1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
PB3900PT
PB3900PT
Westinghouse - Trip Units And Programmers
PB3900PT, Cutler Hammer, Eaton, Westinghouse, TRI-PAC, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 900A, suitable for Tri-Pac PB,PA 1200A or 1600A molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
Limited Stock
MP25-3P-2500A-MO-BO-LI
MP25-3P-2500A-MO-BO-LI
Merlin Gerin - Insulated Case
MP25-3P-2500A-MO-BO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2500A frame includes 2500A sensor rating with 2500A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
LN203HANNSNNNDNC
LN203HANNSNNNDNC
Cutler Hammer - Cubicles (Cradles)
LN203HANNSNNNDNC, Cutler Hammer, Magnum DS, cubicles (cradles), narrow cassettes for drawout circuit breakers, cassette standard features include an arc hood, provisions for secondary terminal blocks including wiring, and a cell rejection kit, shutters installed, door escutcheon included, unwired for circuit breaker, suitable for narrow Magnum DS 3-pole 800-1600A MDN frame low voltage air circuit breakers
From Get Price
Limited Stock
HLA3225TA
HLA3225TA
Westinghouse - Trip Units And Programmers
HLA3225TA, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 225A, 50°C, suitable for 400A- LA,HLA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price
Limited Stock
AKR-8F-75-MO-DO-LI
AKR-8F-75-MO-DO-LI
General Electric - Air
AKR-8F-75-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 3200A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with Epic MicroVersa Trip Solid State Overcurrent Protection, LSG - Long-Time, Short-Time and Ground Fault trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
Limited Stock
8539SFW44V01H20
8539SFW44V01H20
Square D - Motor Starter
8539SFW44V01H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 4, requires 3 thermal units, supplied with MAG-GARD KAL36250-29M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 50 HP @ 240V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price
Limited Stock
8539SCG45V04H20
8539SCG45V04H20
Square D - Motor Starter
8539SCG45V04H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 1, requires 3 thermal units, supplied with MAG-GARD GJL36050-M05 circuit breaker and NEMA type 1 enclosure, 3P, 3PH, 600V, 7 1/2 HP @ 208V, complete with 277V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price
Limited Stock
8539SHW43V04H20
8539SHW43V04H20
Square D - Motor Starter
8539SHW43V04H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD LAL36400-36M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 250 HP @ 480V, complete with 277V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price
Limited Stock
8539SEW52V07H30
8539SEW52V07H30
Square D - Motor Starter
8539SEW52V07H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 3, requires 3 thermal units, supplied with MAG-GARD FAL36100-18M circuit breaker and NEMA type 4X enclosure, 3P, 3PH, 600V, 40-50 HP @ 600V, complete with 600V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price
Limited Stock
EC22249AAH
EC22249AAH
Cutler Hammer - Motor Starter
EC22249AAH, Cutler Hammer, A200 Series, combination, non-reversing motor starter with HMCP, type , 3P, 3PH, 40 HP @ 200V, 50 HP @ 230V, 100 HP @ 460V, 100 HP @ 575V, 600V, complete with 120V coil, NEMA size 4, 150A HMCP circuit breaker enclosed in NEMA Type 4X 316 grade stainless steel enclosure, suitable for use with A200 Series motor control systems
From Get Price
Limited Stock
8539SCA52V07
8539SCA52V07
Square D - Motor Starter
8539SCA52V07, Square D, Class 8539, combination non-reversing motor starter, NEMA size 1, requires 3 thermal units, supplied with MAG-GARD GJL36007-M02 circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 1 1/2-3 HP @ 600V, complete with 600V coil, suitable for use with Class 8539 motor control systems
From Get Price
In Stock
KB2200T
KB2200T
Westinghouse - Trip Units And Programmers
KB2200T, Westinghouse, AB DE-ION, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 200A, suitable for 250A- KB,HKB standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From $351.83
Limited Stock
8539SGW45V06H10
8539SGW45V06H10
Square D - Motor Starter
8539SGW45V06H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 5, requires 3 thermal units, supplied with MAG-GARD LAL36400-33M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 75 HP @ 208V, complete with 480V 60Hz/440V 50Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price
Limited Stock
MP16H-3P-1600A-EO-BO-LIG
MP16H-3P-1600A-EO-BO-LIG
Merlin Gerin - Insulated Case
MP16H-3P-1600A-EO-BO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1600A frame, includes 1600A sensor rating and 1600A rating plug, 3P, 3PH, 600V, 65kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
8539SCW55V02H10
8539SCW55V02H10
Square D - Motor Starter
8539SCW55V02H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 1, requires 3 thermal units, supplied with MAG-GARD GJL36050-M05 circuit breaker and NEMA type 4X enclosure, 3P, 3PH, 600V, 7 1/2 HP @ 208V, complete with 120V 60Hz/110V 50Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price
Limited Stock
XT2VQ3060LFF000XXX
XT2VQ3060LFF000XXX
ABB - Molded Case
XT2VQ3060LFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 3-Pole, 60A, 600V, 42kA@600V, Ekip M-LIU (Electronic Motor Protector with integrated overload and phase loss detection), UL 100% Rated, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No - 1SDA07211R1 global reference
From Get Price
Limited Stock
M4RRG4000
M4RRG4000
Cutler Hammer - Rating Plug
M4RRG4000, Cutler Hammer, Magnum DS, rating plug, field installable kit for changing the sensor/rating plug rating on fixed or drawout circuit breakers, includes 1 rating plug plus 8 sensors for 4 pole breakers, rated for 4000A, suitable for use with double frame MDS air circuit breaker frame types, for use with Digitrip 220,520,520M,520MC,1150 solid state programmers
From Get Price
In Stock
2603D46G27
2603D46G27
Westinghouse - Trip Units And Programmers
2603D46G27, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 300A, suitable for 600A- LA,HLA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From $1,148.76
Limited Stock
ECN24A8BAC
ECN24A8BAC
Cutler Hammer - Motor Starter
ECN24A8BAC, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP and CPT (control power transformers), type , 3P, 3PH, 1.5 HP @ 230V, 600V, complete with 240V coil, NEMA size 00, 7A HMCP circuit breaker enclosed in NEMA Type 12 dust-tight industrial enclosure with external reset, suitable for use with Freedom Series motor control systems
From Get Price
Limited Stock
MP20H2-3P-2000A-EO-DO-LIG
MP20H2-3P-2000A-EO-DO-LIG
Merlin Gerin - Insulated Case
MP20H2-3P-2000A-EO-DO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2000A frame, includes 2000A sensor rating with 2000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
AKRU-7A-50-MO-DO-LI
AKRU-7A-50-MO-DO-LI
General Electric - Air
AKRU-7A-50-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage Fused air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with MicroVersa Trip RMS-9 Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor, Rating Plug and Fuse Amperages available
From Get Price
Limited Stock
MP12H2-3P-1200A-MO-DO-LI
MP12H2-3P-1200A-MO-DO-LI
Merlin Gerin - Insulated Case
MP12H2-3P-1200A-MO-DO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1200A frame, includes 1200A sensor rating with 1200A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
8539SJW43V02H20
8539SJW43V02H20
Square D - Motor Starter
8539SJW43V02H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 7, requires 3 thermal units, supplied with MAG-GARD MAL361000-47M circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 300 HP @ 240V, complete with 120V 60Hz/110V 50Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price
Limited Stock
8539SDW42V01H20
8539SDW42V01H20
Square D - Motor Starter
8539SDW42V01H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 2, requires 3 thermal units, supplied with MAG-GARD GJL36030-M04 circuit breaker and NEMA type 4 & 4X enclosure, 3P, 3PH, 600V, 5- 7 1/2 HP @ 240V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20