DMB-50-1600A-MO-BO
Federal Pacific - Air
DMB-50-1600A-MO-BO, Federal Pacific, DMB Series, , 3PH, 3P, 600 VAC, 1600 Frame, Manually Operated, Bolt-On, Low Voltage air circuit breaker, 15A-1600 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

DSLII-516-1600A-EO-DO
Cutler Hammer - Air
DSLII-516-1600A-EO-DO, Cutler Hammer, DSLII Series, , 3PH, 3P, 600 VAC, 1600 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-1600 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

AKR-10S-50-EO-BI-LI
General Electric - Air
AKR-10S-50-EO-BI-LI, General Electric, Electrically Operated, Bolt-In, Low Voltage air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with MicroVersa Trip Plus - Gen 2 Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

LK-20-2000A-EO-DO
BBC - Air
LK-20-2000A-EO-DO, BBC, LK Series, , 3PH, 3P, 600 VAC, 2000 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-2000 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

DS-632-3200A-EO-DO
Square D - Air
DS-632-3200A-EO-DO, Square D, DS Series, , 3PH, 3P, 600 VAC, 3200 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-3200 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

AKRU-8D-30S-EO-DO-LSG
General Electric - Air
AKRU-8D-30S-EO-DO-LSG, General Electric, Electrically Operated, Draw-out, Low Voltage Fused air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with Epic MicroVersa Trip Solid State Overcurrent Protection, LSG - Long-Time, Short-Time and Ground Fault trip functions, Optional Trip Functions, Current Sensor, Rating Plug and Fuse Amperages available
From Get Price

KB-200A-EO-DO
ITE - Air
KB-200A-EO-DO, ITE, KB Series, , 3PH, 3P, 600 VAC, 200 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-200 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

MDS8203WEA1652CNAN6YPNNAX
Eaton - Insulated Case
MDS8203WEA1652CNAN6YPNNAX, Cutler Hammer, Eaton, Magnum DS Type , Standard frame, 85kA@635V interrupting rating, 2000A, 3-Pole, Drawout mounting, 1600A rating plug, Non-DSL current limiter, 520 LSI trip unit, 24 Vdc shunt trip, 110-125 Vac (5-sec) motor operator, 110-127 Vac/Vdc SRD, No, 6A/6B auxiliary switch, Plastic (block close and open) padlock, No counter - no lock key lock, low voltage power insulated case circuit breaker
From Get Price

2601D39G13
Westinghouse - Rating Plug
2601D39G13, Westinghouse, Cutler Hammer, SELTRONIC,Series C, type , fixed rating plug element, rated for 700A, suitable for use with 800A Seltronic - MC,MCA,MCG,MCGA,HMC,HMCA,HMCG,HMCGA,MCC,MCCA,HMCC,HMCCA,MCCGA,HMCCG,HMCCGA,MDS,MDSY,MDSC molded case circuit breaker frame types, for use with Seltronic solid state electronic trip units & circuit breakers; these rating plugs are obsolete; however we do still stock them
From Get Price

LA-50A-1600A-MO-DO
Allis Chalmers - Air
LA-50A-1600A-MO-DO, Allis Chalmers, LA Series, , 3PH, 3P, 600 VAC, 1600 Frame, Manually Operated, Draw-Out, Low Voltage air circuit breaker, 15A-1600 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

LA-50A-1600A-EO-DO
Allis Chalmers - Air
LA-50A-1600A-EO-DO, Allis Chalmers, LA Series, , 3PH, 3P, 600 VAC, 1600 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-1600 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

GMT-MAN-2-6-1200-2000-3000A-EO-6P
Siemens - Ground & Test Device
GMT-MAN-2-6-1200-2000-3000A-EO-6P, Siemens, GMI Series, , Electrically Operated, 3PH, 6 Bushing Design, 15000 VAC, A Frame, circuit breaker ground & test device, For Use In GM Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price

MDS8403WEA4052ANAN4YHANAX
Eaton - Insulated Case
MDS8403WEA4052ANAN4YHANAX, Cutler Hammer, Eaton, Magnum DS Type , Standard frame, 85kA@635V interrupting rating, 4000A, 3-Pole, Drawout mounting, 4000A rating plug, Non-DSL current limiter, 520 LSI trip unit, 110-127 Vac/Vdc shunt trip, 110-125 Vac (5-sec) motor operator, 110-127 Vac/Vdc SRD, No, 4A/4B auxiliary switch, Plastic (block close only) padlock, Counter - no lock key lock, low voltage power insulated case circuit breaker
From Get Price

8MC800
Cutler Hammer - Rating Plug
8MC800, Cutler Hammer, Westinghouse, SELTRONIC,Series C, type , fixed rating plug element, rated for 800A, suitable for use with 800A Seltronic - MC,MCA,MCG,MCGA,HMC,HMCA,HMCG,HMCGA,MCC,MCCA,HMCC,HMCCA,MCCGA,HMCCG,HMCCGA,MDS,MDSY,MDSC molded case circuit breaker frame types, for use with Seltronic solid state electronic trip units & circuit breakers; these rating plugs are obsolete; however we do still stock them
From $248.47

MWI6203HEA2052ANAN4EPNNAX
Eaton - Air
MWI6203HEA2052ANAN4EPNNAX, Eaton, Cutler Hammer, Magnum IEC Type , Standard frame, 65kV@690V interrupting rating, 2000A, 3-Pole, Fixed Horizontal mounting, 2000 rating plug, {current limiter} current limiter, 520 LSI trip unit, 110-127 Vac/Vdc shunt trip, 110-125 Vac (5-sec) motor operator, 110-127 Vac/Vdc SRD, 4A/4B auxiliary switch, Plastic (block close and open) padlock, No counter - no locks key lock, air circuit breaker
From $8,811.29

8MC600
Westinghouse - Rating Plug
8MC600, Westinghouse, Cutler Hammer, SELTRONIC,Series C, type , fixed rating plug element, rated for 600A, suitable for use with 800A Seltronic - MC,MCA,MCG,MCGA,HMC,HMCA,HMCG,HMCGA,MCC,MCCA,HMCC,HMCCA,MCCGA,HMCCG,HMCCGA,MDS,MDSY,MDSC molded case circuit breaker frame types, for use with Seltronic solid state electronic trip units & circuit breakers; these rating plugs are obsolete; however we do still stock them
From $119.06

8MC500
Westinghouse - Rating Plug
8MC500, Westinghouse, Cutler Hammer, Series C,SELTRONIC, type , fixed rating plug element, rated for 500A, suitable for use with 800A Seltronic - MC,MCA,MCG,MCGA,HMC,HMCA,HMCG,HMCGA,MCC,MCCA,HMCC,HMCCA,MCCGA,HMCCG,HMCCGA,MDS,MDSY,MDSC molded case circuit breaker frame types, for use with Seltronic solid state electronic trip units & circuit breakers; these rating plugs are obsolete; however we do still stock them
From $215.53

DMB-50-TMS-800A-MO-DO
Federal Pacific - Air
DMB-50-TMS-800A-MO-DO, Federal Pacific, DMB Series, , 3PH, 3P, 600 VAC, 800 Frame, Manually Operated, Draw-Out, Low Voltage air circuit breaker, 15A-800 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

K-225-225A-MO-BO
ITE - Air
K-225-225A-MO-BO, ITE, K-Line Series, , 3PH, 3P, 600 VAC, 225 Frame, Manually Operated, Bolt-On, Low Voltage air circuit breaker, 15A-225 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In K-Line Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

AK-2A-75-3000A-MO-DO
General Electric - Air
AK-2A-75-3000A-MO-DO, General Electric, AK Series, , 3PH, 3P, 600 600, 3000 Frame, Manually Operated, Draw-Out, Low Voltage air circuit breaker, 15A-3000 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models For Use In AKD-5 Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

AKJU-5A-50-1600A-MO-DO
General Electric - Air
AKJU-5A-50-1600A-MO-DO, General Electric, AKJ Series, , 3PH, 3P, 600 VAC, 1600 Frame, Manually Operated, Draw-Out, Low Voltage air circuit breaker, 15A-1600 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In AKD-5 Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

AK-2-75-3000A-MO-BO
General Electric - Air
AK-2-75-3000A-MO-BO, General Electric, AK Series, , 3PH, 3P, 600 600, 3000 Frame, Manually Operated, Bolt-On, Low Voltage air circuit breaker, 15A-3000 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models For Use In AKD Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

AKR-5C-75-3200A-MO-DO
General Electric - Air
AKR-5C-75-3200A-MO-DO, General Electric, AKR Series, , 3PH, 3P, 600 VAC, 3200 Frame, Manually Operated, Draw-Out, Low Voltage air circuit breaker, 15A-3200 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In AKD-6 Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

AKU-7-25-600A-MO-DO
General Electric - Air
AKU-7-25-600A-MO-DO, General Electric, AKU Series, , 3PH, 3P, 600 VAC, 600 Frame, Manually Operated, Draw-Out, Low Voltage air circuit breaker, 15A-600 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In AKD-5 Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price