Limited Stock
MDN4083LEA0722NMNR4NNYNAX
MDN4083LEA0722NMNR4NNYNAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNR4NNYNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
EF3M070L
EF3M070L
ITE - Molded Case
EF3M070L, Siemens, ITE, EF Series, type , 3P, 3PH, 70A, 600V, 14kA@480V, standard interrupting capacity, Feed-Thru, marine duty rated, 50°C, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, molded case circuit breakers; these breakers are now obsolete, however we do still stock them
From Get Price
Limited Stock
SEHD361200LSGC4
SEHD361200LSGC4
Schneider Electric - Insulated Case
SEHD361200LSGC4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1200A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, complete with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0622NMNC4ENLCPX
MDN4083LEA0622NMNC4ENLCPX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNC4ENLCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MGP26500
MGP26500
Schneider Electric - Molded Case
MGP26500, Schneider Electric, Square D, PowerPact, type , 2P, 1PH, 500A, 600V, 35kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with basic non-interchangeable 1.0 trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
S204-K8
S204-K8
ABB - Molded Case
S204-K8, ABB, S 200 Series, type , 4P, 3PH, 8A, 480V, 6kA@480V, standard interrupting capacity, current limiting, DIN rail mounted, Feed-Thru, suitable for reverse feed, UL/CSA/IEC approval, branch circuit protection, K trip characteristic, Thermal Magnetic trip functions, Thermal Magnetic, miniature molded case circuit breakers and supplemental protectors
From Get Price
Limited Stock
PJF36120CU73BE1AB
PJF36120CU73BE1AB
Schneider Electric - Molded Case
PJF36120CU73BE1AB, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 1200A, 600V, 65kA@480V, UL listed, high interrupting capacity, Bolt-On, 100% rated, complete with 2A/2B auxiliary switch, micrologic interchangeable harmonic 5.0H trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
EGH3070FFGVH08
EGH3070FFGVH08
Cutler Hammer - Molded Case
EGH3070FFGVH08, Cutler Hammer, Series G, type , 3P, 3PH, 70A, 600V, 65kA@480V, high interrupting capacity, for Marine applications 50°C, not UL listed, Feed-Thru, complete with non-interchangeable trip unit and line & load side lug terminals, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
E4H-A32-4P-2000A-BO-MO-LSIG
E4H-A32-4P-2000A-BO-MO-LSIG
ABB - Insulated Case
E4H-A32-4P-2000A-BO-MO-LSIG, ABB, EMax, type , 4P, 3PH, 3200A frame, 2000A rating plug, 600V, 85kA@480V, fixed/Bolt-On, manually operated, Solid State electronic with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
PDG64M2000P2MM
PDG64M2000P2MM
Eaton - Molded Case
PDG64M2000P2MM, Eaton, Cutler Hammer, Power Defense, type , 3PH, 4P, 600V, 2000A, 65kA@480V, Bolt-On, no terminals with metric tapped conductors, complete with PXR25 trip with LSI - Long-Time, Short-Time and Instantaneous trip functions with relays and modbus option, Solid State electronic, molded case circuit breakers; globally rated
From Get Price
Limited Stock
MDN4083LEA0622NMNANENACSX
MDN4083LEA0622NMNANENACSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNANENACSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SEHD361800LSES2E5
SEHD361800LSES2E5
Square D - Insulated Case
SEHD361800LSES2E5, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1800A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 24VDC spring charging motor, shunt closing coil & shunt trip along with AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
PDG53P0800P5YM
PDG53P0800P5YM
Eaton - Molded Case
PDG53P0800P5YM, Cutler Hammer, Eaton, Power Defense, type , 3PH, 3P, 600V, 800A, 100kA@480V, Bolt-On, no terminals with metric tapped conductors, complete with PXR25 trip with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip with ARMS functions with relays, modbus, ZSI & CAM option, Solid State electronic, molded case circuit breakers; globally rated
From Get Price
Limited Stock
MDN4083LEA0322NMNG4NCKNCX
MDN4083LEA0322NMNG4NCKNCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNG4NCKNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Kirk keylock, 4A/4B auxiliary switch, mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MGL36700UL
MGL36700UL
Square D - Molded Case
MGL36700UL, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 700A, 600V, 35kA@480V, UL listed, high interrupting capacity, Feed-Thru, complete with 48Vac UVR, basic non-interchangeable 1.0 trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
XT5HQ450BNFF000XXX
XT5HQ450BNFF000XXX
ABB - Molded Case
XT5HQ450BNFF000XXX, ABB, SACE Tmax XT, type , UL 100% rated, 3PH, 4P, 600V, 500A, 65kA@480V, Bolt-On, front terminals, complete with TMG trip, generator protection circuit breakers; 1SDA102653R1 + 1SDA112974R1 global reference
From Get Price
Limited Stock
SHB1G2K9H
SHB1G2K9H
General Electric - Insulated Case
SHB1G2K9H, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering & ZSI features and 400A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
AKR-4B-50H-EO-DO-LI
AKR-4B-50H-EO-DO-LI
General Electric - Air
AKR-4B-50H-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with SST Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
Limited Stock
LA-4000B-MO-DO-LS
LA-4000B-MO-DO-LS
Siemens-Allis - Air
LA-4000B-MO-DO-LS, Siemens-Allis, LA Series, type , 4000A frame size, manually operated/Draw-Out, 3P, 3PH, 4000A current sensor rating, 600V, 85kA@480V, originally supplied with StaticTrip II or LimiTrip overcurrent trip devices but can also be retrofitted with a modern Solid State electronic trip unit with LS - Long-Time and Short-Time trip functions, low voltage power air circuit breakers
From Get Price
In Stock
HLA36070AEBEUOYP
HLA36070AEBEUOYP
Square D - Molded Case
HLA36070AEBEUOYP, Square D, PowerPact, type , 3PH, 3P, ABC phase connection, 70A, 600V, 100kA@480V, current limiting, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with 1A/1B low-level aux switch, alarm switch and overcurrent trip switch, 24 VDC under voltage release (UVR), "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $2,782.50
Limited Stock
SEHF361200LSIGES9
SEHF361200LSIGES9
Square D - Insulated Case
SEHF361200LSIGES9, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1200A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & 24VDC shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SED364000ET2
SED364000ET2
Schneider Electric - Insulated Case
SED364000ET2, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 4000A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 24VDC spring charging motor, shunt closing coil & shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
PDG33N0300VFAL
PDG33N0300VFAL
Eaton - Molded Case
PDG33N0300VFAL, Eaton, Cutler Hammer, Power Defense, type , 3PH, 3P, 600V, 300A, 85kA@480V, Bolt-On, load side lug terminals, complete with LI - Long-Time and Instantaneous trip functions, 50ºC Thermal Magnetic, molded case circuit breakers; CSA, IEC, UL, CCC certifications; non-UL listed
From Get Price
Limited Stock
PLF34120CU64AE1AC
PLF34120CU64AE1AC
Schneider Electric - Molded Case
PLF34120CU64AE1AC, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 1200A, 480V, 100kA@480V, UL listed, very high interrupting capacity, Bolt-On, 100% rated, complete with 3A/3B auxiliary switch, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price