MWI6323LEA3252ANAA6EMNNAX
MWI6323LEA3252ANAA6EMNNAX
Eaton - Air
MWI6323LEA3252ANAA6EMNNAX, Cutler Hammer, Eaton, Magnum IEC Type , Standard frame, 65kV@690V interrupting rating, 3200A, 3-Pole, Drawout Horizontal mounting, 3200 rating plug, {current limiter} current limiter, 520 LSI trip unit, 110-127 Vac/Vdc shunt trip, 110-125 Vac (5-sec) motor operator, 110-127 Vac/Vdc SRD, 6A/6B auxiliary switch, Metal (block close and open) padlock, No counter - no locks key lock, air circuit breaker
From Get Price
Limited Stock
AKR-9A-30-EO-DO-LI
AKR-9A-30-EO-DO-LI
General Electric - Air
AKR-9A-30-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with MicroVersa Trip Plus - Gen 1 Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
Limited Stock
LK-16-1600A-EO-DO
LK-16-1600A-EO-DO
BBC - Air
LK-16-1600A-EO-DO, BBC, LK Series, , 3PH, 3P, 600 VAC, 1600 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-1600 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price
Limited Stock
SB32TP01
SB32TP01
Siemens - Trip Units And Programmers
SB32TP01, Siemens, SB Series, type , Solid State digital electronic interchangeable programmer / trip unit device, complete with LSI - Long-Time, Short-Time and Instantaneous trip functions, rated for 3200A, standard model including real-time voltage and current waveform displays, overcurrent protection, metering and communications, suitable for use with SBA,SBH,SBS insulated case circuit breaker frame types, these trip unit devices are now obsolete; however, we do still stock them
From Get Price
Limited Stock
AKRU-11D-30-EO-DO-LI
AKRU-11D-30-EO-DO-LI
General Electric - Air
AKRU-11D-30-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage Fused air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with EntelliGuard Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor, Rating Plug and Fuse Amperages available
From Get Price
Limited Stock
PLM-800-800A-EO-DO
PLM-800-800A-EO-DO
Pennsylvania Switchgear - Air
PLM-800-800A-EO-DO, Pennsylvania Switchgear, PLM Series, , 3PH, 3P, 600 VAC, 800 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-800 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price
In Stock
S164E
S164E
Merlin Gerin - Trip Units And Programmers
S164E, Square D, Merlin Gerin, Schneider Electric, Micrologic, field installable Micrologic standard 6.0P trip unit, features LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, comes complete with metering & advanced protection, with type 'E' rating plug, suitable for use with NS,NT,NW,PG,PJ,PK,PL,RG,RJ,RK,RL molded case & insulated case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From $2,625.21
Limited Stock
DS-206-600A-EO-DO
DS-206-600A-EO-DO
Westinghouse - Air
DS-206-600A-EO-DO, Westinghouse, DS Series, , 3PH, 3P, 600 VAC, 600 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-600 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price
Limited Stock
GTD-VCP-W-3777A50G02-2000A-EO-3P
GTD-VCP-W-3777A50G02-2000A-EO-3P
Westinghouse - Ground & Test Device
GTD-VCP-W-3777A50G02-2000A-EO-3P, Westinghouse, VCP-W Series, , Electrically Operated, 3PH, 3 Bushing Design, 5000 VAC, 2000A Frame, circuit breaker ground & test device, For Use In VacClad-W Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price
In Stock
S164G
S164G
Merlin Gerin - Trip Units And Programmers
S164G, Square D, Schneider Electric, Merlin Gerin, Micrologic, field installable Micrologic standard 6.0P trip unit, features LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, comes complete with metering & advanced protection, with type 'G' rating plug, suitable for use with NS,NT,NW,PG,PJ,PK,PL,RG,RJ,RK,RL molded case & insulated case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From $2,686.97
In Stock
DSLII-620-2000A-MO-DO
DSLII-620-2000A-MO-DO
Cutler Hammer - Air
DSLII-620-2000A-MO-DO, Cutler Hammer, DSLII Series, , 3PH, 3P, 600 VAC, 2000 Frame, Manually Operated, Draw-Out, Low Voltage air circuit breaker, 15A-2000 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price
Limited Stock
AKR-10A-30-EO-DO-LI
AKR-10A-30-EO-DO-LI
General Electric - Air
AKR-10A-30-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with MicroVersa Trip Plus - Gen 2 Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
Limited Stock
MWI6253LEA2552ANAA6EMNNAX
MWI6253LEA2552ANAA6EMNNAX
Eaton - Air
MWI6253LEA2552ANAA6EMNNAX, Cutler Hammer, Eaton, Magnum IEC Type , Standard frame, 65kV@690V interrupting rating, 2500A, 3-Pole, Drawout Horizontal mounting, 2500 rating plug, {current limiter} current limiter, 520 LSI trip unit, 110-127 Vac/Vdc shunt trip, 110-125 Vac (5-sec) motor operator, 110-127 Vac/Vdc SRD, 6A/6B auxiliary switch, Metal (block close and open) padlock, No counter - no locks key lock, air circuit breaker
From Get Price
Limited Stock
GM-13.8-500-1200A-MO-6P
GM-13.8-500-1200A-MO-6P
General Electric - Ground & Test Device
GM-13.8-500-1200A-MO-6P, General Electric, Magne-Blast Series, , Manually Operated, 3PH, 6 Bushing Design, 15000 VAC, 1200A Frame, circuit breaker ground & test device, For Use In M-36 Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price
In Stock
DSLII-308-800A-EO-DO
DSLII-308-800A-EO-DO
Cutler Hammer - Air
DSLII-308-800A-EO-DO, Cutler Hammer, DSLII Series, , 3PH, 3P, 600 VAC, 800 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-800 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price
Limited Stock
LA-25-360A-MO-DO
LA-25-360A-MO-DO
Allis Chalmers - Air
LA-25-360A-MO-DO, Allis Chalmers, LA Series, , 3PH, 3P, 600 VAC, 360 Frame, Manually Operated, Draw-Out, Low Voltage air circuit breaker, 15A-360 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price
Limited Stock
AKR-8D-100-EO-DO-LSG
AKR-8D-100-EO-DO-LSG
General Electric - Air
AKR-8D-100-EO-DO-LSG, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 4000A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with Epic MicroVersa Trip Solid State Overcurrent Protection, LSG - Long-Time, Short-Time and Ground Fault trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
Limited Stock
AKR-7B-75-EO-DO-LI
AKR-7B-75-EO-DO-LI
General Electric - Air
AKR-7B-75-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 3200A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with MicroVersa Trip RMS-9 Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
Limited Stock
DS-416S-1600A-EO-DO
DS-416S-1600A-EO-DO
Westinghouse - Air
DS-416S-1600A-EO-DO, Westinghouse, DS Series, , 3PH, 3P, 600 VAC, 1600 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-1600 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price
In Stock
S131N
S131N
Square D - Trip Units And Programmers
S131N, Square D, Merlin Gerin, Schneider Electric, Micrologic, field installable Micrologic standard 3.0 trip unit with LI - Long-Time and Instantaneous trip functions, with type 'N' rating plug - which means the rating plug is not included with the trip unit, suitable for NS,NT,NW,PG,PJ,PK,PL,RG,RJ,RK,RL molded case & insulated case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From $230.55
In Stock
S173B
S173B
Square D - Trip Units And Programmers
S173B, Merlin Gerin, Schneider Electric, Square D, Micrologic, field installable Micrologic standard 5.0H trip unit, features LSI - Long-Time, Short-Time and Instantaneous trip functions, metering, advanced protection & harmonic analysis, with type 'B' rating plug, suitable for use with N, P & R frames - NS,NT,NW,PG,PJ,PK,PL,RG,RJ,RK,RL molded case & insulated case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From $418.29
In Stock
S173A
S173A
Merlin Gerin - Trip Units And Programmers
S173A, Square D, Merlin Gerin, Schneider Electric, Micrologic, field installable Micrologic standard 5.0H trip unit, features LSI - Long-Time, Short-Time and Instantaneous trip functions, metering, advanced protection & harmonic analysis, with type 'A' rating plug, suitable for use with N, P & R frames - NS,NT,NW,PG,PJ,PK,PL,RG,RJ,RK,RL molded case & insulated case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From $3,050.32
Limited Stock
SSPB-4000-4000A-EO-DO
SSPB-4000-4000A-EO-DO
Sylvania - Air
SSPB-4000-4000A-EO-DO, Sylvania, SSPB Series, , 3PH, 3P, 600 VAC, 4000 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-4000 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price
Limited Stock
GM-4.16-250-1200-2000A-EO-3P
GM-4.16-250-1200-2000A-EO-3P
General Electric - Ground & Test Device
GM-4.16-250-1200-2000A-EO-3P, General Electric, Magne-Blast Series, , Electrically Operated, 3PH, 3 Bushing Design, 5000 VAC, A Frame, circuit breaker ground & test device, For Use In M-26 Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price