


- Home /
15 amp breaker
97,864 Results
Refine Results
In Stock
Subcategory
SORT BY

ECN2218CAC-E3
Cutler Hammer - Motor Starter
ECN2218CAC-E3, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP, type , 3P, 3PH, 2 HP @ 460V, 600V, complete with 480V coil, NEMA size 1, 7A HMCP circuit breaker enclosed in oversize NEMA Type 12 dust-tight industrial enclosure with external reset, without control transformer, suitable for use with Freedom Series motor control systems
From Get Price

MP08-3P-800A-EO-DO-LSIG
Merlin Gerin - Insulated Case
MP08-3P-800A-EO-DO-LSIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 800A frame, includes 800A sensor rating with 800A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP16-3P-800A-EO-BO-LIG
Merlin Gerin - Insulated Case
MP16-3P-800A-EO-BO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1600A frame with 1600A sensor rating with 800A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP20H2-3P-2000A-EO-BO-LI
Merlin Gerin - Insulated Case
MP20H2-3P-2000A-EO-BO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2000A frame, includes 2000A sensor rating with 2000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

M131A
Schneider Electric - Trip Units And Programmers
M131A, Square D, Schneider Electric, Merlin Gerin, Micrologic, field installable, S131A, Micrologic standard 3.0 trip unit with LI - Long-Time and Instantaneous trip functions, with type 'A' rating plug, suitable for NS,NT,NW,PG,PJ,PK,PL,RG,RJ,RK,RL molded case & insulated case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From $538.28

M4RRG5000
Cutler Hammer - Rating Plug
M4RRG5000, Cutler Hammer, Magnum DS, rating plug, field installable kit for changing the sensor/rating plug rating on fixed or drawout circuit breakers, includes 1 rating plug plus 8 sensors for 4 pole breakers, rated for 5000A, suitable for use with double frame MDS air circuit breaker frame types, for use with Digitrip 220,520,520M,520MC,1150 solid state programmers
From Get Price

MP32-3P-3200A-MO-DO-LSG
Merlin Gerin - Insulated Case
MP32-3P-3200A-MO-DO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3200A frame includes 3200A sensor rating with 3200A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP32-3P-3000A-EO-BO-LS
Merlin Gerin - Insulated Case
MP32-3P-3000A-EO-BO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3200A frame includes 3000A, 3200A sensor rating with 3000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

ECN2438DA9
Cutler Hammer - Motor Starter
ECN2438DA9, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP and CPT (control power transformers), type , 3P, 3PH, 30 HP @ 575V, 600V, complete with 600V coil, NEMA size 3, 50A HMCP circuit breaker enclosed in NEMA Type 12 dust-tight industrial enclosure with external reset, suitable for use with Freedom Series motor control systems
From Get Price

MP30H-3P-3000A-EO-BO-LI
Merlin Gerin - Insulated Case
MP30H-3P-3000A-EO-BO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3000A frame, includes 3000A sensor rating with 3000A rating plug, 3P, 3PH, 600V, 75kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

PJA36100U64AE1RE10
Schneider Electric - Molded Case
PJA36100U64AE1RE10, Schneider Electric, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 1000A, 600V, 65kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, complete with door mounted standard black handle, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breaker
From Get Price

LA3200TV
Westinghouse - Trip Units And Programmers
LA3200TV, Westinghouse, LA Series, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 200A, 50°C, suitable for 400A- LA,HLA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price

PJA36100U64AE1AC
Schneider Electric - Molded Case
PJA36100U64AE1AC, Schneider Electric, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 1000A, 600V, 65kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, complete with 3A/3B auxiliary switch, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breaker
From Get Price

MP16H-3P-1600A-EO-BO-LI
Merlin Gerin - Insulated Case
MP16H-3P-1600A-EO-BO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1600A frame, includes 1600A sensor rating and 1600A rating plug, 3P, 3PH, 600V, 65kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP32-3P-3200A-EO-DO-LSI
Merlin Gerin - Insulated Case
MP32-3P-3200A-EO-DO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3200A frame includes 3200A sensor rating with 3200A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP08-3P-250A-EO-DO-LSG
Merlin Gerin - Insulated Case
MP08-3P-250A-EO-DO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 800A frame with 250A or 400A sensor rating and 250A rating plug, 3P, 3PH, 600V, 50kA@480V, available with STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP trip units, Solid State electronic, insulated case circuit breakers
From Get Price

MP50-3P-5000A-EO-BO-LIG
Merlin Gerin - Insulated Case
MP50-3P-5000A-EO-BO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 5000A frame includes 5000A sensor rating with 5000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

8539SFW44V07H10
Square D - Motor Starter
8539SFW44V07H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 4, requires 3 thermal units, supplied with MAG-GARD KAL36250-29M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 50 HP @ 240V, complete with 600V 60Hz/550V 50Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price

8539SDG43V04H30
Square D - Motor Starter
8539SDG43V04H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 2, requires 3 thermal units, supplied with MAG-GARD GJL36050-M05 circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 10 HP @ 240V, complete with 277V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price

8539SDA41V08
Square D - Motor Starter
8539SDA41V08, Square D, Class 8539, combination non-reversing motor starter, NEMA size 2, requires 3 thermal units, supplied with MAG-GARD GJL36015-M03 circuit breaker and NEMA type 12/3R without external reset enclosure, 3P, 3PH, 600V, 1 1/2- 3 HP @ 208V, complete with 208V coil, suitable for use with Class 8539 motor control systems
From Get Price

8539SHG45V04H30
Square D - Motor Starter
8539SHG45V04H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD MAL36600-42M circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 350 HP @ 480V, complete with 277V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price

MP20H2-3P-1000A
Merlin Gerin - Insulated Case
MP20H2-3P-1000A, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2000A frame, includes 1200A, 1600A or 2000A sensor rating with 1000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

8539SCW45V01H10
Square D - Motor Starter
8539SCW45V01H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 1, requires 3 thermal units, supplied with MAG-GARD GJL36050-M05 circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 7 1/2 HP @ 208V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price

8539SCA42V06
Square D - Motor Starter
8539SCA42V06, Square D, Class 8539, combination non-reversing motor starter, NEMA size 1, requires 3 thermal units, supplied with MAG-GARD GJL36007-M02 circuit breaker and NEMA type 12/3R without external reset enclosure, 3P, 3PH, 600V, 1 1/2-3 HP @ 480V, complete with 480V coil, suitable for use with Class 8539 motor control systems
From Get Price