1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
MP30H-3P-3000A-EO-BO-LSI
MP30H-3P-3000A-EO-BO-LSI
Merlin Gerin - Insulated Case
MP30H-3P-3000A-EO-BO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3000A frame, includes 3000A sensor rating with 3000A rating plug, 3P, 3PH, 600V, 75kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
8539SCA54V01
8539SCA54V01
Square D - Motor Starter
8539SCA54V01, Square D, Class 8539, combination non-reversing motor starter, NEMA size 1, requires 3 thermal units, supplied with MAG-GARD GJL36030-M04 circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 5- 7 1/2 HP @ 240V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems
From Get Price
Limited Stock
AKRT-8A-50-MO-DO-LSG
AKRT-8A-50-MO-DO-LSG
General Electric - Air
AKRT-8A-50-MO-DO-LSG, General Electric, Manually Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 2000A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with Epic MicroVersa Trip Solid State Overcurrent Protection, LSG - Long-Time, Short-Time and Ground Fault trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
Limited Stock
HLB2225TA
HLB2225TA
Westinghouse - Trip Units And Programmers
HLB2225TA, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 225A, 50°C, suitable for 400A- LB,HLB standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price
Limited Stock
AKRU-6D-50-MO-DO-LI
AKRU-6D-50-MO-DO-LI
General Electric - Air
AKRU-6D-50-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage Fused air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with MicroVersa Trip Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor, Rating Plug and Fuse Amperages available
From Get Price
Limited Stock
8539SJA43V01H30
8539SJA43V01H30
Square D - Motor Starter
8539SJA43V01H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 7, requires 3 thermal units, supplied with MAG-GARD MAL361000-47M circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 250-300 HP @ 240V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price
Limited Stock
MP40-3P-4000A-EO-DO-LIG
MP40-3P-4000A-EO-DO-LIG
Merlin Gerin - Insulated Case
MP40-3P-4000A-EO-DO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 4000A frame includes 4000A sensor rating with 4000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
PKA36025U64AE1YP
PKA36025U64AE1YP
Square D - Molded Case
PKA36025U64AE1YP, Schneider Electric, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 250A, 600V, 50kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, complete with fixed handle padlocking device, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breaker
From Get Price
Limited Stock
MP30H-3P-3000A-MO-BO-LIG
MP30H-3P-3000A-MO-BO-LIG
Merlin Gerin - Insulated Case
MP30H-3P-3000A-MO-BO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3000A frame, includes 3000A sensor rating with 3000A rating plug, 3P, 3PH, 600V, 75kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP20-3P-2000A-EO-DO-LS
MP20-3P-2000A-EO-DO-LS
Merlin Gerin - Insulated Case
MP20-3P-2000A-EO-DO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2000A frame includes 2000A sensor rating with 2000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
8539SDW52V01H10
8539SDW52V01H10
Square D - Motor Starter
8539SDW52V01H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 2, requires 3 thermal units, supplied with MAG-GARD GJL36030-M04 circuit breaker and NEMA type 4X enclosure, 3P, 3PH, 600V, 5-7 1/2 HP @ 240V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price
Limited Stock
MP20H-3P-2000A-MO-DO-LS
MP20H-3P-2000A-MO-DO-LS
Merlin Gerin - Insulated Case
MP20H-3P-2000A-MO-DO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2000A frame, includes 2000A sensor rating with 2000A rating plug, 3P, 3PH, 600V, 75kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
8539SJA43V04H30
8539SJA43V04H30
Square D - Motor Starter
8539SJA43V04H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 7, requires 3 thermal units, supplied with MAG-GARD MAL361000-47M circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 250-300 HP @ 240V, complete with 277V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price
Limited Stock
MP12H2-3P-1200A-EO-DO-LS
MP12H2-3P-1200A-EO-DO-LS
Merlin Gerin - Insulated Case
MP12H2-3P-1200A-EO-DO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1200A frame, includes 1200A sensor rating with 1200A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
HMA2300TV
HMA2300TV
Westinghouse - Trip Units And Programmers
HMA2300TV, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 300A, 50°C, suitable for 800A- MA,HMA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
Limited Stock
XT4HQ3040LFF000XXX
XT4HQ3040LFF000XXX
ABB - Molded Case
XT4HQ3040LFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 3-Pole, 40A, 600V, 25kA@600V, Ekip M-LIU (Electronic Motor Protector with integrated overload and phase loss detection), UL 100% Rated, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No - 1SDA07211R1 global reference
From Get Price
Limited Stock
HLA2200TV
HLA2200TV
Westinghouse - Trip Units And Programmers
HLA2200TV, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 200A, 50°C, suitable for 400A- LA,HLA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price
Limited Stock
MP20H2-3P-2000A-EO-BO-LSG
MP20H2-3P-2000A-EO-BO-LSG
Merlin Gerin - Insulated Case
MP20H2-3P-2000A-EO-BO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2000A frame, includes 2000A sensor rating with 2000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
8539SHA43V01H10
8539SHA43V01H10
Square D - Motor Starter
8539SHA43V01H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD LAL36400-36M circuit breaker and NEMA type 12/3R without external reset enclosure, 3P, 3PH, 600V, 250 HP @ 480V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price
Limited Stock
8539SHW46V08H20
8539SHW46V08H20
Square D - Motor Starter
8539SHW46V08H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD MAL36600-44M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 200 HP @ 240V, complete with 208V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price
Limited Stock
8539SGA45V01H10
8539SGA45V01H10
Square D - Motor Starter
8539SGA45V01H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 5, requires 3 thermal units, supplied with MAG-GARD LAL36400-33M circuit breaker and NEMA type 12/3R without external reset enclosure, 3P, 3PH, 600V, 75 HP @ 208V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price
Limited Stock
PJA36080U64AE1AB
PJA36080U64AE1AB
Schneider Electric - Molded Case
PJA36080U64AE1AB, Square D, Schneider Electric, PowerPact, type , 3P, ABC phase connection, 3PH, 800A, 600V, 65kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, complete with 2A/2B auxiliary switch, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breaker
From Get Price
Limited Stock
MP32-3P-3200A-MO-BO-LS
MP32-3P-3200A-MO-BO-LS
Merlin Gerin - Insulated Case
MP32-3P-3200A-MO-BO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3200A frame includes 3200A sensor rating with 3200A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
AKRU-7D-30H-MO-DO-LI
AKRU-7D-30H-MO-DO-LI
General Electric - Air
AKRU-7D-30H-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage Fused air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with MicroVersa Trip RMS-9 Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor, Rating Plug and Fuse Amperages available
From Get Price