MDSC083WEA0852NNNN2EPNNAX
Eaton - Insulated Case
MDSC083WEA0852NNNN2EPNNAX, Cutler Hammer, Eaton, Magnum DS Type , Standard frame, 100kA@635V interrupting rating, 800A, 3-Pole, Drawout mounting, 800A rating plug, Non-DSL current limiter, 520 LSI trip unit, No shunt trip, 110-125 Vac (5-sec) motor operator, No SRD, No, 2A/2B auxiliary switch, Plastic (block close and open) padlock, No counter - no lock key lock, low voltage power insulated case circuit breaker
From Get Price

AKR-4B-30-EO-DO-LI
General Electric - Air
AKR-4B-30-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with SST Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

0209B8104G007
General Electric - Control Part
0209B8104G007 / <strong>0282A7015G011</strong>, General Electric, General Electric, PowerVac, Trip Coil *Single & Dual*, 250VDC (3 Cycle) & 125 VDC (1st Coil 5 Cycle), VB-1 0,1,2,3, ML-18, qty 1 needed per breaker, suitable for VB1 4.16-250 (1200 & 2000A), VB1 4.16-350 (1200, 2000, 3000A), VB1 7.2-500 (1200 & 2000A), VB1 13.8-500 (1200 & 2000A), VB1 13.8-750 (1200 & 2000A), VB1 13.8-1000 (1200, 2000, 3000A) breakers
From Get Price

CR306FXM423
General Electric - Motor Starter
CR306FXM423, General Electric, 300 Line, type , 3P, 3PH, 135A, 600V, 40 hp, complete with 200V-208V 50/60Hz, AC coil, non-reversing, non-combination magnetic starter, NEMA size 3-4, includes NEMA type 4/4X surface mount enclosure, equipped with overload rely to provide 65.0-135.0A with 500 max fuse rating, 400 max breaker rating, suitable for use with CR306 motor control systems
From Get Price

BQ215215RT
Cutler Hammer - Molded Case
BQ215215RT, Cutler Hammer, BQ Series, type quadplex independent trip, 2P, 1PH, 15A/15A, 120/240V, 10kA@240V, standard interrupting capacity, Feed-Thru, HACR rated, UL type BRD, install breaker only in panel positions that have notched bus stabs, complete with non-rejection tab feature, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic molded case circuit breakers
From Get Price

CR306FXM405
General Electric - Motor Starter
CR306FXM405, General Electric, 300 Line, type , 3P, 3PH, 135A, 600V, 100 hp, complete with 575V-600V 50/60Hz, AC coil, non-reversing, non-combination magnetic starter, NEMA size 3-4, includes NEMA type 4/4X surface mount enclosure, equipped with overload rely to provide 65.0-135.0A with 500 max fuse rating, 400 max breaker rating, suitable for use with CR306 motor control systems
From Get Price

AKR-7D-30H-EO-DO-LI
General Electric - Air
AKR-7D-30H-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with MicroVersa Trip RMS-9 Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

Q2M2175MT
Square D - Molded Case
Q2M2175MT, Square D, Q2 Series, type , 2P, 1PH, 175A, 120/240V, 10kA@240V, UL listed, standard interrupting capacity, Bolt-On, top mounted, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, suitable for use as main circuit breaker, Thermal Magnetic, molded case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

AKJ-5A-50H-EO-DO-LI
General Electric - Air
AKJ-5A-50H-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKJ Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAV}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with ECS Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

GTD-VCP-T-67A3056G02-2000A-MO-6P
Eaton - Ground & Test Device
GTD-VCP-T-67A3056G02-2000A-MO-6P, Eaton, VCP-T Series, , Manually Operated, 3PH, 6 Bushing Design, 15000 VAC, 2000A Frame, circuit breaker ground & test device, For Use In Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price

AKR-7A-30S-EO-DO-LI
General Electric - Air
AKR-7A-30S-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with MicroVersa Trip RMS-9 Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

GL-10M25R-1200A-MO-6P
Toshiba - Ground & Test Device
GL-10M25R-1200A-MO-6P, Toshiba, VK Series, , Manually Operated, 3PH, 6 Bushing Design, 15000 VAC, 1200A Frame, circuit breaker ground & test device, For Use In Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price

AKRU-6D-30H-EO-DO-LI
General Electric - Air
AKRU-6D-30H-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage Fused air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with MicroVersa Trip Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor, Rating Plug and Fuse Amperages available
From Get Price

AKRT-11B-50H-EO-DO-LI
General Electric - Air
AKRT-11B-50H-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 2000A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAV}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with EntelliGuard Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

QCR2015P
Cutler Hammer - Molded Case
QCR2015P, Cutler Hammer, Quicklag, type , 2P, 1PH, 15A, 120/240V, 10kA@240V, standard interrupting capacity, Bolt-On, rear-mounted, UL listed for use as branch circuit protectors, suitable for terminating two 10 AWG Quick-Connect type terminals per phase on breaker load side, complete with trip, LI - Long-Time and Instantaneous trip functions, and load side lug terminals, Thermal Magnetic, molded case miniature industrial circuit breakers
From Get Price

AKR-11B-30H-EO-DO-LI
General Electric - Air
AKR-11B-30H-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with EntelliGuard Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

Q2M2150MTH
Square D - Molded Case
Q2M2150MTH, Square D, Q2 Series, type , 2P, 1PH, 150A, 120/240V, 22kA@240V, UL listed, high interrupting capacity, Bolt-On, top mounted, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, suitable for use as main circuit breaker, Thermal Magnetic, molded case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

AKR-5B-30-EO-DO-LI
General Electric - Air
AKR-5B-30-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with ECS Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

MDS6323WEA32MMAMNNNNMNNAX
Eaton - Insulated Case
MDS6323WEA32MMAMNNNNMNNAX, Cutler Hammer, Eaton, Magnum DS Type , Standard frame, 65kA@635V interrupting rating, 2300A, 3-Pole, Drawout mounting, 3200A rating plug, Non-DSL current limiter, 520M LSIG (120 Vac) trip unit, 110-127 Vac/Vdc shunt trip, Manual operated motor operator, No SRD, No, No auxiliary switch, Metal (block close and open) padlock, No counter - no lock key lock, low voltage power insulated case circuit breaker
From Get Price

AKR-11B-50H-EO-DO-LI
General Electric - Air
AKR-11B-50H-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with EntelliGuard Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

0346A9302G086
General Electric - Control Part
0346A9302G086, General Electric, PowerVac, Stationary Auxiliary Switch Assembly, (MOC Switch) 6A/6B Connect & Test Positions, VB, VB-1 0,1,2,3, ML-17, ML-18, qty 1 needed per breaker, suitable for use with VB1 4.16-250 (1200 & 2000A), VB1 4.16-350 (1200, 2000, 3000A), VB1 7.2-500 (1200 & 2000A), VB1 13.8-500 (1200 & 2000A), VB1 13.8-750 (1200 & 2000A), VB1 13.8-1000 (1200, 2000, 3000A) breakers
From Get Price

CR306CXH404
General Electric - Motor Starter
CR306CXH404, General Electric, 300 Line, type , 3P, 3PH, 27A, 600V, 10 hp, complete with 460V-480V 50/60Hz, AC coil, non-reversing, non-combination magnetic starter, NEMA size 00-2, includes NEMA type 4/4X surface mount enclosure, equipped with overload rely to provide 13.0-27.0A with 100 max fuse rating, 100 max breaker rating, suitable for use with CR306 motor control systems
From Get Price

S163B
Merlin Gerin - Trip Units And Programmers
S163B, Square D, Schneider Electric, Merlin Gerin, Micrologic, field installable Micrologic standard 5.0P trip unit, features LSI - Long-Time, Short-Time and Instantaneous trip functions, comes complete with metering & advanced protection, with type 'B' rating plug, suitable for use with NS,NT,NW,PG,PJ,PK,PL,RG,RJ,RK,RL molded case & insulated case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From $1,842.67

GTD-VCP-692C520G02-1200-2000A-MO-6P
Westinghouse - Ground & Test Device
GTD-VCP-692C520G02-1200-2000A-MO-6P, Westinghouse, VCP Series, , Manually Operated, 3PH, 6 Bushing Design, 15000 VAC, A Frame, circuit breaker ground & test device, For Use In VacClad Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price