Limited Stock
MP32H-3P-3000A-MO-BO-LS
MP32H-3P-3000A-MO-BO-LS
Merlin Gerin - Insulated Case
MP32H-3P-3000A-MO-BO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3200A frame, includes 3000A or 3200A sensor rating with 3000A rating plug, 3P, 3PH, 600V, 75kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
8539SDA52V01H10
8539SDA52V01H10
Square D - Motor Starter
8539SDA52V01H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 2, requires 3 thermal units, supplied with MAG-GARD GJL36030-M04 circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 5-7 1/2 HP @ 240V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price
Limited Stock
CR306GXQ605
CR306GXQ605
General Electric - Motor Starter
CR306GXQ605, General Electric, 300 Line, type , 3P, 3PH, 270A, 600V, 200 hp, complete with 575V-600V 50/60Hz, AC coil, non-reversing, non-combination magnetic starter, NEMA size 5, includes NEMA type 3R surface mount enclosure, equipped with overload rely to provide 130.0-270.0A with 600 max fuse rating, 800 max breaker rating, suitable for use with CR306 motor control systems
From Get Price
Limited Stock
8539SHA56V07H10
8539SHA56V07H10
Square D - Motor Starter
8539SHA56V07H10, Square D, Class 8539, combination non-reversing motor starter, NEMA size 6, requires 3 thermal units, supplied with MAG-GARD MAL36600-44M circuit breaker and NEMA type 12/3R with external reset enclosure, 3P, 3PH, 600V, 200 HP @ 240V, complete with 600V 60Hz/550V 50Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10
From Get Price
Limited Stock
8539SCA45V01H20
8539SCA45V01H20
Square D - Motor Starter
8539SCA45V01H20, Square D, Class 8539, combination non-reversing motor starter, NEMA size 1, requires 3 thermal units, supplied with MAG-GARD GJL36050-M05 circuit breaker and NEMA type 12/3R without external reset enclosure, 3P, 3PH, 600V, 7 1/2 HP @ 208V, complete with 24V 60Hz coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 20
From Get Price
Limited Stock
MP25H2-3P-1200A-EO-BO-LSIG
MP25H2-3P-1200A-EO-BO-LSIG
Merlin Gerin - Insulated Case
MP25H2-3P-1200A-EO-BO-LSIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2500A frame, includes 1200A, 1600A, 2000A or 2500A sensor rating with 1200A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP16H2-3P-1200A-MO-BO-LI
MP16H2-3P-1200A-MO-BO-LI
Merlin Gerin - Insulated Case
MP16H2-3P-1200A-MO-BO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1600A frame, includes 1200A or 1600A sensor rating with 1200A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP40H-3P-3000A-EO-DO-LSIG
MP40H-3P-3000A-EO-DO-LSIG
Merlin Gerin - Insulated Case
MP40H-3P-3000A-EO-DO-LSIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 4000A frame, includes 3000A, 3200A or 4000A sensor rating with 3000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP16H2-3P-1000A-MO-BO-LIG
MP16H2-3P-1000A-MO-BO-LIG
Merlin Gerin - Insulated Case
MP16H2-3P-1000A-MO-BO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1600A frame, includes 1200A or 1600A sensor rating with 1000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
CR306EXM105
CR306EXM105
General Electric - Motor Starter
CR306EXM105, General Electric, 300 Line, type , 3P, 3PH, 90A, 600V, 50 hp, complete with 575V-600V 50/60Hz, AC coil, non-reversing, non-combination magnetic starter, NEMA size 3, includes NEMA type 1 surface mount enclosure, equipped with overload rely to provide 65.0-135.0A with 500 max fuse rating, 400 max breaker rating, suitable for use with CR306 motor control systems
From Get Price
Limited Stock
MP25H-3P-1600A-EO-BO-LIG
MP25H-3P-1600A-EO-BO-LIG
Merlin Gerin - Insulated Case
MP25H-3P-1600A-EO-BO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2500A frame, includes 1600A, 2000A or 2500A sensor rating with 1600A rating plug, 3P, 3PH, 600V, 75kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
KB2250TA
KB2250TA
Westinghouse - Trip Units And Programmers
KB2250TA, Westinghouse, AB DE-ION, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 250A, 50°C, suitable for 250A- KB,HKB standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price
Limited Stock
BD3050D
BD3050D
Cutler Hammer - Molded Case
BD3050D, Cutler Hammer, BD Series, type duplex, 2P, 1PH, 30/50A, 120V, 10kA@120V, standard interrupting capacity, Feed-Thru, HACR rated, UL type BRD, install breaker only in panel positions that have dented bus stabs, complete with rejection tab feature, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
MP08H-3P-600A-EO-BO-LS
MP08H-3P-600A-EO-BO-LS
Merlin Gerin - Insulated Case
MP08H-3P-600A-EO-BO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 800A frame, includes 600A or 800A sensor rating with 600A rating plug, 3P, 3PH, 600V, 65kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP trip units, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP40-3P-3000A-EO-BO-LS
MP40-3P-3000A-EO-BO-LS
Merlin Gerin - Insulated Case
MP40-3P-3000A-EO-BO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 4000A frame includes 3000A, 3200A or 4000A sensor rating with 3000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP25-3P-2000A-MO-BO-LSG
MP25-3P-2000A-MO-BO-LSG
Merlin Gerin - Insulated Case
MP25-3P-2000A-MO-BO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2500A frame includes 2000A or 2500A sensor rating with 2000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
KB2100TV
KB2100TV
Westinghouse - Trip Units And Programmers
KB2100TV, Westinghouse, AB DE-ION, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 100A, 50°C, suitable for 250A- KB,HKB standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price
Limited Stock
MP63H-3P-3200A-MO-BO-LIG
MP63H-3P-3200A-MO-BO-LIG
Merlin Gerin - Insulated Case
MP63H-3P-3200A-MO-BO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 6300A frame, includes 3200A, 4000A, 5000A, or 6300A sensor rating with 3200A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP20-3P-1600A-EO-BO-LSI
MP20-3P-1600A-EO-BO-LSI
Merlin Gerin - Insulated Case
MP20-3P-1600A-EO-BO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2000A frame includes 1600A or 2000A sensor rating with 1600A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
CR306DXH405
CR306DXH405
General Electric - Motor Starter
CR306DXH405, General Electric, 300 Line, type , 3P, 3PH, 45A, 600V, 25 hp, complete with 575V-600V 50/60Hz, AC coil, non-reversing, non-combination magnetic starter, NEMA size 2, includes NEMA type 4/4X surface mount enclosure, equipped with overload rely to provide 13.0-27.0A with 100 max fuse rating, 100 max breaker rating, suitable for use with CR306 motor control systems
From Get Price
Limited Stock
MP25H-3P-2000A-EO-DO-LSI
MP25H-3P-2000A-EO-DO-LSI
Merlin Gerin - Insulated Case
MP25H-3P-2000A-EO-DO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2500A frame, includes 2000A or 2500A sensor rating with 2000A rating plug, 3P, 3PH, 600V, 75kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP16H2-3P-1000A-EO-BO-LSIG
MP16H2-3P-1000A-EO-BO-LSIG
Merlin Gerin - Insulated Case
MP16H2-3P-1000A-EO-BO-LSIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1600A frame, includes 1200A or 1600A sensor rating with 1000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP50-3P-2500A-MO-BO-LSG
MP50-3P-2500A-MO-BO-LSG
Merlin Gerin - Insulated Case
MP50-3P-2500A-MO-BO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 5000A frame includes 2500A, 3000A, 3200A, 4000A or 5000A sensor rating with 2500A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
8539SDA43V08H30
8539SDA43V08H30
Square D - Motor Starter
8539SDA43V08H30, Square D, Class 8539, combination non-reversing motor starter, NEMA size 2, requires 3 thermal units, supplied with MAG-GARD GJL36050-M05 circuit breaker and NEMA type 12/3R without external reset enclosure, 3P, 3PH, 600V, 7 1/2-10 HP @ 208V, complete with 208V coil, suitable for use with Class 8539 motor control systems, Motor Logic SSOLR Class 10/20
From Get Price