MP32H2-3P-3200A-EO-BO-LSI
MP32H2-3P-3200A-EO-BO-LSI
Merlin Gerin - Insulated Case
MP32H2-3P-3200A-EO-BO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3200A frame, includes 3200A sensor rating with 3200A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
ECN2208DA5-E3R5
ECN2208DA5-E3R5
Cutler Hammer - Motor Starter
ECN2208DA5-E3R5, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP, type , 3P, 3PH, 1 HP @ 575V, 600V, complete with 600V coil, NEMA size , 3A HMCP circuit breaker enclosed in oversize NEMA Type 12 dust-tight industrial enclosure with internal reset, without control transformer, suitable for use with Freedom Series motor control systems
From Get Price
Limited Stock
MP16-3P-1600A-MO-BO-LIG
MP16-3P-1600A-MO-BO-LIG
Merlin Gerin - Insulated Case
MP16-3P-1600A-MO-BO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1600A frame includes 1600A trip with 1600A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
8539SHA46V03H20
8539SHA46V03H20
Square D - Motor Starter
8539SHA46V03H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD MAL36600-44M circuit breaker and NEMA type 12/3R without external reset enclosure, 3P, 3PH, 600V, 200 HP @ 240V, complete with 240V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price
Limited Stock
PJA36040U64AE1RE10
PJA36040U64AE1RE10
Square D - Molded Case
PJA36040U64AE1RE10, Square D, Schneider Electric, PowerPact, type , 3P, ABC phase connection, 3PH, 400A, 600V, 65kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, complete with door mounted standard black handle, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breaker
From Get Price
Limited Stock
MP12H2-3P-1200A-MO-DO-LSIG
MP12H2-3P-1200A-MO-DO-LSIG
Merlin Gerin - Insulated Case
MP12H2-3P-1200A-MO-DO-LSIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1200A frame, includes 1200A sensor rating with 1200A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
8539SBG43V03H30
8539SBG43V03H30
Square D - Motor Starter
8539SBG43V03H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size , requires 3 thermal units, supplied with MAG-GARD GJL36015-M03 circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 1 1/2-3 HP @ 240V, complete with 240V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price
Limited Stock
5683D88G26
5683D88G26
Westinghouse - Trip Units And Programmers
5683D88G26, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 250A, 50°C, suitable for 600A- LA,HLA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price
In Stock
CFD4BK
CFD4BK
Challenger - Mounting Hardware
CFD4BK, PCS direct replacement mounting hardware for Challenger PM4b bolt-on style panel boards, rated for 150A 600V max, Copper, Dual/Twin Branch mounting style, suitable for use with CE,CF,CFS,CFH,ED,EDB,EDH,EHD,FD,FDB,FDC,HFD,HMCP,E2F,FWF circuit breaker frames, complete with all associated hardware, screws and cover plates
From $209.95
Limited Stock
AKR-10S-50-MO-BI-LI
AKR-10S-50-MO-BI-LI
General Electric - Air
AKR-10S-50-MO-BI-LI, General Electric, Manually Operated, Bolt-In, Low Voltage air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with MicroVersa Trip Plus - Gen 2 Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
Limited Stock
MP08-3P-125A-EO-BO-LI
MP08-3P-125A-EO-BO-LI
Merlin Gerin - Insulated Case
MP08-3P-125A-EO-BO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 800A frame with 250A trip and 125A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
M3SRG2500
M3SRG2500
Eaton - Rating Plug
M3SRG2500, Eaton, Magnum DS, rating plug, field installable kit for changing the sensor/rating plug rating on fixed or drawout circuit breakers, includes 1 rating plug plus 3 sensors for 3 pole breakers, rated for 2500A, suitable for use with standard frame MDS air circuit breaker frame types, for use with Digitrip 220,520,520M,520MC,1150 solid state programmers
From Get Price
Limited Stock
8539SJW43V01H30
8539SJW43V01H30
Square D - Motor Starter
8539SJW43V01H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 7, requires 3 thermal units, supplied with MAG-GARD MAL361000-47M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 300 HP @ 240V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price
Limited Stock
AKR-8AE-50-MO-DO-LSG
AKR-8AE-50-MO-DO-LSG
General Electric - Air
AKR-8AE-50-MO-DO-LSG, General Electric, Manually Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with Epic MicroVersa Trip Solid State Overcurrent Protection, LSG - Long-Time, Short-Time and Ground Fault trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
Limited Stock
PKA36060U64AE1AC
PKA36060U64AE1AC
Square D - Molded Case
PKA36060U64AE1AC, Square D, Schneider Electric, PowerPact, type , 3P, ABC phase connection, 3PH, 600A, 600V, 50kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, complete with 3A/3B auxiliary switch, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breaker
From Get Price
Limited Stock
0209B8104G006
0209B8104G006
General Electric - Control Part
0209B8104G006 / <strong>0282A7015G010</strong>, General Electric, General Electric, PowerVac, Trip Coil *Single & Dual*, 250VDC (5 Cycle), VB-1 0,1,2,3, ML-18, qty 1 needed per breaker, suitable for VB1 4.16-250 (1200 & 2000A), VB1 4.16-350 (1200, 2000, 3000A), VB1 7.2-500 (1200 & 2000A), VB1 13.8-500 (1200 & 2000A), VB1 13.8-750 (1200 & 2000A), VB1 13.8-1000 (1200, 2000, 3000A) breakers
From Get Price
Limited Stock
AKRU-5B-50-MO-DO-LI
AKRU-5B-50-MO-DO-LI
General Electric - Air
AKRU-5B-50-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage Fused air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with ECS Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor, Rating Plug and Fuse Amperages available
From Get Price
Limited Stock
8539SGA54V06H10
8539SGA54V06H10
Square D - Motor Starter
8539SGA54V06H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 5, requires 3 thermal units, supplied with MAG-GARD LAL36400-32M circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 150 HP @ 480V, complete with 480V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price
Limited Stock
MP40H2-3P-4000A-EO-BO-LSI
MP40H2-3P-4000A-EO-BO-LSI
Merlin Gerin - Insulated Case
MP40H2-3P-4000A-EO-BO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 4000A frame, includes 4000A sensor rating with 4000A rating plug, 3P, 3PH, 600V, 125kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP40H-3P-4000A-MO-BO-LSI
MP40H-3P-4000A-MO-BO-LSI
Merlin Gerin - Insulated Case
MP40H-3P-4000A-MO-BO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 4000A frame, includes 4000A sensor rating with 4000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
ECN24A8BAC
ECN24A8BAC
Cutler Hammer - Motor Starter
ECN24A8BAC, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP and CPT (control power transformers), type , 3P, 3PH, 1.5 HP @ 230V, 600V, complete with 240V coil, NEMA size 00, 7A HMCP circuit breaker enclosed in NEMA Type 12 dust-tight industrial enclosure with external reset, suitable for use with Freedom Series motor control systems
From Get Price
Limited Stock
MP50-3P-4000A
MP50-3P-4000A
Merlin Gerin - Insulated Case
MP50-3P-4000A, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 5000A frame includes 4000A or 5000A sensor rating with 4000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP25-3P-2500A-EO-BO-LSG
MP25-3P-2500A-EO-BO-LSG
Merlin Gerin - Insulated Case
MP25-3P-2500A-EO-BO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2500A frame includes 2500A sensor rating with 2500A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
PKA36040U64AE1BC
PKA36040U64AE1BC
Schneider Electric - Molded Case
PKA36040U64AE1BC, Square D, Schneider Electric, PowerPact, type , 3P, ABC phase connection, 3PH, 400A, 600V, 50kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, complete with 1A/1B alarm switch, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breaker
From Get Price