MP32H2-3P-3200A-EO-BO-LSI
Merlin Gerin - Insulated Case
MP32H2-3P-3200A-EO-BO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3200A frame, includes 3200A sensor rating with 3200A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

ECN2208DA5-E3R5
Cutler Hammer - Motor Starter
ECN2208DA5-E3R5, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP, type , 3P, 3PH, 1 HP @ 575V, 600V, complete with 600V coil, NEMA size , 3A HMCP circuit breaker enclosed in oversize NEMA Type 12 dust-tight industrial enclosure with internal reset, without control transformer, suitable for use with Freedom Series motor control systems
From Get Price

MP16-3P-1600A-MO-BO-LIG
Merlin Gerin - Insulated Case
MP16-3P-1600A-MO-BO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1600A frame includes 1600A trip with 1600A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

8539SHA46V03H20
Square D - Motor Starter
8539SHA46V03H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD MAL36600-44M circuit breaker and NEMA type 12/3R without external reset enclosure, 3P, 3PH, 600V, 200 HP @ 240V, complete with 240V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price

PJA36040U64AE1RE10
Square D - Molded Case
PJA36040U64AE1RE10, Square D, Schneider Electric, PowerPact, type , 3P, ABC phase connection, 3PH, 400A, 600V, 65kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, complete with door mounted standard black handle, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breaker
From Get Price

MP12H2-3P-1200A-MO-DO-LSIG
Merlin Gerin - Insulated Case
MP12H2-3P-1200A-MO-DO-LSIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1200A frame, includes 1200A sensor rating with 1200A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

8539SBG43V03H30
Square D - Motor Starter
8539SBG43V03H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size , requires 3 thermal units, supplied with MAG-GARD GJL36015-M03 circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 1 1/2-3 HP @ 240V, complete with 240V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price

5683D88G26
Westinghouse - Trip Units And Programmers
5683D88G26, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 250A, 50°C, suitable for 600A- LA,HLA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price

CFD4BK
Challenger - Mounting Hardware
CFD4BK, PCS direct replacement mounting hardware for Challenger PM4b bolt-on style panel boards, rated for 150A 600V max, Copper, Dual/Twin Branch mounting style, suitable for use with CE,CF,CFS,CFH,ED,EDB,EDH,EHD,FD,FDB,FDC,HFD,HMCP,E2F,FWF circuit breaker frames, complete with all associated hardware, screws and cover plates
From $209.95

AKR-10S-50-MO-BI-LI
General Electric - Air
AKR-10S-50-MO-BI-LI, General Electric, Manually Operated, Bolt-In, Low Voltage air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with MicroVersa Trip Plus - Gen 2 Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

MP08-3P-125A-EO-BO-LI
Merlin Gerin - Insulated Case
MP08-3P-125A-EO-BO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 800A frame with 250A trip and 125A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

M3SRG2500
Eaton - Rating Plug
M3SRG2500, Eaton, Magnum DS, rating plug, field installable kit for changing the sensor/rating plug rating on fixed or drawout circuit breakers, includes 1 rating plug plus 3 sensors for 3 pole breakers, rated for 2500A, suitable for use with standard frame MDS air circuit breaker frame types, for use with Digitrip 220,520,520M,520MC,1150 solid state programmers
From Get Price

8539SJW43V01H30
Square D - Motor Starter
8539SJW43V01H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 7, requires 3 thermal units, supplied with MAG-GARD MAL361000-47M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 300 HP @ 240V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price

AKR-8AE-50-MO-DO-LSG
General Electric - Air
AKR-8AE-50-MO-DO-LSG, General Electric, Manually Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with Epic MicroVersa Trip Solid State Overcurrent Protection, LSG - Long-Time, Short-Time and Ground Fault trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

PKA36060U64AE1AC
Square D - Molded Case
PKA36060U64AE1AC, Square D, Schneider Electric, PowerPact, type , 3P, ABC phase connection, 3PH, 600A, 600V, 50kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, complete with 3A/3B auxiliary switch, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breaker
From Get Price

0209B8104G006
General Electric - Control Part
0209B8104G006 / <strong>0282A7015G010</strong>, General Electric, General Electric, PowerVac, Trip Coil *Single & Dual*, 250VDC (5 Cycle), VB-1 0,1,2,3, ML-18, qty 1 needed per breaker, suitable for VB1 4.16-250 (1200 & 2000A), VB1 4.16-350 (1200, 2000, 3000A), VB1 7.2-500 (1200 & 2000A), VB1 13.8-500 (1200 & 2000A), VB1 13.8-750 (1200 & 2000A), VB1 13.8-1000 (1200, 2000, 3000A) breakers
From Get Price

AKRU-5B-50-MO-DO-LI
General Electric - Air
AKRU-5B-50-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage Fused air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with ECS Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor, Rating Plug and Fuse Amperages available
From Get Price

8539SGA54V06H10
Square D - Motor Starter
8539SGA54V06H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 5, requires 3 thermal units, supplied with MAG-GARD LAL36400-32M circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 150 HP @ 480V, complete with 480V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price

MP40H2-3P-4000A-EO-BO-LSI
Merlin Gerin - Insulated Case
MP40H2-3P-4000A-EO-BO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 4000A frame, includes 4000A sensor rating with 4000A rating plug, 3P, 3PH, 600V, 125kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP40H-3P-4000A-MO-BO-LSI
Merlin Gerin - Insulated Case
MP40H-3P-4000A-MO-BO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 4000A frame, includes 4000A sensor rating with 4000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

ECN24A8BAC
Cutler Hammer - Motor Starter
ECN24A8BAC, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP and CPT (control power transformers), type , 3P, 3PH, 1.5 HP @ 230V, 600V, complete with 240V coil, NEMA size 00, 7A HMCP circuit breaker enclosed in NEMA Type 12 dust-tight industrial enclosure with external reset, suitable for use with Freedom Series motor control systems
From Get Price

MP50-3P-4000A
Merlin Gerin - Insulated Case
MP50-3P-4000A, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 5000A frame includes 4000A or 5000A sensor rating with 4000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP25-3P-2500A-EO-BO-LSG
Merlin Gerin - Insulated Case
MP25-3P-2500A-EO-BO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2500A frame includes 2500A sensor rating with 2500A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

PKA36040U64AE1BC
Schneider Electric - Molded Case
PKA36040U64AE1BC, Square D, Schneider Electric, PowerPact, type , 3P, ABC phase connection, 3PH, 400A, 600V, 50kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, complete with 1A/1B alarm switch, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breaker