


- Home /
15 amp breaker
97,864 Results
Refine Results
In Stock
Subcategory
SORT BY

HMA2225TV
Westinghouse - Trip Units And Programmers
HMA2225TV, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 225A, 50°C, suitable for 800A- MA,HMA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

AKRT-9A-50H-MO-DO-LI
General Electric - Air
AKRT-9A-50H-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 2000A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with MicroVersa Trip Plus - Gen 1 Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

PJA36040U64AE1BD
Schneider Electric - Molded Case
PJA36040U64AE1BD, Square D, Schneider Electric, PowerPact, type , 3P, ABC phase connection, 3PH, 400A, 600V, 65kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, complete with 1A/1B overcurrent trip switch, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breaker
From Get Price

8539SHA56V06H30
Square D - Motor Starter
8539SHA56V06H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD LAL36600-44M circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 400 HP @ 480V, complete with 480V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price

8539SBG43V08H30
Square D - Motor Starter
8539SBG43V08H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size , requires 3 thermal units, supplied with MAG-GARD GJL36015-M03 circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 1 1/2-3HP @ 208V, complete with 208V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price

MP25H2-3P-2500A-MO-BO-LSG
Merlin Gerin - Insulated Case
MP25H2-3P-2500A-MO-BO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2500A frame, includes 2500A sensor rating with 2500A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

8539SHG46V01H30
Square D - Motor Starter
8539SHG46V01H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD LAL36600-44M circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 200 HP @ 240V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price

8539SHA45V03
Square D - Motor Starter
8539SHA45V03, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD MAL36600-42M circuit breaker and NEMA type 12/3R without external reset enclosure, 3P, 3PH, 600V, 350 HP @ 480V, complete with 240V 60Hz/220V 50Hz coil, suitable for use with Class 8539 motor control systems
From Get Price

MP12-3P-1200A-MO-BO-LI
Merlin Gerin - Insulated Case
MP12-3P-1200A-MO-BO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1200A frame with 1200A sensor rating with 1200A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

CR306CXH004
General Electric - Motor Starter
CR306CXH004, General Electric, 300 Line, type , 3P, 3PH, 27A, 600V, 10 hp, complete with 460V-480V 50/60Hz, AC coil, non-reversing, non-combination open type magnetic starter, NEMA size 00-2, equipped with overload rely to provide 13.0-27.0A with 100 max fuse rating, 100 max breaker rating, suitable for use with CR306 motor control systems
From Get Price

MP08-3P-150A-EO-DO-LSG
Merlin Gerin - Insulated Case
MP08-3P-150A-EO-DO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 800A frame with 250A trip and 150A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP63H-3P-6300A-MO-DO-LIG
Merlin Gerin - Insulated Case
MP63H-3P-6300A-MO-DO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 6300A frame, includes 6300A sensor rating with 6300A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

8539SCA54V06H10
Square D - Motor Starter
8539SCA54V06H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 1, requires 3 thermal units, supplied with MAG-GARD GJL36030-M04 circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 10 HP @ 480V, complete with 480V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price

MP50-3P-5000A-EO-BO-LSI
Merlin Gerin - Insulated Case
MP50-3P-5000A-EO-BO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 5000A frame includes 5000A sensor rating with 5000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

8539SFW44V06H30
Square D - Motor Starter
8539SFW44V06H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 4, requires 3 thermal units, supplied with MAG-GARD KAL36250-29M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 100 HP @ 480V, complete with 480V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price

MP30H2-3P-3000A-MO-DO-LS
Merlin Gerin - Insulated Case
MP30H2-3P-3000A-MO-DO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3000A frame, includes 3000A sensor rating with 3000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

HKB3200TA
Westinghouse - Trip Units And Programmers
HKB3200TA, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 200A, 50°C, suitable for 250A- KB,HKB standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price

HMA2700T
Westinghouse - Trip Units And Programmers
HMA2700T, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 700A, suitable for 800A- MA,HMA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From $1,292.96

8539SFG44V02H10
Square D - Motor Starter
8539SFG44V02H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 4, requires 3 thermal units, supplied with MAG-GARD KAL36250-29M circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 50 HP @ 240V, complete with 120V 60Hz/110V 50Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price

MP20-3P-2000A-EO-BO-LSI
Merlin Gerin - Insulated Case
MP20-3P-2000A-EO-BO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2000A frame includes 2000A sensor rating with 2000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

HLB3175TA
Westinghouse - Trip Units And Programmers
HLB3175TA, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 175A, 50°C, suitable for 400A- LB,HLB standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price

MP40H2-3P-4000A-MO-BO-LI
Merlin Gerin - Insulated Case
MP40H2-3P-4000A-MO-BO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 4000A frame, includes 4000A sensor rating with 4000A rating plug, 3P, 3PH, 600V, 125kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

8539SJA43V08H20
Square D - Motor Starter
8539SJA43V08H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 7, requires 3 thermal units, supplied with MAG-GARD MAL361000-47M circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 250-300 HP @ 240V, complete with 208V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price

BE-TR40S3000
BRAH Electric - Rating Plug
BE-TR40S3000, BRAH Electric, Power Break I, type , substitute rating plug element, rated for 3000A, 4000A sensor rating, suitable for use with 4000A - TP, TC, THP, THC, AKR100 draw-out style only, insulated case and low voltage power air circuit breaker frame types, for use with MicroVersaTrip RMS-9, MicroVersaTrip Plus, MicroVersaTrip PM trip units & circuit breakers
From Get Price