1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
GTD-MC-500-2000A-MO-6P
GTD-MC-500-2000A-MO-6P
Allis Chalmers - Ground & Test Device
GTD-MC-500-2000A-MO-6P, Allis Chalmers, MC Series, , Manually Operated, 3PH, 6 Bushing Design, 15000 VAC, 2000A Frame, circuit breaker ground & test device, For Use In Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price
In Stock
48367
48367
Schneider Electric - Trip Units And Programmers
48367, Schneider Electric, Merlin Gerin, Square D, Micrologic, field installable, S174A Micrologic standard 6.0H trip unit with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, metering, advanced protection & harmonic analysis, with type 'A' rating plug, suitable for - NS,NT,NW,PG,PJ,PK,PL,RG,RJ,RK,RL molded case & insulated case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From $5,470.33
Limited Stock
AKR-11A-30S-EO-DO-LI
AKR-11A-30S-EO-DO-LI
General Electric - Air
AKR-11A-30S-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with EntelliGuard Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
Limited Stock
GTD-AMVAC-1200-2000A-MO-6P
GTD-AMVAC-1200-2000A-MO-6P
ABB - Ground & Test Device
GTD-AMVAC-1200-2000A-MO-6P, ABB, AMVAC Series, , Manually Operated, 3PH, 6 Bushing Design, 15000 VAC, A Frame, circuit breaker ground & test device, For Use In Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price
Limited Stock
CR306FXP403
CR306FXP403
General Electric - Motor Starter
CR306FXP403, General Electric, 300 Line, type , 3P, 3PH, 135A, 600V, 50 hp, complete with 230V-240V 50/60Hz, AC coil, non-reversing, non-combination magnetic starter, NEMA size 4-5, includes NEMA type 4/4X surface mount enclosure, equipped with overload rely to provide 65.0-135.0A with 500 max fuse rating, 400 max breaker rating, suitable for use with CR306 motor control systems
From Get Price
Limited Stock
PVV-3000-10-3000A-MO-6P
PVV-3000-10-3000A-MO-6P
General Electric - Ground & Test Device
PVV-3000-10-3000A-MO-6P, General Electric, PowerVac, , Manually Operated, 3PH, 6 Bushing Design, 15000 VAC, 3000A Frame, circuit breaker ground & test device, For Use In PowerVac Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price
Limited Stock
MDSC303HEA305GAMNN2EMKNAX
MDSC303HEA305GAMNN2EMKNAX
Eaton - Insulated Case
MDSC303HEA305GAMNN2EMKNAX, Cutler Hammer, Eaton, Magnum DS Type , Standard frame, 100kA@635V interrupting rating, 3000A, 3-Pole, Fixed horizonal mounting, 3000A rating plug, Non-DSL current limiter, 520 LSIG trip unit, 110-127 Vac/Vdc shunt trip, Manual operated motor operator, No SRD, No, 2A/2B auxiliary switch, Metal (block close and open) padlock, No counter - Kirk lock key lock, low voltage power insulated case circuit breaker
From Get Price
Limited Stock
AKJ-4A-50H-EO-DO-LI
AKJ-4A-50H-EO-DO-LI
General Electric - Air
AKJ-4A-50H-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKJ Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAV}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with SST Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
Limited Stock
Q2MH2200
Q2MH2200
Square D - Molded Case
Q2MH2200, Square D, Q2 Series, type , 2P, 1PH, 200A, 120/240V, 42kA@240V, UL listed, very high interrupting capacity, Bolt-On, bottom mounted, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, suitable for use as main circuit breaker, Thermal Magnetic, molded case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
Q2M2225MTH
Q2M2225MTH
Square D - Molded Case
Q2M2225MTH, Square D, Q2 Series, type , 2P, 1PH, 225A, 120/240V, 22kA@240V, UL listed, high interrupting capacity, Bolt-On, top mounted, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, suitable for use as main circuit breaker, Thermal Magnetic, molded case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
In Stock
S174D
S174D
Merlin Gerin - Trip Units And Programmers
S174D, Square D, Merlin Gerin, Schneider Electric, Micrologic, field installable Micrologic standard 6.0H trip unit, features LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, metering, advanced protection & harmonic analysis, with type 'D' rating plug, suitable for use with NS,NT,NW,PG,PJ,PK,PL,RG,RJ,RK,RL molded case & insulated case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From $1,962.44
In Stock
47293
47293
Merlin Gerin - Trip Units And Programmers
47293, Schneider Electric, Square D, Merlin Gerin, Micrologic, field installable, S173A, Micrologic standard 5.0H trip unit with LSI - Long-Time, Short-Time and Instantaneous trip functions, metering, advanced protection & harmonic analysis, with type 'A' rating plug, suitable for - NS,NT,NW,PG,PJ,PK,PL,RG,RJ,RK,RL molded case & insulated case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From $3,755.67
Limited Stock
GBHS2020D
GBHS2020D
Cutler Hammer - Molded Case
GBHS2020D, Cutler Hammer, Quicklag, type , not UL listed, 2P, 1PH, 20A, 347/600V, 50/60Hz, 10kA@600V, Bolt-On branch circuit breaker designed for use in 277/480Vac panelboards, includes solenoid-operated mechanism, standard interrupting capacity, 40°C, Bolt-On, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line side lug terminals, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
AKR-11S-30H-EO-BI-LI
AKR-11S-30H-EO-BI-LI
General Electric - Air
AKR-11S-30H-EO-BI-LI, General Electric, Electrically Operated, Bolt-In, Low Voltage air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with EntelliGuard Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
Limited Stock
AKRT-6A-50-EO-DO-LI
AKRT-6A-50-EO-DO-LI
General Electric - Air
AKRT-6A-50-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 2000A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAV}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with MicroVersa Trip Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
Limited Stock
BQ215240RT
BQ215240RT
Cutler Hammer - Molded Case
BQ215240RT, Cutler Hammer, BQ Series, type quadplex independent trip, 2P, 1PH, 15A/40A, 120/240V, 10kA@240V, standard interrupting capacity, Feed-Thru, HACR rated, UL type BRD, install breaker only in panel positions that have notched bus stabs, complete with non-rejection tab feature, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
AKJ-5S-50-EO-BI-LI
AKJ-5S-50-EO-BI-LI
General Electric - Air
AKJ-5S-50-EO-BI-LI, General Electric, Electrically Operated, Bolt-In, Low Voltage air circuit breaker, AKJ Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAV}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with ECS Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
Limited Stock
GTD-VR-1200A-MO-6P
GTD-VR-1200A-MO-6P
Square D - Ground & Test Device
GTD-VR-1200A-MO-6P, Square D, VR Series, , Manually Operated, 3PH, 6 Bushing Design, 27000 VAC, 1200A Frame, circuit breaker ground & test device, For Use In Masterclad Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price
Limited Stock
CR306CXH405
CR306CXH405
General Electric - Motor Starter
CR306CXH405, General Electric, 300 Line, type , 3P, 3PH, 27A, 600V, 10 hp, complete with 575V-600V 50/60Hz, AC coil, non-reversing, non-combination magnetic starter, NEMA size 00-2, includes NEMA type 4/4X surface mount enclosure, equipped with overload rely to provide 13.0-27.0A with 100 max fuse rating, 100 max breaker rating, suitable for use with CR306 motor control systems
From Get Price
Limited Stock
PVV-1200-2000-1200A-MO-6P
PVV-1200-2000-1200A-MO-6P
General Electric - Ground & Test Device
PVV-1200-2000-1200A-MO-6P, General Electric, PowerVac, , Manually Operated, 3PH, 6 Bushing Design, 15000 VAC, 1200A Frame, circuit breaker ground & test device, For Use In PowerVac Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price
Limited Stock
GTD-38-HKV-1200A-EO-6P
GTD-38-HKV-1200A-EO-6P
ITE - Ground & Test Device
GTD-38-HKV-1200A-EO-6P, ITE, HKV Series, , Electrically Operated, 3PH, 6 Bushing Design, 34500 VAC, 1200A Frame, circuit breaker ground & test device, For Use In 38HKV Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price
Limited Stock
GHQRSP2015
GHQRSP2015
Cutler Hammer - Molded Case
GHQRSP2015, Cutler Hammer, Quicklag, type , 2P, 1PH, 15A, 480Y/277, 50/60Hz, 14kA@277V, UL listed, HID rated, Bolt-On branch circuit breaker designed for use in 277/480Vac panelboards, includes solenoid-operated mechanism, standard interrupting capacity, 40°C, Bolt-On, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line side lug terminals, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
GTD-K-600-600A-MO-6P
GTD-K-600-600A-MO-6P
ABB - Ground & Test Device
GTD-K-600-600A-MO-6P, ABB, K-Line Series, , Manually Operated, 3PH, 6 Bushing Design, 600 VAC, 600A Frame, circuit breaker ground & test device, For Use In K-Line Series Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price
Limited Stock
AKR-11A-50-EO-DO-LI
AKR-11A-50-EO-DO-LI
General Electric - Air
AKR-11A-50-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with EntelliGuard Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price