SB12TP01
Siemens - Trip Units And Programmers
SB12TP01, Siemens, SB Series, type , Solid State digital electronic interchangeable programmer / trip unit device, complete with LSI - Long-Time, Short-Time and Instantaneous trip functions, rated for 1200A, standard model including real-time voltage and current waveform displays, overcurrent protection, metering and communications, suitable for use with SBA,SBH,SBS insulated case circuit breaker frame types, these trip unit devices are now obsolete; however, we do still stock them
From Get Price

FPS-25-VR-600A-DO
Federal Pacific - Air
FPS-25-VR-600A-DO, Federal Pacific, FPS Series, , 3PH, 3P, 600 VAC, 600 Frame, NA, Draw-Out, Low Voltage air circuit breaker, 15A-600 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

LG-2500-2500A-EO-BO
ITE - Air
LG-2500-2500A-EO-BO, ITE, LG Series, , 3PH, 3P, 600 VAC, 2500 Frame, Electrically Operated, Bolt-On, Low Voltage air circuit breaker, 15A-2500 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

DS-416-1600A-EO-DO
Westinghouse - Air
DS-416-1600A-EO-DO, Westinghouse, DS Series, , 3PH, 3P, 600 VAC, 1600 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-1600 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

KB-125A-MO-BO
ITE - Air
KB-125A-MO-BO, ITE, KB Series, , 3PH, 3P, 600 VAC, 125 Frame, Manually Operated, Bolt-On, Low Voltage air circuit breaker, 15A-125 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

AKR-7A-50-EO-DO-LI
General Electric - Air
AKR-7A-50-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with MicroVersa Trip RMS-9 Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

LK-16-1600A-EO-DO
BBC - Air
LK-16-1600A-EO-DO, BBC, LK Series, , 3PH, 3P, 600 VAC, 1600 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-1600 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

PLM-800-800A-EO-DO
Pennsylvania Switchgear - Air
PLM-800-800A-EO-DO, Pennsylvania Switchgear, PLM Series, , 3PH, 3P, 600 VAC, 800 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-800 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

S164E
Merlin Gerin - Trip Units And Programmers
S164E, Square D, Merlin Gerin, Schneider Electric, Micrologic, field installable Micrologic standard 6.0P trip unit, features LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, comes complete with metering & advanced protection, with type 'E' rating plug, suitable for use with NS,NT,NW,PG,PJ,PK,PL,RG,RJ,RK,RL molded case & insulated case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From $2,625.21

MDS6083WAA03MMAWAN4NNNNAX
Eaton - Insulated Case
MDS6083WAA03MMAWAN4NNNNAX, Cutler Hammer, Eaton, Magnum DS Type , Standard frame, 65kA@635V interrupting rating, 800A, 3-Pole, Drawout mounting, 300A rating plug, Non-DSL current limiter, 520M LSIG (120 Vac) trip unit, 110-127 Vac/Vdc shunt trip, 110-125 Vdc (5-sec) motor operator, 110-127 Vac/Vdc SRD, No, 4A/4B auxiliary switch, No padlock, No counter - no lock key lock, low voltage power insulated case circuit breaker
From Get Price

KB-200A-EO-DO
ITE - Air
KB-200A-EO-DO, ITE, KB Series, , 3PH, 3P, 600 VAC, 200 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-200 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

GM-13.8-1000-1200A-MO-3P
General Electric - Ground & Test Device
GM-13.8-1000-1200A-MO-3P, General Electric, Magne-Blast Series, , Manually Operated, 3PH, 3 Bushing Design, 15000 VAC, 1200A Frame, circuit breaker ground & test device, For Use In M-36H Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price

DS-416-1600A-EO-BO
Westinghouse - Air
DS-416-1600A-EO-BO, Westinghouse, DS Series, , 3PH, 3P, 600 VAC, 1600 Frame, Electrically Operated, Bolt-On, Low Voltage air circuit breaker, 15A-1600 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

GM-7.2-500-1200A-MO-6P
General Electric - Ground & Test Device
GM-7.2-500-1200A-MO-6P, General Electric, Magne-Blast Series, , Manually Operated, 3PH, 6 Bushing Design, 7200 VAC, 1200A Frame, circuit breaker ground & test device, For Use In M-36 Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price

S164G
Merlin Gerin - Trip Units And Programmers
S164G, Square D, Schneider Electric, Merlin Gerin, Micrologic, field installable Micrologic standard 6.0P trip unit, features LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, comes complete with metering & advanced protection, with type 'G' rating plug, suitable for use with NS,NT,NW,PG,PJ,PK,PL,RG,RJ,RK,RL molded case & insulated case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From $2,686.97

AKR-8D-30S-EO-DO-LSG
General Electric - Air
AKR-8D-30S-EO-DO-LSG, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with Epic MicroVersa Trip Solid State Overcurrent Protection, LSG - Long-Time, Short-Time and Ground Fault trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

FP-100-3000A-EO-DO
Federal Pacific - Air
FP-100-3000A-EO-DO, Federal Pacific, FP Series, , 3PH, 3P, 600 VAC, 3000 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-3000 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

GM38T-MAN-1-6-1200-2000A-MO-6P
Siemens - Ground & Test Device
GM38T-MAN-1-6-1200-2000A-MO-6P, Siemens, 3AH3 Series, , Manually Operated, 3PH, 6 Bushing Design, 38000 VAC, A Frame, circuit breaker ground & test device, For Use In Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price

AKR-10B-75-EO-DO-LI
General Electric - Air
AKR-10B-75-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 3200A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with MicroVersa Trip Plus - Gen 2 Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

MDS6323WEA30CMANAN4YNANAX-XDL
Eaton - Insulated Case
MDS6323WEA30CMANAN4YNANAX-XDL, Cutler Hammer, Eaton, Magnum DS Type , Standard frame, 65kA@635V interrupting rating, 2300A, 3-Pole, Drawout mounting, 3000A rating plug, Non-DSL current limiter, 520MC LSIG (120 Vac) trip unit, 110-127 Vac/Vdc shunt trip, 110-125 Vac (5-sec) motor operator, 110-127 Vac/Vdc SRD, No, 4A/4B auxiliary switch, No padlock, Counter - no lock key lock, low voltage power insulated case circuit breaker
From Get Price

AKR-8D-50-EO-DO-LI
General Electric - Air
AKR-8D-50-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with Epic MicroVersa Trip Solid State Overcurrent Protection, LSG - Long-Time, Short-Time and Ground Fault trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

KD-A-3000A-EO-DO
ITE - Air
KD-A-3000A-EO-DO, ITE, KD Series, , 3PH, 3P, 600 VAC, 3000 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-3000 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

KB-250A-EO-DO
ITE - Air
KB-250A-EO-DO, ITE, KB Series, , 3PH, 3P, 600 VAC, 250 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-250 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

AKRU-11D-30-EO-DO-LI
General Electric - Air
AKRU-11D-30-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage Fused air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with EntelliGuard Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor, Rating Plug and Fuse Amperages available
From Get Price