- Home /
15 amp breaker
97,864 Results
Refine Results
In Stock
Subcategory
SORT BY

1241C54G05
Eaton - Molded Case
1241C54G05, Eaton, Naval, type , consists of L400QM breaker frame with adapter kit, 3P, 3PH, 250A-400A, 500Vac, 150kA@500V, Plug-In, complete with 450Vac shunt trip and 1A/1B aux switch, non-interchangeable trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, molded case circuit breakers for naval shipboard use
From Get Price

MP20-3P-2000A-MO-BO-LSG
Merlin Gerin - Insulated Case
MP20-3P-2000A-MO-BO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2000A frame includes 2000A sensor rating with 2000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

HLA2300TV
Westinghouse - Trip Units And Programmers
HLA2300TV, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 300A, 50°C, suitable for 400A- LA,HLA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price

8539SGW44V04H10
Square D - Motor Starter
8539SGW44V04H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 5, requires 3 thermal units, supplied with MAG-GARD LAL36400-32M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 75 HP @ 240V, complete with 277V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price

ECN2204CAD-E3
Cutler Hammer - Motor Starter
ECN2204CAD-E3, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP, type , 3P, 3PH, 5 HP @ 460V, 600V, complete with 480V coil, NEMA size , 15A HMCP circuit breaker enclosed in oversize NEMA Type 4X 304-grade watertight & dust-tight stainless steel enclosure without control transformer, suitable for use with Freedom Series motor control systems
From Get Price

JT3100TS41
Cutler Hammer - Trip Units And Programmers
JT3100TS41, Cutler Hammer, Series C, type , trip units and programmers, interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 100A, suitable for HJDDC,JD,HJD,JDC molded case circuit breaker frame types, left pole mounted 12-24Vac/dc shunt trip, 18-inch pigtail leads same side, Thermal Magnetic trip units & circuit breakers
From Get Price

8539SCG45V06H10
Square D - Motor Starter
8539SCG45V06H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 1, requires 3 thermal units, supplied with MAG-GARD GJL36050-M05 circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 7 1/2 HP @ 208V, complete with 480V 60Hz/440V 50Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price

S141E
Merlin Gerin - Trip Units And Programmers
S141E, Merlin Gerin, Schneider Electric, Square D, Micrologic, field installable Micrologic standard 3.0A trip unit with LI - Long-Time and Instantaneous trip functions and ammeter, with type 'E' rating plug, suitable for NS,NT,NW,PG,PJ,PK,PL,RG,RJ,RK,RL molded case & insulated case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From $1,661.45

PLA36060U64AE1YP
Square D - Molded Case
PLA36060U64AE1YP, Square D, Schneider Electric, PowerPact, type , 3P, ABC phase connection, 3PH, 600A, 600V, 100kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, complete with fixed handle padlocking device, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breaker
From Get Price

AKR-8S-50H-MO-BI-LSG
General Electric - Air
AKR-8S-50H-MO-BI-LSG, General Electric, Manually Operated, Bolt-In, Low Voltage air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with Epic MicroVersa Trip Solid State Overcurrent Protection, LSG - Long-Time, Short-Time and Ground Fault trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

ECN2218EAE-E3R5
Cutler Hammer - Motor Starter
ECN2218EAE-E3R5, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP, type , 3P, 3PH, 7.5 HP @ 200V, 600V, complete with 208V coil, NEMA size 1, 30A HMCP circuit breaker enclosed in oversize NEMA Type 12 dust-tight industrial enclosure with internal reset, without control transformer, suitable for use with Freedom Series motor control systems
From Get Price

LA2125TA
Westinghouse - Trip Units And Programmers
LA2125TA, Westinghouse, LA Series, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 125A, 50°C, suitable for 400A- LA,HLA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price

MP16H2-3P-1600A-MO-DO-LI
Merlin Gerin - Insulated Case
MP16H2-3P-1600A-MO-DO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1600A frame, includes 1600A sensor rating with 1600A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP16-3P-800A-EO-BO-LSIG
Merlin Gerin - Insulated Case
MP16-3P-800A-EO-BO-LSIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1600A frame with 1600A sensor rating with 800A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

AKRT-8S-50H-MO-BI-LSG
General Electric - Air
AKRT-8S-50H-MO-BI-LSG, General Electric, Manually Operated, Bolt-In, Low Voltage air circuit breaker, AKR Series, Type , 2000A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with Epic MicroVersa Trip Solid State Overcurrent Protection, LSG - Long-Time, Short-Time and Ground Fault trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

MP32-3P-3200A-MO-BO-LSIG
Merlin Gerin - Insulated Case
MP32-3P-3200A-MO-BO-LSIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3200A frame includes 3200A sensor rating with 3200A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP16-3P-800A-EO-BO-LSI
Merlin Gerin - Insulated Case
MP16-3P-800A-EO-BO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1600A frame with 1600A sensor rating with 800A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

TQL11W15
General Electric - Molded Case
TQL11W15, General Electric, Q-Line, type , 1P, 1PH, 120/240V, 15A, 5kA@120V, common trip, UL listed, standard interrupting capacity, Plug-In, LI - Long-Time and Instantaneous trip functions, load side lug terminals, for use with PowerMark circuit breaker load centers, Thermal Magnetic, molded case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price

8539SCR43V08
Square D - Motor Starter
8539SCR43V08, Square D, Class 8539, combination non-reversing motor starter, NEMA size 00, requires 3 thermal units, supplied with MAG-GARD GJL36015-M03 circuit breaker and NEMA type 7 & 9 spin top type enclosure, 3P, 3PH, 600V, 1 1/2-3 HP @ 208V, complete with 208V coil, suitable for use with Class 8539 motor control systems
From Get Price

MP25-3P-2500A-EO-DO-LS
Merlin Gerin - Insulated Case
MP25-3P-2500A-EO-DO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2500A frame includes 2500A sensor rating with 2500A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

HLA3500TA
Westinghouse - Trip Units And Programmers
HLA3500TA, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 500A, 50°C, suitable for 600A- LA,HLA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price

8539SGG45V07H10
Square D - Motor Starter
8539SGG45V07H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 5, requires 3 thermal units, supplied with MAG-GARD LAL36400-33M circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 75 HP @ 208V, complete with 600V 60Hz/550V 50Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price

MP30H2-3P-3000A-EO-DO-LS
Merlin Gerin - Insulated Case
MP30H2-3P-3000A-EO-DO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3000A frame, includes 3000A sensor rating with 3000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

HMA2600TV
Westinghouse - Trip Units And Programmers
HMA2600TV, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 600A, 50°C, suitable for 800A- MA,HMA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price