
Limited Stock
MA2700TV
MA2700TV
Westinghouse - Trip Units And Programmers
MA2700TV, Westinghouse, MA Series, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 700A, 50°C, suitable for 800A- MA,HMA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
Limited Stock
MP20H-3P-1000A
MP20H-3P-1000A
Merlin Gerin - Insulated Case
MP20H-3P-1000A, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2000A frame, includes 1200A, 1600A or 2000A sensor rating with 1000A rating plug, 3P, 3PH, 600V, 75kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
8539SJW43V08H20
8539SJW43V08H20
Square D - Motor Starter
8539SJW43V08H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 7, requires 3 thermal units, supplied with MAG-GARD MAL361000-47M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 300 HP @ 240V, complete with 208V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price
Limited Stock
ECN24A4DA7
ECN24A4DA7
Cutler Hammer - Motor Starter
ECN24A4DA7, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP and CPT (control power transformers), type , 3P, 3PH, 2 HP @ 575V, 600V, complete with 600V coil, NEMA size 00, 15A HMCP circuit breaker enclosed in NEMA Type 4X 304-grade watertight & dust-tight stainless steel enclosure, suitable for use with Freedom Series motor control systems
From Get Price
Limited Stock
HMA2600TV
HMA2600TV
Westinghouse - Trip Units And Programmers
HMA2600TV, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 600A, 50°C, suitable for 800A- MA,HMA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
Limited Stock
MP16-3P-800A-EO-BO-LSI
MP16-3P-800A-EO-BO-LSI
Merlin Gerin - Insulated Case
MP16-3P-800A-EO-BO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1600A frame with 1600A sensor rating with 800A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP30H2-3P-3000A-EO-BO-LSG
MP30H2-3P-3000A-EO-BO-LSG
Merlin Gerin - Insulated Case
MP30H2-3P-3000A-EO-BO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3000A frame, includes 3000A sensor rating with 3000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
ECN2204BAD-E3
ECN2204BAD-E3
Cutler Hammer - Motor Starter
ECN2204BAD-E3, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP, type , 3P, 3PH, 3 HP @ 230V, 600V, complete with 240V coil, NEMA size , 15A HMCP circuit breaker enclosed in oversize NEMA Type 4X 304-grade watertight & dust-tight stainless steel enclosure without control transformer, suitable for use with Freedom Series motor control systems
From Get Price
Limited Stock
MP63H2-3P-6000A-EO-DO-LSI
MP63H2-3P-6000A-EO-DO-LSI
Merlin Gerin - Insulated Case
MP63H2-3P-6000A-EO-DO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 6300A frame, includes 6300A sensor rating with 6000A rating plug, 3P, 3PH, 600V, 125kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
8539SHA45V04H20
8539SHA45V04H20
Square D - Motor Starter
8539SHA45V04H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD MAL36600-42M circuit breaker and NEMA type 12/3R without external reset enclosure, 3P, 3PH, 600V, 350 HP @ 480V, complete with 277V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price