- Home /
15 amp breaker
97,864 Results
Refine Results
In Stock
Subcategory
SORT BY

8539SFW44V01H10
Square D - Motor Starter
8539SFW44V01H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 4, requires 3 thermal units, supplied with MAG-GARD KAL36250-29M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 50 HP @ 240V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price

KA2090T
Westinghouse - Trip Units And Programmers
KA2090T, Westinghouse, KA Series, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 90A, suitable for 225A- KA,HKA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From $393.22

MP12H2-3P-1000A-EO-BO-LSG
Merlin Gerin - Insulated Case
MP12H2-3P-1000A-EO-BO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1200A frame, includes 1200A sensor rating with 1000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

M4RRG2000
Cutler Hammer - Rating Plug
M4RRG2000, Cutler Hammer, Magnum DS, rating plug, field installable kit for changing the sensor/rating plug rating on fixed or drawout circuit breakers, includes 1 rating plug plus 8 sensors for 4 pole breakers, rated for 2000A, suitable for use with double frame MDS air circuit breaker frame types, for use with Digitrip 220,520,520M,520MC,1150 solid state programmers
From Get Price

8539SFA54V06H30
Square D - Motor Starter
8539SFA54V06H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 4, requires 3 thermal units, supplied with MAG-GARD KAL36250-29M circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 100 HP @ 480V, complete with 480V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price

449D701G08
Eaton - Metering
449D701G08 / <strong>3A73103G11</strong>, Cutler Hammer, Eaton, Westinghouse, Cutler Hammer, Eaton, Westinghouse, DS Series, Metering Current Transformer 1200/5, RCT-1600, DSM-16, qty 3 required per breaker, suitable for use with DS-206, DSL-206, DS-206S, DS-206E, DS-416, DSL-416, DS-416H, DS-416S, DS-420, DSII-308, DSII-516, DSII-620 low voltage power air breakers
From Get Price

HKB2090TA
Westinghouse - Trip Units And Programmers
HKB2090TA, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 90A, 50°C, suitable for 250A- KB,HKB standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price

S133C
Square D - Trip Units And Programmers
S133C, Schneider Electric, Merlin Gerin, Square D, Micrologic, field installable Micrologic standard 5.0 trip unit with LSI - Long-Time, Short-Time and Instantaneous trip functions, with type 'C' rating plug, suitable for NS,NT,NW,PG,PJ,PK,PL,RG,RJ,RK,RL molded case & insulated case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From $1,612.58

PKA36080U64AE1AB
Schneider Electric - Molded Case
PKA36080U64AE1AB, Square D, Schneider Electric, PowerPact, type , 3P, ABC phase connection, 3PH, 800A, 600V, 50kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, complete with 2A/2B auxiliary switch, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breaker
From Get Price

MP08-3P-125A-EO-DO-LIG
Merlin Gerin - Insulated Case
MP08-3P-125A-EO-DO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 800A frame with 250A trip and 125A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

HMA3225T
Westinghouse - Trip Units And Programmers
HMA3225T, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 225A, suitable for 800A- MA,HMA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From $525.38

ECN2224EAF-E3
Cutler Hammer - Motor Starter
ECN2224EAF-E3, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP, type , 3P, 3PH, 10 HP @ 200V, 600V, complete with 208V coil, NEMA size 2, 50A HMCP circuit breaker enclosed in oversize NEMA Type 4X 304-grade watertight & dust-tight stainless steel enclosure without control transformer, suitable for use with Freedom Series motor control systems
From Get Price

8539SHW43V08H30
Square D - Motor Starter
8539SHW43V08H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD LAL36400-36M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 100 HP @ 208V, complete with 208V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price

MP08-3P-150A-MO-DO-LI
Merlin Gerin - Insulated Case
MP08-3P-150A-MO-DO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 800A frame with 250A trip and 150A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

PB28000TM
Westinghouse - Trip Units And Programmers
PB28000TM, Westinghouse, PB Series, type , interchangeable trip unit with I - Instantaneous trip functions, front adjustable, rear connected, rated for 2000A, suitable for PB,PA 2500A molded case circuit breaker frame types, magnetic trip range 3000-8000A, Magnetic Only trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

M3NRG1000
Cutler Hammer - Rating Plug
M3NRG1000, Cutler Hammer, Magnum DS, rating plug, field installable kit for changing the sensor/rating plug rating on fixed or drawout circuit breakers, includes 1 rating plug plus 3 sensors for 3 pole breakers, rated for 1000A, suitable for use with narrow frame MDN air circuit breaker frame types, for use with Digitrip 220,520,520M,520MC,1150 solid state programmers
From Get Price

8539SGW45V07H30
Square D - Motor Starter
8539SGW45V07H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 5, requires 3 thermal units, supplied with MAG-GARD LAL36400-33M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 75 HP @ 208V, complete with 600V 60Hz/550V 50Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price

MA2175TV
Westinghouse - Trip Units And Programmers
MA2175TV, Westinghouse, MA Series, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 175A, 50°C, suitable for 800A- MA,HMA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

HKA2100T
Westinghouse - Trip Units And Programmers
HKA2100T, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 100A, suitable for 225A- KA,HKA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From $274.82

MP30H-3P-3000A-MO-BO-LS
Merlin Gerin - Insulated Case
MP30H-3P-3000A-MO-BO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3000A frame, includes 3000A sensor rating with 3000A rating plug, 3P, 3PH, 600V, 75kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP40-3P-4000A-EO-DO-LSG
Merlin Gerin - Insulated Case
MP40-3P-4000A-EO-DO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 4000A frame includes 4000A sensor rating with 4000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

HMA2125TV
Westinghouse - Trip Units And Programmers
HMA2125TV, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 125A, 50°C, suitable for 800A- MA,HMA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

MP20H-3P-2000A-MO-BO-LSIG
Merlin Gerin - Insulated Case
MP20H-3P-2000A-MO-BO-LSIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2000A frame, includes 2000A sensor rating with 2000A rating plug, 3P, 3PH, 600V, 75kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

HLB2090TV
Westinghouse - Trip Units And Programmers
HLB2090TV, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 90A, 50°C, suitable for 400A- LB,HLB standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price