


- Home /
breaker
911,476 Results
Refine Results
In Stock
Subcategory
SORT BY

MDN4083LEA0822NMNFNYNCNCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNFNYNCNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

SHD3G6Y1U
General Electric - Insulated Case
SHD3G6Y1U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, modbus communication, relays & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

MDN4083LEA0222NMNFNENCCCX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNFNENCCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0122NMNN2YNADSX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNN2YNADSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

K550LIGDZ1R
General Electric - Trip Units And Programmers
K550LIGDZ1R, General Electric, MicroVersaTrip Plus, replacement trip units and programmers, 5000A current sensor rating, Solid State electronic, LIG - Long-Time, Instantaneous and Ground Fault trip functions, defeatable ground fault, ground fault zone-selective interlock, suitable for use with 5000A frame WavePro WPS,WPH,WPF,WPX low voltage power circuit breakers
From Get Price

SEHF361200LIES2E4
Square D - Insulated Case
SEHF361200LIES2E4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1200A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 24VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

SEHF362500LSGES8E8
Square D - Insulated Case
SEHF362500LSGES8E8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 2500A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

TPSS6610G3
General Electric - Insulated Case
TPSS6610G3, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 1000A, 100kA@480V, standard interrupting capacity, with ground fault protection, 3-phase, 3-wire, Feed-Thru, for use with VersaTrip programmers, LI - Long-Time and Instantaneous trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price

MDN4083LEA0122NMNN4ENHCWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNN4ENHCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

1764663
Eaton - Trip Units And Programmers
1764663, Eaton, Naval, Thermal Magnetic trip units and programmers, type -A100, 3P, 50A, 500Vac, 600-700 instantaneous trip setting, LI - Long-Time and Instantaneous trip functions, suitable for use with AQB-A100,NQB-A100 circuit breakers for naval shipboard use
From Get Price

SEHD361400LSGES5D5
Schneider Electric - Insulated Case
SEHD361400LSGES5D5, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1400A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 24VDC shunt trip along with AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

SHB1G2Y7H
General Electric - Insulated Case
SHB1G2Y7H, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, modbus communication, relays & ZSI features and 400A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

MDN4083LEA0622NMNG2NNKCAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNG2NNKCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

MP40-3P-2500A-EO-BO-LSG
Merlin Gerin - Insulated Case
MP40-3P-2500A-EO-BO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 4000A frame includes 2500A, 3000A, 3200A or 4000A sensor rating with 2500A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

PKL26000S60BD
Schneider Electric - Molded Case
PKL26000S60BD, Square D, Schneider Electric, PowerPact, type , 2P, 1PH, 600A, 600V, 50kA@480V, UL listed, high interrupting capacity, Feed-Thru, complete with 1A/1B overcurrent trip switch, NA - No Overcurrent Protection, Non-Automatic switch, line & load side lug terminals, molded case circuit breakers
From Get Price

MDN4083LEA0322NMNRNNNCNCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNRNNNCNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0122NMNC2NNANCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNC2NNANCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MN4L2W20
General Electric - Insulated Case
MN4L2W20, General Electric, M-PACT Plus, type , frame size 2, manually operated, with cassette and 5 N.O.-3 N.C. Auxiliary switch, 4P, 3PH, left side neutral, 2000A, 690V, 65kA@415V, Draw-Out, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers
From Get Price

MDN4083LEA0222NMNF4NNYCSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNF4NNYCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

SED36250LIGC4
Schneider Electric - Insulated Case
SED36250LIGC4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 250A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, complete with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

SSF4G6A6N
General Electric - Insulated Case
SSF4G6A6N, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering & RELT features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

MDN4083LEA0622NMNK4NNHCAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNK4NNHCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

PEDB4ATAM0150
General Electric - Molded Case
PEDB4ATAM0150, General Electric, GuardEon, type , 3PH, 4P, 600V, 45-150A, 18kA@480V, front connection/Feed-Thru, toggle mechanism, complete with PremEon G interchangeable trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions with switchable GF, Solid State electronic, molded case circuit breakers; meet UL, cUL, IEC, CE, CCC requirements
From Get Price

MDN4083LEA0522NMNN2YNYCWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNN2YNYCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price