1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
8539SFW44V01H10
8539SFW44V01H10
Square D - Motor Starter
8539SFW44V01H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 4, requires 3 thermal units, supplied with MAG-GARD KAL36250-29M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 50 HP @ 240V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price
In Stock
KA2090T
KA2090T
Westinghouse - Trip Units And Programmers
KA2090T, Westinghouse, KA Series, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 90A, suitable for 225A- KA,HKA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From $393.22
Limited Stock
MP12H2-3P-1000A-EO-BO-LSG
MP12H2-3P-1000A-EO-BO-LSG
Merlin Gerin - Insulated Case
MP12H2-3P-1000A-EO-BO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1200A frame, includes 1200A sensor rating with 1000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
M4RRG2000
M4RRG2000
Cutler Hammer - Rating Plug
M4RRG2000, Cutler Hammer, Magnum DS, rating plug, field installable kit for changing the sensor/rating plug rating on fixed or drawout circuit breakers, includes 1 rating plug plus 8 sensors for 4 pole breakers, rated for 2000A, suitable for use with double frame MDS air circuit breaker frame types, for use with Digitrip 220,520,520M,520MC,1150 solid state programmers
From Get Price
Limited Stock
8539SFA54V06H30
8539SFA54V06H30
Square D - Motor Starter
8539SFA54V06H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 4, requires 3 thermal units, supplied with MAG-GARD KAL36250-29M circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 100 HP @ 480V, complete with 480V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price
Limited Stock
449D701G08
449D701G08
Eaton - Metering
449D701G08 / <strong>3A73103G11</strong>, Cutler Hammer, Eaton, Westinghouse, Cutler Hammer, Eaton, Westinghouse, DS Series, Metering Current Transformer 1200/5, RCT-1600, DSM-16, qty 3 required per breaker, suitable for use with DS-206, DSL-206, DS-206S, DS-206E, DS-416, DSL-416, DS-416H, DS-416S, DS-420, DSII-308, DSII-516, DSII-620 low voltage power air breakers
From Get Price
Limited Stock
HKB2090TA
HKB2090TA
Westinghouse - Trip Units And Programmers
HKB2090TA, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 90A, 50°C, suitable for 250A- KB,HKB standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price
In Stock
S133C
S133C
Square D - Trip Units And Programmers
S133C, Schneider Electric, Merlin Gerin, Square D, Micrologic, field installable Micrologic standard 5.0 trip unit with LSI - Long-Time, Short-Time and Instantaneous trip functions, with type 'C' rating plug, suitable for NS,NT,NW,PG,PJ,PK,PL,RG,RJ,RK,RL molded case & insulated case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From $1,612.58
Limited Stock
PKA36080U64AE1AB
PKA36080U64AE1AB
Schneider Electric - Molded Case
PKA36080U64AE1AB, Square D, Schneider Electric, PowerPact, type , 3P, ABC phase connection, 3PH, 800A, 600V, 50kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, complete with 2A/2B auxiliary switch, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breaker
From Get Price
Limited Stock
MP08-3P-125A-EO-DO-LIG
MP08-3P-125A-EO-DO-LIG
Merlin Gerin - Insulated Case
MP08-3P-125A-EO-DO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 800A frame with 250A trip and 125A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
In Stock
HMA3225T
HMA3225T
Westinghouse - Trip Units And Programmers
HMA3225T, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 225A, suitable for 800A- MA,HMA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From $525.38
Limited Stock
ECN2224EAF-E3
ECN2224EAF-E3
Cutler Hammer - Motor Starter
ECN2224EAF-E3, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP, type , 3P, 3PH, 10 HP @ 200V, 600V, complete with 208V coil, NEMA size 2, 50A HMCP circuit breaker enclosed in oversize NEMA Type 4X 304-grade watertight & dust-tight stainless steel enclosure without control transformer, suitable for use with Freedom Series motor control systems
From Get Price
Limited Stock
8539SHW43V08H30
8539SHW43V08H30
Square D - Motor Starter
8539SHW43V08H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD LAL36400-36M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 100 HP @ 208V, complete with 208V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price
Limited Stock
MP08-3P-150A-MO-DO-LI
MP08-3P-150A-MO-DO-LI
Merlin Gerin - Insulated Case
MP08-3P-150A-MO-DO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 800A frame with 250A trip and 150A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
PB28000TM
PB28000TM
Westinghouse - Trip Units And Programmers
PB28000TM, Westinghouse, PB Series, type , interchangeable trip unit with I - Instantaneous trip functions, front adjustable, rear connected, rated for 2000A, suitable for PB,PA 2500A molded case circuit breaker frame types, magnetic trip range 3000-8000A, Magnetic Only trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
Limited Stock
M3NRG1000
M3NRG1000
Cutler Hammer - Rating Plug
M3NRG1000, Cutler Hammer, Magnum DS, rating plug, field installable kit for changing the sensor/rating plug rating on fixed or drawout circuit breakers, includes 1 rating plug plus 3 sensors for 3 pole breakers, rated for 1000A, suitable for use with narrow frame MDN air circuit breaker frame types, for use with Digitrip 220,520,520M,520MC,1150 solid state programmers
From Get Price
Limited Stock
8539SGW45V07H30
8539SGW45V07H30
Square D - Motor Starter
8539SGW45V07H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 5, requires 3 thermal units, supplied with MAG-GARD LAL36400-33M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 75 HP @ 208V, complete with 600V 60Hz/550V 50Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price
Limited Stock
MA2175TV
MA2175TV
Westinghouse - Trip Units And Programmers
MA2175TV, Westinghouse, MA Series, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 175A, 50°C, suitable for 800A- MA,HMA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
In Stock
HKA2100T
HKA2100T
Westinghouse - Trip Units And Programmers
HKA2100T, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 100A, suitable for 225A- KA,HKA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From $274.82
Limited Stock
MP30H-3P-3000A-MO-BO-LS
MP30H-3P-3000A-MO-BO-LS
Merlin Gerin - Insulated Case
MP30H-3P-3000A-MO-BO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3000A frame, includes 3000A sensor rating with 3000A rating plug, 3P, 3PH, 600V, 75kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP40-3P-4000A-EO-DO-LSG
MP40-3P-4000A-EO-DO-LSG
Merlin Gerin - Insulated Case
MP40-3P-4000A-EO-DO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 4000A frame includes 4000A sensor rating with 4000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
HMA2125TV
HMA2125TV
Westinghouse - Trip Units And Programmers
HMA2125TV, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 125A, 50°C, suitable for 800A- MA,HMA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
Limited Stock
MP20H-3P-2000A-MO-BO-LSIG
MP20H-3P-2000A-MO-BO-LSIG
Merlin Gerin - Insulated Case
MP20H-3P-2000A-MO-BO-LSIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2000A frame, includes 2000A sensor rating with 2000A rating plug, 3P, 3PH, 600V, 75kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
HLB2090TV
HLB2090TV
Westinghouse - Trip Units And Programmers
HLB2090TV, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 90A, 50°C, suitable for 400A- LB,HLB standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price