1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
PKF46040CU44AAB
PKF46040CU44AAB
Square D - Molded Case
PKF46040CU44AAB, Square D, Schneider Electric, PowerPact, type , 4P, 3PH, 400A, 600V, 50kA@480V, UL listed, high interrupting capacity, Bolt-On, 100% rated, complete with 2A/2B auxiliary switch, micrologic interchangeable ammeter 6.0A trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNA4NNHMPX
MDN4083LEA0222NMNA4NNHMPX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNA4NNHMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
65H-3-1600A-EO-BO-LS
65H-3-1600A-EO-BO-LS
Federal Pioneer - Air
65H-3-1600A-EO-BO-LS, Federal Pioneer, H-3 Series, type , 1600A frame size, electrically operated/Bolt-On, 3P, 3PH, 1600A, 600V, 65kA@480V, available with multiple trip unit options, LS - Long-Time and Short-Time trip functions, Solid State electronic, low voltage power air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNNNENLMWX
MDN4083LEA0822NMNNNENLMWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNNNENLMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, latch check switch for external wiring, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, operations counter, Castell keylock, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassette, with shutters and pre-wired
From Get Price
Limited Stock
MDN4083LEA0122NMNC2ENCDPX
MDN4083LEA0122NMNC2ENCDPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNC2ENCDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
In Stock
HJA36040AEBHUHYP
HJA36040AEBHUHYP
Square D - Molded Case
HJA36040AEBHUHYP, Square D, PowerPact, type , 3PH, 3P, ABC phase connection, 40A, 600V, 65kA@480V, current limiting, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with 1A/1B low-level aux switch, alarm switch low-level, 380/480 VAC under voltage release (UVR), "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $2,130.87
Limited Stock
MDN4083LEA0322NMNNNYNKCWX
MDN4083LEA0322NMNNNYNKCWX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNNNYNKCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0822NMNKNYNLNCX
MDN4083LEA0822NMNKNYNLNCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNKNYNLNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch, & Castell key interlock, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0822NMNKNNNLDWX
MDN4083LEA0822NMNKNNNLDWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNKNNNLDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions,load side lug terminals, mechanical trip indicator, Castell key interlock & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0122NMNANYNLCCX
MDN4083LEA0122NMNANYNLCCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNANYNLCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SEHD36250LSIGES1D8
SEHD36250LSIGES1D8
Schneider Electric - Insulated Case
SEHD36250LSIGES1D8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 250A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & shunt trip along with 4A4B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SHB1G2B8B
SHB1G2B8B
General Electric - Insulated Case
SHB1G2B8B, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering, RELT & modbus communication features and 150A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
PGL36040CU31BRD10
PGL36040CU31BRD10
Schneider Electric - Molded Case
PGL36040CU31BRD10, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 400A, 600V, 35kA@480V, UL listed, standard interrupting capacity, Feed-Thru, 100% rated, complete with direct mounted standard black handle, micrologic interchangeable standard 3.0 trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
HLK260901
HLK260901
Schneider Electric - Molded Case
HLK260901, Schneider Electric, Square D, PowerPact, type , 2P, A & B phase connection, 1PH, 90A, 600V, 100kA@480V, UL listed, current limiting, reverse I-Line Style Plug-In, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
WLS2F316RG
WLS2F316RG
Siemens - Insulated Case
WLS2F316RG, Siemens, WL Series, type , frame size II, fixed mount, 3P, 3PH, 1600A, 600V, 65kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with solid state ETU745 programmer + WLGFM48 ground fault module, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and 1250A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
1MHCB400RC
1MHCB400RC
Cutler Hammer - Panel Board
1MHCB400RC, Cutler Hammer, Series C, type , panel board, 1-phase, 3-wire, main 400A rated, 120/240Vac, Main Breaker, bottom feed, Copper bus, to be used with HKD main circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNKNYNHNAX
MDN4083LEA0422NMNKNYNHNAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNKNYNHNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
PDG32FH250D5DK
PDG32FH250D5DK
Cutler Hammer - Molded Case
PDG32FH250D5DK, Cutler Hammer, Eaton, Power Defense, type , 600A frame, 1PH, 2P, 600V, 250A, high override, 25kA@480V, Bolt-On, line side lug terminals, complete with PXR20D ARMS trip with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and Modbus RTU, CAM link & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
SSB4G6B6M
SSB4G6B6M
General Electric - Insulated Case
SSB4G6B6M, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering, RELT & modbus communication features and 750A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0622NMNGNNNKCCX
MDN4083LEA0622NMNGNNNKCCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNGNNNKCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0622NMNANENANWX
MDN4083LEA0622NMNANENANWX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNANENANWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SEF363200LSIGES5A4
SEF363200LSIGES5A4
Schneider Electric - Insulated Case
SEF363200LSIGES5A4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 3200A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 24VDC shunt trip along with 2A2B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
E1B-A12-3P-1000A-BO-EO-LI
E1B-A12-3P-1000A-BO-EO-LI
ABB - Insulated Case
E1B-A12-3P-1000A-BO-EO-LI, ABB, EMax, type , 3P, 3PH, 1200A frame, 1000A rating plug, 600V, 42kA@480V, fixed/Bolt-On, electrically operated, Solid State electronic with LI - Long-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SSD1G114A
SSD1G114A
General Electric - Insulated Case
SSD1G114A, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, RELT & ZSI features and 100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price